Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Eprocure
Opening Date12 Feb 2024
Closing Date28 Feb 2024
Tender Amount₹ 21,03,917 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
d) 90 mm dia.

750

256500

342

... More
Providing FHTC from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline installing 10 mm NB Gun-metal Ferrule conforming to IS2692:1989 with latest amendments of the said pipeline with supply fitting & fixing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of l5mm NB PVC (Schedule80)/20mm OD HDPE {PE100, PN16)/20mm OD PPR-C {Ctass - SDR7.4/PN16} pipes upto required length with all necessary specials 1.0 metre below the ground connecting including cutting trenches in all sorts of soil and filling up trenches'as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by EiC. Supply and installation of a l5mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. frorn ground, an alloy stop cock of 15 with brass spindle (tested ta 21" Kg/cm2] to be fitted in a position as directed by EIC G.l pipe of TATA make {mediurn duly} of 2 metre length with all necessary continue from the end of the PVC/HDPE/PPR-C pipe and upto 1.0 m above ground within the premises of household. Note: 1. PVC pipe shall of schedule 80 (medium duty) conlorming to ASTMD -1785 and threaded to match with Gl Pipes as per IS : 1239 (Part - I). 2. PPR'C (Poly propylene Randam copolymer) pipe shofi be 3-layer confirming to IS:15801 UV stabilised & anti-microbial fusion welded, having thermal stabitity for hot & cold water supply including all PP-R plain & brass threoded polypropylene random/fittings. 3. Rate is exclusive of supply and delivery of 10mm NB gun-metal Ferrule. Supply & laying of 15 mm NB PVC (Schedule80)/20 mm OD HDPE (PE100, PN16)/20MM OD PPR-C (cLASS-SDR7.4/PN16) pipes a) Upto 10 m length

195

365430

1874

... More
b) Above 10 m upto 20m length

195

593580

3044

... More
Collection of Household details as per prescribed format through Mobile app/Hard copies including Geo referance as diected by E.I.C and submission of the same to the P.H.E Dte. in soft copies.

390

10920

28

... More
Construction of different dia Sluicevalve/Airvalve/Washoutchamberin different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] a) 80 mm. to 150 mm. dia.

2

23608

11804

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m In ground floor including roof. (b) Upto 150 mm. Thick

25

23475

939

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. Pakur Variety

25

113909

4556.38

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). B) For UPVC/HDPE Pipe a) 50 mm dia

500

1460

2.92

... More
b) 63mm dia

500

1565

3.13

... More
c) 75mm dia

750

2362

3.15

... More
d) 90 mm dia.

750

2700

3.6

... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). B) For UPVC/HDPE Pipe a) 50 mm dia

500

345

0.69

... More
b) 63mm dia

500

345

0.69

... More
c) 75mm dia

750

517

0.69

... More
d) 90 mm dia.

750

660

0.88

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.

2500

950

0.38

... More
Add GST @18% on sum of Item No. 1 to 19

1

317758

317758.95

... More
Add Cess @1% on sum of Item No. 1 to 20

1

20830

20830.86



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.