Public Health Engineering Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date18 Jul 2024
Closing Date9 Aug 2024
Tender AmountRefer Documents
Costs
EMD
₹ 45,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbphed/ee/bmd/niet- 4 Of 2024-2025/6
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_702966_6Bid Award Id
ViewTender No
WBPHED/EE/BMD/NIeT- 4 OF 2024-2025Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://www.wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.5 mtr long
4
-
-
3 mtr long
20
-
-
Supply and delivery at site 80 mm dia CI Top Adaptor with flange (Single clamp)
2
-
-
Supply and delivery at site 80 mm dia CI Bottom Adaptor (Single clamp)
2
-
-
Supply and delivery of 415 V MCC cum PDB with minimum 2 mm thickness and degree of protection IP-54 ,conforming to IS- 8623 with suitable Busbar ,Digital Voltmeter,Ammeter, ,contactor , delay timer ,MCB, valve actuator stater with PLC logic & UPS . i)7.5-12.5 HP with SDS starter according to preset time as per direction and technical specification given in NIeT
For Betanal Zone -B boosting TW site
N.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel.
1
-
-
Supply , delivery Oil cooling type voltage stabilizer 20 KVA having unbalance 200-500 V input voltage and 415 (±1%) output voltage ,auto/ manual servo voltage stabilizer with O/V,U/V,O/L protection with contactor at out put side ,input MCB ,Ammeter bell, etc as per I.E rules and as per technical specification given in NIT.
For,i) Boosting –I
Make- As per PHE approved vendor list
1
-
-
Supply delivery and storage at site of 80 mm dia Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicator as per technical specification
1
-
-
Supply, delivery at site of following items
-
-
-
Supplying delivery of 100 Amps 415 Volt TPN Sheet steel enclosed re-wireable fuse type Main Switche with side handle operated.
2
-
-
Supplying delivery of 100 Amps 415 Volt TPN Sheet steel enclosed Onload Changeover Switch side handle operated.
1
-
-
Supply and fitting fixing of wall mounted 415 Volt TPN sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required i)100 Amp 4way
1
-
-
Supply and delivery of following valves
-
-
-
80 mm dia CIDF single door swing check Non Return valve(P.N-1.0) generally conforming to IS 5312 Part I for delivery line and as per technical Specification given in NIT.
1
-
-
80mm dia CIDF non-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846 and as per technical Specification given in NIT .
(for 1 no by pass arrangement )
2
-
-
Supply, delivery and storage at site of following cables
-
-
-
4 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date.
200
-
-
35mm2 3.5Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,
(From WBSEDCL meter to MCC & through Voltage stabilizer)
100
-
-
25mm2 3Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,
(From MCC meter to out door Kiosk Box)
2nos T/W x 100 mtr =200mtr
200mtr x 2nos Cable=400mtr
400
-
-
Supply ,delivery and automatically controlled planger type chlorinator dosing pump with Flow Rate 0-100 ltr/Hr and Max pressure 10kg/cm2 with all relive valve and diaphgram rupture indicator ,pressure gauge ,parure switch, base plate, flexible coupling guard for pump and motor, foundation bolt, dosing solution, of 100 ltr capacity and the prime mover to be coupled with pump of 0.5 HP 3 phase 1440 RPM (±4%) squirrel cage TEFC induction Motor ,motor will be IE3.
make-As per PHE approved vendor list
1
-
-
Installation of the above PLC automatic panel with chlorinator and voltage stabilizer by necessary jointing materials and interconnection of the sub – cable and power cable with outdoor type actuator with cable protection pipe and specials including necessary brick works, plastering,Net fencing of serounding area etc as per direction of E.I.C
1
-
-
Making double Earthing arrangement in complience with I.E rules by G.I pipe electrode with G.I funnel(50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete.
4
-
-
Laying of two nos 25 sqmm 3 core Al, Ar Cable in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
200
-
-
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
40
-
-
Making internal wiring /electrification of Pump House by 2x 22/0.3(1.5DSq mm + 1x 22/0.3(1.5sqmm) single core PVC insulated multistranded FRLSH grade flexible copper wire through 20mm PVC conduit pipe/cashing by supplying one no 40Amp, 10KA , 240/415V , 50HZ, SPN/DP MCB isolator conforming to IS/IEC:60947-3, C characterise / As per approved vendor list of PHED vide no-PHE/IV/2277/W-181/19 dated-25-09-21 with required model PVC Board & Piano key type switch (Avg Run 6mtr). i) LED Tube Set point-2nos, Bulk Head light point-1no each with necessary earthing arrangement & one fan point(Total point 6nos)including drawing power DB through 20mm PVC cashing caping (precision make) as per direction of EIC(fitting cut-out to SPN/DP MCB wiring should be with continuous earthing arrangement and 20W two no’s x 4ft long LED tube light make-Philips, Bulk Head light M.No- Endra WT202W LED6S NW PSU S2 PC one nno 0.4 Stap fan regulator fitting etc to be supplyed by agency
1
-
-
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over 150mm. thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]
i) DN-80 mm dia
for Above Flow meter
1
-
-
Arrangement for Double tank Chlorine dosing system
-
-
-
Supply, delivery at site of following items for i) 100 liter FRP conical type tank 6mm thickness make GP resin & vinyle ester resin tank with led
ii) 0.25 H.P Motor 1440 rpm gear 960 rpm
iii) FRP shaped with propeller (blade) iv) ½” Y Stainer (PP) v) ½” inlet outlet pipe line. vi) 1” sludge outlet line. vii) level indicator
2
-
-
Supply and delivery of following PVC items
-
-
-
PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).
i) 25mm dia
20
-
-
25 mm dia G.I Supply of long screw (150 mm long) of TATA make with sockets (TATA make) and jamnut.
2
-
-
25 mm dia G.I. socket with ISI mark
2
-
-
25mm dia union (PVC)
4
-
-
25mm dia elbow (PVC)
6
-
-
25mm dia ball UPVC valve
4
-
-
Supply and delivery of (35mmx 35mm x 6 mm) M.S Iron angle frame up to height 1.5mtr for installation of 100ltr capacity Hypoclride solution mixed with water (fracture weight 41kg approx)
2
-
-
Installtion of above items with newly supplied matrials including necessary fitting fixing matrials as per direction of E.I.C
2
-
-
Supply and delivery of safety equipment like Rubber Mat, fire extenguser, hand gloves etc as per technical specification given in NIT
1
-
-
Supply and delivery of 2(Two) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT
1
-
-
Cost of supply and delivery at site of calcium hypochlorite granule minimum CI content 60%-65% in air plastic jar (3kg each) as per direction of EIC. (Make PHE approved)
300
-
-
Trial run of pumping machinery, through PLC / Automatic panel also operation of Chlorinator, V.S etc. including operation of rising main valve if required and guarding of installation as per direction of E.I.C.(Each T/W for 90 days engaiging 1 personal for each T/W)
1
-
-
Supply of swaged / stepped type steel tubular pole of 9 m long (410‐SP‐26) conformed to IS : 2713-1980. The length of bottom section shall be 5.0 mtr, middle section shall be 2.0 mtr & top of 2.0 mtr. The bottom section of the pole shall be 114.3 x 4.50mm dia, middle section of the pole shall be 88.9 x 4.05 mm dia & the top portion shall be 76.1 x 3.25 dia, 1.5 mtr. long MS bracket made out of 40 mm dia MS pipe shall be fixed on top of the pole for fixing light fiottings. The MS mounting bracket shall be fixed on top of the pole weight approx 92 Kg
Make- Calcutta Pole/India Pole/jindal/Any approved make
N.B- Certificate of Pole from manufacturer should be produce at the time of delivery
-
-
-
a) Single Arm
2
-
-
Supply delivery & fitting fixing of Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.
M.No-BRP409 LED115 CW SLC FG PSU GR V2 of Philips make or equivalent model)
2
-
-
Supply and delivery of 6 sq.mm. 2 core PVC insulated XLPE Ar. AL conductor cable, As Per IS-7098 (Part 1) 2011 with Up To Date Amendment
80
-
-
Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond
1,500 mm. and upto 3,000 mm. but not requiring
shoring.
3
-
-
Erection of Single tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
2
-
-
Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole
2
-
-
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting
250 x 250 x 100mm
2
-
-
Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated HRFR 1.1 kv grade copper flaxible cable
2
-
-
Supply and fitting fixing of 20mm dia GI pipe Medium quality (TATA) from muffing to Joint box
2
-
-
Laying through Underground Trech
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
70
-
-
Laying on Wall / surface with Saddles / clamps
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F M S saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
10
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
For 2 core 6 sqmm cable
4
-
-
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
i) 2 core 6 sqmm cable
4
-
-
Painting of Steel Tubular Pole of lengths and no. of coats of paint,as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
Upto 9.0 mtr. long pole
-
-
-
i) One coat of red lead/Zinc chromate priming
2
-
-
ii) 1st coat of synthetic enamel paint over the primer
2
-
-
ii) 2nd coat of synthetic enamel paint over the 1st coat
2
-
-
Excavation of soil for installation of Earth Electrode and filling & ramming.
i) For Soft Soil
2
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe
2
-
-
a) Supplying and fixing 240/415V MCB Isolator on din rail of existing DBs and necessary connection.
i) 40Amp DP
Make-Havels/L&T/Legrand/Any Approved make
2
-
-
b) Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
A) 16 A (SPN)
Make-Havels
2
-
-
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
a) 2+4 way
Make-Havells Enclosure (DHDPSNODRW04)
2
-
-
Add: 18% GST
1
-
-
Add: 1% Cess
1
-
-