Public Health Engineering Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Electrical and Electronics
Eprocure
Opening Date12 Feb 2025
Closing Date25 Feb 2025
Tender Amount₹ 3,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 100 AMP TP.

2

-

-

... More
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 6 way

1

-

-

... More
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 63 Amps

1

-

-

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
63 Amp DP

6

-

-

... More
40 Amp

4

-

-

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+16 way

2

-

-

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

20

-

-

... More
6-32 A

20

-

-

... More
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wireinside the pipes and fittings and providing 50 mm dia disc ofMS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire(synchronizing with roof/beam casting work of building construction) (i) 19mm dia 3mm thick Polythene Pipe

200

-

-

... More
(ii) 25mm dia 3mm thick Polythene Pipe

20

-

-

... More
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire

200

-

-

... More
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 25 mm dia 3 mm thick polythene pipe without earth continuity wire

20

-

-

... More
Supplying & Fixing CRC sheet metal (16 SWG) JB-cumSwitch Board of the following sizes complete with three no.suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wal housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works

-

-

-

... More
200 mm x 150 mm x 65 mm

5

-

-

... More
175 mm x 100 mm x 65 mm

5

-

-

... More
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works

-

-

-

... More
240 mm x 200 mm x 65 mm

5

-

-

... More
200 mm x 150 mm x 65 mm

5

-

-

... More
150 mm x 100 mm x 65 mm

10

-

-

... More
300 mm x 200 mm x 65 mm

10

-

-

... More
150 mm x 100 mm x 65 mm

10

-

-

... More
100 mm x 100 mm x 65 mm

10

-

-

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box

2

-

-

... More
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required

-

-

-

... More
(i) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC

30

-

-

... More
(ii) 4x84/0.3 (6 sqmm) + 2x56/0.3 (4 sqmm) as ECC

30

-

-

... More
(iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC

50

-

-

... More
(iv) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC

100

-

-

... More
(v) 3 x 22/0.3 (1.5 sqmm)

100

-

-

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC

-

-

-

... More
Average run 6 mtr

20

-

-

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC

-

-

-

... More
On Board

5

-

-

... More
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

10

-

-

... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

20

-

-

... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. for A.C point.

3

-

-

... More
11 Watt,130-320 Volt ,50Hz,0.95 Power factor LED having lumen not less than 1000LMN downlighter suited for office building having Al housing robust PDC housing having Safety class I protection including Spring clip for recess mounting.

20

-

-

... More
32 Watt,Surface Suspended 6500K 32000lm Luminaire white colour.

1

-

-

... More
Fitting fixing of above luminaries as in item no 1.00 on faulse ceiling after cutting the ceiling surface and fixing the same with necessary fixing materials and making necessary inter connection complete as per direction of EIC.

1

-

-

... More
Making double earthing arrangement in compliance with IE rules by G.I. pipe electrode of 5O mm. dia 3 mtr. Long 2 Nos for panel and pumping machinery 25 mm. x 6 mm. G.I. earth strips from earth pit to panel and all other accessories required to complete the work.

1

-

-

... More
N.B.:MAKE: AS PER PHE APPROVED VENDOR LIST AND ADDENDUM/CORRIGENDUM (IF ANY)

-

-

-

... More
Add GST @18%

1

-

-

... More
Add Labour Welfare Cess @ 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.