Public Health Engineering Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Eprocure
Opening Date22 Jan 2025
Closing Soon17 Feb 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Wbphed/ee/amd/ Niet-44 Of 2024-2025/2

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Spreader links - Broadened (with phase barriers) for above MCCB.(Make-Siemens, Type Code-3VA9253-0QC50)

2

-

-

... More
Digital AC Ammeter Input 1A/5A(Programmable), Size-96 mm X 96 mm X 40mm, Display:14 mm LED Display, 3Ph 3W/4W Network, Accuracy Class:-1.0,4 Digit.(Make-Rishabh, Model No-RISH EINEI-EP99/Other Approved make)

6

-

-

... More
Ammmeter selector switch with 4 position indicator, R-Y-B-OFF.(Make-Kaycee, Code No-N3S39AP)

6

-

-

... More
Resin cast C.T., 250A/5A, 10 VA, Class-1.0,(Make-Rishabh, Model No-XRC2(90/50/40).

3

-

-

... More
Digital Voltmeter Input : 100- 500 V L-L (Programmable), Size-96 mm X 96 mm X 40mm, Display:-14 mm LED Display, 3Ph 3W/4W Network,Accuracy Class : 1.0,4 Digit.(Make-Rishabh,Model No-RISH EINE V EP99/Other approved make)

1

-

-

... More
Voltmeter selector switch with 4 position indicator, R-Y-B-OFF.(Make-Kaycee, Code No-N3S39VN)

1

-

-

... More
65 Amp AC-3 rating, 415 V, 50 Hz, Power contactor 220-230 VAC Coil Voltage, with 1 NO & 1 NC Contact.(Make-ABB, Type Code-AX65-30-11)

2

-

-

... More
50 Amp AC-3 rating, 415 V, 50 Hz, Power contactor 220-230 VAC Coil Voltage, with 1 NO & 1 NC Contact.(Make-ABB,Type Code-AX50-30-11)

1

-

-

... More
40 Amp AC-3 rating, 415 V, 50 Hz, Power contactor 220-230 VAC Coil Voltage, with 1 NO & 1 NC Contact.(Make-ABB, Type Code-AX40-30-10)

1

-

-

... More
32 Amp AC-3 rating, 415 V, 50 Hz, Power contactor 220-230 VAC Coil Voltage, with 1 NO Contact.(Make-ABB, Type Code-AX32-30-10)

3

-

-

... More
25 Amp AC-3 rating, 415 V, 50 Hz, Power contactor 220-230 VAC Coil Voltage, with 1 NO Contact.(Make-ABB, Type Code-AX25-30-10)

3

-

-

... More
Over current relay with range 5-60 Amp, locked rotor & phase loss protection with inbuilt display.(Make-BCH, Model No-BOCR DS3 60, Cat No-MP34DS3060S4)

5

-

-

... More
100 Amp, 3 Pole Molded cased circuit breaker with 25 kA breaking capacity, 415 volt, 50 Hz.(Make-ABB, Frame Size-P1 160, Ordering Code-1SDA116235R1)

1

-

-

... More
Direct rotary handle arrangement for above mccb.(Make-ABB, Type-P1, Ordering Code-1SDA116477R1)

1

-

-

... More
Star-Delta Timer, range from 3 sec to 30 sec, 240 - 415 VAC, 1 C/O (Star)+1 C/O (Delta).(Make-L & T, Model No-14SDT1S)

3

-

-

... More
Front mounted single pole 1 NO add-on blocks suitable for AX series power contactor.(Make-ABB, Model No-CA5X-10)

6

-

-

... More
Front mounted single pole 1 NC add-on blocks suitable for AX series power contactor.(Make-ABB, Model No-CA5X-01)

6

-

-

... More
3 Phase Voltage monitoring relay.(Make-Siemens, Type Code-7UG0753-1AA20)

3

-

-

... More
63 Amp, 3 Pole MCB, 415 Volt, 50 Hz.(Make-ABB, Ordering Code-5SL63637RC)

1

-

-

... More
Indication lamp with 230 VAC operating voltage, 50 Hz.(Make-ABB, Type Code-MLBL-07YN/MLBL-07G/MLBL-07R)(Red Coloured-6 Nos, Yellow Coloured-6 Nos, Green coloured-6 Nos)

18

-

-

... More
Indication lamp with 230 VAC operating voltage, 50 Hz.(Make-ABB, Type CodeMLBL-07L)(Blue Coloured-1 No)

1

-

-

... More
Green Coloured, Non-illuminated flush Push-button with black plastic bezel, with 1 NO.(Make:-ABB, Type Code-CP1-10 ¨-10)

5

-

-

... More
Red Coloured, Non-illuminated flush Push-button with black plastic bezel, with 1 NC.(Make:-ABB, Type Code-CP3-10 n-01)

5

-

-

... More
63 Amp, HRC fuses, Conforms to IEC 60269-2,IS 13703 part 2 ,415VAC, 50Hz.(Make:-L & T, Type Code-SF90142)

6

-

-

... More
32 Amp, HRC fuses, Conforms to IEC 60269-2,IS 13703 part 2 ,415VAC, 50Hz.(Make:-L & T, Type Code-SF90159)

6

-

-

... More
1.5 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand(No of Wire dia/Wire Dia-30/0.25) 1.1 KV grade as per IS:694.(Make-Polycab/Other approved Make)(For Control Circuit)

200

-

-

... More
10 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand(No of Wire dia/Wire Dia-80/0.40) 1.1 KV grade as per IS:694.(Make-Polycab/Other Approved Make)(For Power Circuit)

50

-

-

... More
25 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand(No of Wire dia/Wire Dia-196/0.40) 1.1 KV grade as per IS:694.(Make-Polycab/Other Approved Make)(For Power Circuit)

25

-

-

... More
95 Sqmm PVC insulated(Un-sheathed) FR-LSH Cu wire single core multi strand(No of Wire dia/Wire Dia-475/0.50) 1.1 KV grade as per IS:694.(Make-Polycab/Other Approved Make)(For Power Circuit)

6

-

-

... More
95-13 (mm²-E) copper tube terminal heavy duty.(Make-Dowells, Cat No-CUS-561)

30

-

-

... More
10-8(mm²-E) copper tube terminal heavy duty.(Make-Dowells, Cat No-CUS-547)

60

-

-

... More
25-10(mm²-E) copper tube terminal heavy duty.(Make-Dowells, Cat No-CUS-552)

30

-

-

... More
35-10(mm²-E) copper tube terminal heavy duty.(Make-Dowells, Cat No-CUS-554)

30

-

-

... More
1.5-6(mm²-E) copper tube terminal heavy duty.(Make-Dowells, Cat No-CUS-539)

60

-

-

... More
25 Sqmm Single Compression gland.(Make:-Dowells, Product Code-DGP10006)

6

-

-

... More
35 Sqmm Single Compression gland.(Make:-Dowells, Product Code:-DGP10009)

6

-

-

... More
PVC Separation Board, Cable tie, MCb chanel etc.

1

-

-

... More
At first remove the damaged power contactor, Star-Delta timer etc from the existing panel after disconnection of all power line.Then fixing the above supplied materials at same place, then making power & control circuit wiring through out the panel work must be done by Experienced electrician and wholly satisfaction of EIC.

1

-

-

... More
Atfirst scrabbing the whole panel sheet by emery paper, then blown out all dust, dirt etc from the panel then painted with CRCA paint as per fully satisfaction of EIC.

1

-

-

... More
Add GST @ 18%

1

-

-

... More
Add CESS @ 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.