Public Health Engineering Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Health Engineering Department - PHED Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date9 Sep 2024
Closing Date17 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Line regulation:- Out put voltage should remain well with ±1% of set voltage (From Minimum to Maximum i.e. either 400V. or 415V. supply variation).

1

-

-

... More
Load regulation : Output voltage should remain neutral well within ±1% of set voltage be ( From no load to full load ) i.e. either 400V. or 415V.

1

-

-

... More
Correction speed:- Better than 35 Volt / Second.

1

-

-

... More
Efficiency:- Better than 95% on full load.

1

-

-

... More
Cut off limit (minimum &maximum ) by limit switch with Audio & Visual.

1

-

-

... More
Metering Indication:- By Selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an Ammeter with selector switch should be available.

1

-

-

... More
Lamp Indication :- For Input & Output should be provided. ( 3 lamps per side ).

1

-

-

... More
MCCB Protection: For Input side.

1

-

-

... More
Load protection : MCCB on each output phase should be available

1

-

-

... More
Output over shoot:- Beyond 210V to . 255V /phase in case of “ MANUAL MODE” & voltage protection :AUTO MODE” operation.

1

-

-

... More
VISUAL Indication for under voltage & over voltage of output.

1

-

-

... More
Manual Mode:- Up & Down correction with O / P voltage over shoot protection. Beyond 210 V-255 V. per phase.

1

-

-

... More
Nature of cooling:- Oil cooled system.

1

-

-

... More
Electric current over load protection .

1

-

-

... More
Circuit for delay output

1

-

-

... More
Input high voltage cut-off above 500 V.

1

-

-

... More
Mode of Operation:- AUTO/MANUAL with a provision to restore the normal working of the unit “STANDBY OPERATION” should be available in case of any Electronic failure in auto mode.

1

-

-

... More
Auto Mode:- Normal * Standby.( Manufacturing test certificate should be Provided at the time of delivery).

1

-

-

... More
Supply and Delivery of foollowing materials at site

1

-

-

... More
100 Amp. 4 pole on load change over switch (Make:Approve make of P.H.E. Dte.)

1

-

-

... More
100 Amp. Re-wireable type TPN main switch (Make: Approve make of P.H.E. Dte.)

1

-

-

... More
100 Amp. 4 way Copper busbar chamber box by 16 SWG sheet steel enclosure including porcelain Chair etc. with painting complete as per direction of the EIC. (Approved make)

1

-

-

... More
25 sqmm. 3 ½ core PVC insulated 1.1KV, AI., Ar. cable(Make: Approve make of P.H.E. Dte.)

20

-

-

... More
Making brick built foundation with supplying of all required materials suitable for the above Voltage stabilizer by (4:1) cement mortar including holding down foundation bolts(If required) and plaster with neat cement finish as per direction of E.I.C.

1

-

-

... More
Fitting, Fixing and connection of above supplied changeover switch, bus-bar and Main Switch as in item no 2/2.01 to 2/2.03 on the wall by supplying all necessary materials to complete the job as per direction of E.I.C

1

-

-

... More
Installation of the above voltage stabilizer of item no. 1 on the foundation including all connection complete as per direction of E.I.C

1

-

-

... More
Drawing and connection of cable on wall as in item no. 2/2.04 and all connection complete with all equipment as per requirement and as per direction

20

-

-

... More
Making joints of the cable by supplying compression type gland thimple, socket etc.as per requirement and as per direction of EIC.

8

-

-

... More
Earthing with 50 mm dia. G.I. pipe, 3.65 mm thick & 3mtrs long (2 sets) and conn. by 25x 6 mm G.I. strip ( for reqd length) upto the earth bus-clamp with the equipments on wall/floor with staplesburied inside as reqd. at site and with 25 mm x 6mm GI flat strip to earth electrode pipe,fastening with 13mmx80mm G.I bolts,nuts,washers, including all f & f of materials & filling & restoring the surface by ramming &making suitable earthpit with brick structure & MS lid on top as per direction.

1

-

-

... More
Add GST @ 18%

1

-

-

... More
Add LWC @ 1%

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.