Public Health Engineering Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Public Health Engineering Department - PHED Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date17 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 90,00,000
Costs
EMD
₹ 1,80,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Wbphed/ee/bmd/niet-16 Of 2024-2025/5
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PHED_796322_5Tender No
WBPHED/EE/BMD/NIeT-16 OF 2024-2025Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://www.wbphed.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
10
-
-
... More
Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
15
-
-
... More
Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and consolidating same by thorough saturation with water ramming complete including cost of supply of sand.
5
-
-
... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
5
-
-
... More
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth
2.6
-
-
... More
(b) In superstructure, ground floor
0.6
-
-
... More
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes. i) Pakur variety
1.2
-
-
... More
Plaster ( to wall, floor , ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and racking out joints or roughening of concrete surface including throating nosing and drip course where necessary (Ground floor).[Excluding cost of chipping over concrete surface] a) With 1:6 Cement mortar ( 25mm thick)
30
-
-
... More
Neat cement punning about 1.5mm thick in wall. dedo, window sill floor etc
Note- Cement0.152 Cum per 100sqm
15
-
-
... More
Moveable Galvanized plain sheet Pit cover M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
40
-
-
... More
Galvanised plain sheet works (excluding supporting framework) fitted and fixed with 6 mm. dia J or L hook-bolts and nuts, sheet-bolts, limpet and bitumen washers and putty with 150 mm. end lap & 50 mm minimum side lap complete.
(a) In roof: with 0.63 mm. sheets.
5
-
-
... More
Supply delivery and storage at site of caustic Soda Flskes as per IS-252-2013 {@300 kg,/site}
300
-
-
... More
Supply, delivery at site of 1 no 100 Amp T.P.N. Main switch with re-wireable Fuse system with iron frame and fixing the same on wall by supplying necessary fixing materials for receiving 3 phase power connecticn frorn purnn house along with supplying and drawing of 4 core, 25 sq nrm Al. Armoured cabie from 100 amp main Switch to control panel {approx 15 mtr.) as required.
1
-
-
... More
Excavation of soil for installation of Earth Electrode and filling & ramming for soft soil
2
-
-
... More
Earthing with 50 mm dia GI pipe (ISI-Medium GI Pipe)x 3.04 Mtr. long and 1x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 13 mrn dia x 80 mm long galvanized bolt, double nuts, double washer including S & F 15 mm dia Gl pipe (ISI Medium) protection (1 Mts, long) to be filled wlth bitumin partly under the ground level and partly above ground level driven an avarage depth of 3.65 Mts below the ground
2
-
-
... More
Extra for proviiding masonery enclosure on the top of the earth eiectrode of overall size 86.3 crn x 86.36 cm x 46 cm deep{below Ground level} complete with cernented brick work{1.:6} of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover { size 36.56 cm x 35.5 cm with locking arran6ement, Gl reducer including drilling of 46 nos 12 mm dia holes on the GI pipe.
2
-
-
... More
Extra for treatment of soil by using salt & charcoal or coke for pipe electrode
2
-
-
... More
Supplying & fixing earth busbar of galvanized (Hot Dip} MS ftat 50 mm x 6 mm on wall having clearance of 6 rnrn frorn wall including providing drilled holes on the birsbar (ornplete with 6l bolts, nuts, washers, spacing insulators etc. as required.
1
-
-
... More
Connecting the equipments ts earth busbar including S & F GI (Hot Dlp) wire of Solid Gl wire {8 SWG) on wall/floor withstaples buried inside wall,/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and rnending good demages.
20
-
-
... More
Yard light At CWR and OHR Site.
-
-
-
... More
Supply and delivery and storage of the following at site
-
-
-
... More
Supply of swaged / stepped type steel tubular pole of 9m long (410‐SP‐26) conformed to IS : 2713-1980. The length of bottom section shall be 5.0 mtr, middle section shall be 2.0 mtr & top of 2.0 mtr. The bottom section of the pole shall be 114.3 x 4.50mm dia, middle section of the pole shall be 88.9 x 4.05 mm dia & the top portion shall be 76.1 x 3.25 dia, 1.5 mtr. long MS bracket made out of 40 mm dia MS pipe shall be fixed on top of the pole for fixing light fiottings. The MS mounting bracket shall be fixed on top of the pole weight approx 92 Kg Make- Approved vendor list of PHE Dte.
N.B- Certificate of Pole from manufacturer should be
produce at the time of delivery
a) Single Arm
(ohr-6,cwr-10)
16
-
-
... More
Supply delivery & fitting fixing of Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.
M.No-BRP409 LED115 CW SLC FG PSU GR V2 of
Philips make or equivalent model)
22
-
-
... More
6 sqmm 4 core 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,
500
-
-
... More
Excavation of soil for installation of Earth Electrode and filling & ramming.1,500 mm. and upto 3,000 mm. but not
requiring shoring.
(a) For Soft Soil
20
-
-
... More
Erection of Single tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
16
-
-
... More
Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole
22
-
-
... More
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 250 x 250 x 100mm
22
-
-
... More
Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated FRLS 1.1 kv grade copper flexible cable
22
-
-
... More
Supply and fitting fixing of 20mm dia GI pipe Medium
quality (TATA) from muffing to Joint box
20
-
-
... More
Laying through Underground Trech;
Laying of one No. cable upto 35 sqmm in underground
trench 460 mm wide x 760 mm average depth, with brick
protection on the top of the cable with 8 (eight) Nos.
bricks per metre, including filling the space between the
brick & cable and also the trench with shifted soil,
leveling up and restoring surface duly rammed
450
-
-
... More
Laying on Wall / surface with Saddles / Clamps; Laying of cable upto 2 core 25 sqmm on wall/surface
incl. S & F M S saddles with earthing attachment in 10
SWG GI (Hot Dip) Wire, making holes etc. as necy.
mending good damages and painting
50
-
-
... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as
below :
For 4 core 6 sqmm cable
22
-
-
... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
i) 4 core 6 sqmm cable
22
-
-
... More
Painting of Steel Tubular Pole of lengths and no. of
coats of paint,as given below with ready mixed
paint/primer of approved make, and brand incl.
preparation of surface by sand paper/emery paper,
cleaning etc. for receiving fresh coat of paint
Upto 9.0 mtr. long pole
-
-
-
... More
i) One coat of red lead/Zinc chromate priming
16
-
-
... More
ii) 1st coat of synthetic enamel paint over the primer
16
-
-
... More
ii) 2nd coat of synthetic enamel paint over the 1st coat
16
-
-
... More
Excavation of soil for installation of Earth Electrode and
filling & ramming. i) For Soft Soil
16
-
-
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level asbelow:
By ISI-Medium GI pipe
16
-
-
... More
a) Supplying and fixing 240/415V MCB Isolator on din rail of existing DBs and necessary connection.
i) 40Amp 4 pole
(Make-Havels/L&T/Legrand/Approved make)
4
-
-
... More
b) Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing
DBs and necessary connection
A) 16 A (SPN) Make-Havells
4
-
-
... More
PART-B for Internal Illumination
-
-
-
... More
Supply and fixing TPN main switch 32Amps 415 Volt TPN Sheet steel enclosed re-wireable fuse type Main Switche with side handle operated .
1
-
-
... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
A) 16 A (SP) Make-Havels
[2nos internal light & 2nos out door light]
4
-
-
... More
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
A) 40 A (DP)
Make-Havels/L&T/Legrand/Any Approved make
1
-
-
... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed
in wall after cutting the wall & mending good the
damages to original finish incl. Inter connection with
suitable size of copper wire and neutral link & provision
for earthing attachment
a) 2+4 way Make-Havells Enclosure
(DHDPSNODRW04)
2
-
-
... More
Distribution wiring in 1.1 KV single core stranded 'FR'
PVC insulated & unsheathed copper wire (Brand
approved by EIC) in 20mm size PVC rigid conduit 'FR'
(Precision /Zeolite make) incl. necy. fittings as required
i) 2 x 36/0.3(2.5sq mm) + 1x 22/0.3(1.5sq mm) ECC [10mtr for internal light & 10mtr for out door light]
20
-
-
... More
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core
stranded 'FR' PVC insulated & unsheathed copper wire
(Brand approved by EIC) in 20mm size PVC rigid
conduit 'FR' (Precision/Zeolite make), with 1x22/0.3 (1.5
sqmm) single core stranded 'FR' PVC insulated &
unsheathed copper wire for ECC, to light/fan/call bell
points with Piano Key type switch fixed on MS CRC
sheet metal (16 SWG) switch board cum JB on wall
complete with 2 no. suitable size “Ph & N” copper bar
incl. bakelite/Perspex (wall matching color) top cover 3
mm thick and incl. 175mmx100mmx65mm inspection box,
making earthing attachment, painting the MS box and
mending good the damages to original finish
Average Run-8 Mtr
5
-
-
... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision /Zeolite make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
i) On Board
2
-
-
... More
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
1
-
-
... More
Supply and fitting fixing on the wall 1 x 22 watt single commercial type surface mounted LED Base tube light
with complete set. Type -BN 021 LED40S- 6500 PSU GR (4 ft)
(for Philips make)
2
-
-
... More
Supply and fitting fixing on the wall 20 Watt capacity
LED Bulb Stellar Bright cacity 2000lm and 15K life hours
HSN Code: 85395000 for Philips make)
1
-
-
... More
Supply and fixing 9W LED lamp for toilet
2
-
-
... More
At River side CWR Site
-
-
-
... More
Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE 3star(minimum) rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category Bmotor) as per NIT
-
-
-
... More
a) Discharge-22 M3/Hour, Total head -29 Mtr
4
-
-
... More
Supply, delivery and storage at site 80 mm dia UPVC
Column pipe medium gauge both side 8 TPI threaded
and one side heavy type socket other site rubber cap
for threaded protector Standard (17kg/cm2).
-
-
-
... More
a) 1.5 Mtr. Long
12
-
-
... More
Supply, delivery and storage at site of following L.T cables
-
-
-
... More
16 Sq. mm 3 core, 1.1 KV grade, Al. Ar, XLPEA cable conforming to IS : 7098 (Part – I).
Make:Gloster/havells/Polycab
3000
-
-
... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
(a) Depth of excavation not exceeding 1,500 mm. size of the trenches (W-600mm, D-750mm L-200mtr)
92
-
-
... More
Laying of 10 sq mm Al, Ar cable in an underground trench in single tier formation (horizontal), the trench size : W-600 mm x 750 mm average depth, (ordinery without brick protection) laying 4nos cable and maintaining gap minimum 150mm gap in between two cable also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed as per direction of E.I.C
400
-
-
... More
Laying of Al Ar cable through with fixing & laying of Cable along the lenth of River Bed 80- 100mm dia GI delivery pipe line by the above supplyed M.S Clamp and G.I Wire as per direction of E.I.C
a) 16 Sqmm 3 Core Al, Ar Cable
2600
-
-
... More
Lowering of the above Submersible pump motor set into the river bed tube well with proper lifting arrengement and testing up to the satisfection of EIC
4
-
-
... More
Providing & Installation of Solar Photo Voltaic Panels (Mono/Poly Crystalline) as per MNRE and NIeT
Specification for size of solar plant with necessary PV
array mounted on independent steel structure of
suitable height & in a suitable direction to optimize
panel use and withstand the wind pressure up to 200
Km /hour including necessary 3 phase inverter, cable,
switch/circuit breaker/connector/junction box, earthing,
lightening arrester, installation & commissioning with 5
year CMC.
(a) The PV Modules should be mounted on hot dip
galvanized metallic structure of adequate strength and
as per drawing given in NIT
(b) Components & parts used in the solar system
including the metallic structure (MS) should confirm to
the BIS
(c) The rates of solar system includes compressive
maintenance contract(CMC) for 5 years
28
-
-
... More
Construction of RCC foundation for mounting Steel structure for installation of Solar panel Array including
earth excavation, sand filling, brick soling etc and as per
speecification given in NIT
23
-
-
... More
Add: 18% GST
1
-
-
... More
Add: 1% Cess
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%