Power System Operation Corporation Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Power System Operation Corporation Limited - POSOCO Tender
Eprocure
Opening Date20 Jun 2018
Closing Date4 Jul 2018
Tender Amount₹ 73,64,325
Costs
EMD
₹ 1,47,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_POSOC_351049_1Tender No
ERLDC/CnM/1163/CCTV/2018Tender Authority
Power System Operation Corporation Limited ViewPurchaser Address
-Website
http://https://posoco.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
32CH 1080P NVR, 2 HDDs, 1 x1000M Ports, 16 POE Ports, PAL, UL Listed
1
-
-
08 Port Layer 2 , 10/100 PoE Network Switch with 2 Nos. Gigabit SFP port
4
-
-
24 Port Layer 2 10/100/1000 Switch
1
-
-
55" LED Monitor suitable for 24/7 Operation
1
-
-
24 port loaded CAT 6 jack panel
5
-
-
4TB Surveillance HDD
8
-
-
B. Software details (if any) (Supply & Installation)
-
-
-
Central Video Management Software with 100 video Lic for Multiple NVR
1
-
-
C. Installation, cabling, fixing and other works / services (Supply & Installation)
-
-
-
4X4 PVC Junction Box
24
-
-
IP66 Weatherproof 6X6 Outdoor Junction Box
12
-
-
1 mtr. CAT 6 Patch Cord
24
-
-
3 mtr. CAT 6 Patch Cord
24
-
-
Single fate Face Plate with Surface Mount Box
24
-
-
CAT 6 Information Outlet I/O
24
-
-
Supply and Laying of CAT 6 Cable on actual basis.
1000
-
-
Supply and Laying of 3 Core Armored 1.5 Sq. mm. Power Cable on actual basis.
500
-
-
Supply and Laying of 25 mm PVC Conduit on actual basis.
1000
-
-
Supply, Installation, Testing and Commissioning of GI/HDPE as per required and other necessary accessories on actual basis.
100
-
-
D. Warranty & AMC (CCTV BASED SURVEILLANCE SYSTEM )
-
-
-
AMC for 1st Phase on completion of 1 year warranty period from date of TOC
2
-
-
AMC for 2nd Phase on completion of 1 year warranty period from date of TOC
2
-
-
ACCESS CONTROL SYSTEM INCLUDING ATTENDANCE SOFTWARE A. Hardware / equipment details (Supply & Installation)
-
-
-
IP based fingerprint access control Readers Featuring easy installation and user friendly operations. Integrated with fingerprint and proximity card, these series readers cover a full range of access control applications from a simple standalone door control to networked access systems.
5
-
-
RFID Reader
20
-
-
2 Door Controller
10
-
-
Electro Magnetic Locks, 600 lbs with green LED indictor for single door
24
-
-
Exit push button for releasing the door
16
-
-
Proximity Card
200
-
-
Integrated Time & Attendance System with access control
1
-
-
B. Software details (if any) (Supply & Installation)
-
-
-
Access control software with below feature Grant access and disarm system on valid card read
• Arm system on valid triple card read
• Valid/invalid cardholder verification
• Arm/disarm video verification
• Pop-up video on access or intrusion function
• Virtual alarm touchpad
– View intrusion control panel status
– VISTA® keypad control
• Live system control
– Arm/disarm intrusion system
– Multiple partition control
– Bypass/unbypass doors
– Live camera view, including PTZ
1
-
-
C. Installation, cabling, fixing and other works / services (Supply & Installation)
-
-
-
0.5 sqmm X 8C shielded flexible cable with all accessories on actual basis.
200
-
-
0.5 sqmm X 4C shielded flexible cable with all accessories on actual basis.
200
-
-
UTP CAT 6 cable with all accessories on actual basis.
2000
-
-
D. Warranty & AMC (ACCESS CONTROL SYSTEM INCLUDING ATTENDANCE SOFTWARE)
-
-
-
AMC for 1st Phase on completion of 1 year warranty period from date of TOC
2
-
-
AMC for 2nd Phase on completion of 1 year warranty period from date of TOC
2
-
-
FIRE DETECTION AND ALARM SYSTEM A. Hardware / equipment details (Supply & Installation)
-
-
-
Supply, installation, fixing, testing and commissioning of Intelligent Addressable Microprocessor based Multicriteria smoke-heat detector with Base with 360 degree viewing Alarm LEDs. The detector should be intelligent Automatic Floating Sensitivity adjustment type & can be programmed as heat mode. (UL Listed)
175
-
-
Supply, installation, fixing, testing and commissioning of Intelligent Addressable Rate of rise cum fixed heat activation heat detector at pantry with Base with 360 degree viewing Alarm LEDs. The detector should activate at 8.3deg per min increase of ambient temperature or at more than 57 deg ambient temperature .Code dial addressing. (UL Listed)
2
-
-
Supply, installation, testing and commissioning of VIEW Laser Detector with Advanced laser light source and patented optical design. Analog Addressable communications protocol with 0.02% - 2.00% sensitivity level. Dual bi-color (red/green) LEDs flash green when Normal and are steady red in Alarm. Dual LED design with 360° viewing angle Built-in magnetic test switch, or automatic test commanded from panel. (UL Listed )
7
-
-
Supply, installation, fixing, testing and commissioning of Intelligent Addressable Pull/Glass break type Manual call point with key arrangement to activate manual alarm. (UL Listed)
10
-
-
Supply, installation, fixing, testing and commissioning of Electronic Hooter cum strobe with min 82dB & 110 Cd output . Should have min 3 field changeable tap setting for Tone & flash. (UL Listed)
5
-
-
Supply, installation, fixing, testing and commissioning of Fault Isolator module to isolate shorted desired and loose circuits between two successive fault isolators with automatic resetting arrangement. (UL Listed)
9
-
-
Supply, installation, fixing, testing and commissioning of Addressable control relay module for the notification device. The module should monitor the cables for open & short circuit. (UL Listed)
3
-
-
Supply, installation, fixing, testing and commissioning of Addressable monitor/Control modules to monitor NO contacts at Sprinkler Flow Switch and Door Holders.(UL Listed)
4
-
-
Supply, installation, fixing, testing and commissioning of response indicator for Above false ceiling detectors
50
-
-
Supply, Installation, Testing & Commissioning of Microprocessor based 2 loop capacity Networkable Analogue Addressable type Fire Alarm Control panel. The FACP shall have minimum 640 characters Display with fully functional QWERTY Keypad. Each loop shall have a maximum loading of 125 detectors and 125 devices in one loop with 20% spare capacity. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and for 2 hours during an emergency conditions as required. FACP should be integrated with 8 channels Digital Voice Controller with capacity to communicate and transmit pre-recorded and paging messages through the 50 W Digital Audio Amplifiers distributed across various floors of the building on a Digital Audio Loop with 5 zone control function and other accessories required to complete the KC system. The System shall have capability to connect Fire Fighting Phone and Telephone Phone Jacks. FACP and Digital Voice Controller should be with Network Communication Module with true peer to peer Connectivity. (UL Listed)
1
-
-
Supply, Installation, Testing and Commissioning of 2 way communication Fire Fighter's Handset. Complete as required as per technical specification. Approvals UL)
1
-
-
Supply, installation, fixing, testing and commissioning of ceiling/wall mounted speakers with metal grill, MT & min 80db output at 2 watt tapping for emergency evacuation (UL Listed)
32
-
-
Supply and Installation of Server including PC base Graphical Repeater station for monitoring & controlling of all components of fire detection system. The Application shall allow the attachment of text (TXT) files sound (WAV) files image (BMP) files and video (AVI) files to each system or sensor icon allowing additional information to be provided to the system operator for responding to the off normal
1
-
-
Supply, installation, fixing, testing and commissioning of microprocessor based min 600 character repeater fire alarm panels, with outputs and complete with power supply unit. The Active Repeater panel should have min functionality eg acknowledge, signal silence & reset (UL Listed)
1
-
-
Supply and Laying of 2 Core 1.5 Sqmm ATC Multi-strand Copper FRLS Armored Cable on actual basis.
8000
-
-
NOVEC 1230 Inagent Fire Supression System at Server Room and UPS Room ( LXWXH- 16' X 16' X 12')
1
-
-
B. Warranty & AMC (FIRE DETECTION AND ALARM SYSTEM)
-
-
-
AMC for 1st Phase on completion of 1 year warranty period from date of TOC
2
-
-
AMC for 2nd Phase on completion of 1 year warranty period from date of TOC
2
-
-