West Bengal State Police Housing Corporation Limited Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal State Police Housing Corporation Limited Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Feb 2024
Closing Date11 Mar 2024
Tender Amount₹ 1,96,42,743 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of Excavation for additional depth beyond1500 mm and upto 3000 mm but not requiring Shoring

5

1146

229.3

... More
Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation.

40.01

3694

92.36

... More
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

123.5

104767

848.32

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand.

656

279108

425.47

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (B)With [Pakur Variety 1:3:6]

28.6

167427

5854.12

... More
6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur VarietyGROUND FLOOR Rate Analysis

95.7

727787

7604.88

... More
6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety,FIRST FLOOR Rate Analysis

62.9

485468

7718.1

... More
6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety,SECOND FLOOR Rate Analysis

44.45

348102

7831.32

... More
6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety Third FLOOR MUMTY

1.5

11916

7944.54

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work(Ground floor)

890.9

390730

438.58

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (From roof of ground floor to roof of first floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work First Floor

777.8

357811

460.03

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (From roof of first floor to roof of second floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Second Floor

299.78

144341

481.49

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (From roof of first floor to roof of second floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Third Floor/Mumpty

2.5

1257

502.94

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. I. SAIL/ TATA/RINL For work in foundation,basement and and upto roof of Ground Floor/upto 4m

14.34

1217846

84938.39

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. I. SAIL/ TATA/RINL FIRST FLOOR

9.8

837589

85450.87

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. I. SAIL/ TATA/RINL SECOND FLOOR

5.14

441679

85963.34

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. I. SAIL/ TATA/RINL 3 RD FLOOR (MUMPTY)

0.05

4323

86475.82

... More
Brick work with 1st class bricks in cement mortar (1:6) GL TO PL(a) In foundation and plinth

21.37

134806

6307.01

... More
Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,Ground Floor

81.52

535702

6571.59

... More
Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,FIRST FLOOR

89.18

597872

6703.88

... More
Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,SECOND FLOOR

59.61

407496

6836.16

... More
Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,3 RD FLOOR MUMTY

2.5

17421

6968.45

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)Ground Floor

253.67

218280

860.48

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)FIRST FLOOR

202.48

177121

874.78

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)SECOND FLOOR PWD SoR 2017 (vol I), 3rd corrigenda & addenda, Sl.-8 , P-3

161.31

143415

889.08

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4)THIRD FLOOR

2.5

2258

903.38

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).

81.75

18511

226.44

... More
Labour for Chipping of concrete surface before taking up Plastering work.

3432.4

85912

25.03

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar , b) 10 mm thick plaster. Ground Floor

518.42

79702

153.74

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar , b) 10 mm thick plaster. FIRST FLOOR

533.28

84530

158.51

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar , b) 10 mm thick plaster. SECOND FLOOR

93.75

15307

163.28

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar , b) 10 mm thick plaster. 3 RD FLOOR (MUMPTY)

2.5

420

168.04

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] , With 1:6 cement mortar a) 20mm thick plaster(Outside)Ground Floor

819.15

162060

197.84

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar a) 20mm thick plaster(Outside)FIRST FLOOR

426.95

86504

202.61

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar a) 20mm thick plaster(Outside)SECOND FLOOR

369.73

76671

207.37

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar a) 20mm thick plaster(Outside)3 RD FLOOR (MUMPTY)

15.04

3189

212.14

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar b) 15mm thick plaster(Inside)Ground Floor

1018.04

174716

171.62

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar b) 15mm thick plaster(Inside)FIRST FLOOR

1542.31

272047

176.39

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar b) 15mm thick plaster(Inside)SECOND FLOOR

208.4

37752

181.15

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar b) 15mm thick plaster(Inside)3 RD FLOOR (MUMPTY)

2.5

464

185.92

... More
Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqm

315.27

12774

40.52

... More
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)

184.98

24250

131.1

... More
White washing including cleaning and smoothening surface thoroughly.(b) Three coats (on new works only).. Inside

2457.25

58580

23.84

... More
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats):(b) Two coats (on new works only).External surface (Ground floor)

750

12690

16.92

... More
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats):(b) Two coats (on new works only).External surface (First floor)

353.48

6320

17.88

... More
Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats):(b) Two coats (on new works only).External surface (2nd floor)

61.8

1156

18.71

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (b) Two coats GROUND FLOOR

750

43800

58.4

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (b) Two coats FIRST FLOOR

353.48

20936

59.23

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. (b) Two coats SECOND FLOOR

58.8

3532

60.07

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. (All Floors) (b) Two Coats ii) Water based interior grade Acrylic Primer

2540

133807

52.68

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality

2540

187680

73.89

... More
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly , complete as per manufacturer's specification and as per direction of the EIC. (TWO COATS)Ground Floor (External surface)

1090.23

58599

53.75

... More
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly , complete as per manufacturer's specification and as per direction of the EIC. (TWO COATS)FIRST FLOOR (External surface) PWD BLDG(2017) It-8, P-196

720.08

39301

54.58

... More
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly , complete as per manufacturer's specification and as per direction of the EIC. (TWO COATS)SECOND FLOOR (External surface)

644.2

35701

55.42

... More
Applying exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly , complete as per manufacturer's specification and as per direction of the EIC. (TWO COATS)3 RD FLOOR (External surface)

200

11250

56.25

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality , as per manufacturee's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cosy of primer. a) Normal Acrylic Emulsion (Two Coats)Ground Floor (External surface)

1090.23

87054

79.85

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality , as per manufacturee's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cosy of primer. a) Normal Acrylic Emulsion (Two Coats)FIRST FLOOR (External surface) PWD BLDG(2017) It-17, P-197

720.08

58096

80.68

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality , as per manufacturee's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cosy of primer. a) Normal Acrylic Emulsion (Two Coats)SECOND FLOOR (External surface)

644.2

52515

81.52

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality , as per manufacturee's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cosy of primer. a) Normal Acrylic Emulsion (Two Coats)3 RD FLOOR (External surface)

200

16470

82.35

... More
b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

597.14

27044

45.29

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)

1

96

96.54

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

621.43

21476

34.56

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessaryb) iv) On Steel and other Metal Surface Two coat with any shade except white With super gloss (hi-gloss)

1

94

94.15

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick Ground Floor

290.77

110893

381.38

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick 1st floor

2.5

967

387.1

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thick 2nd floor

2.5

982

392.94

... More
18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m] GROUND FLOOR

295.02

356874

1209.68

... More
18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m], 1st floor

329.99

403895

1223.98

... More
18 mm. to 22 mm. thick, kota stone slab setting 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m], 2nd floor

25

30957

1238.28

... More
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]GROUND FLOOR

46.42

63789

1374.15

... More
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooks including pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]FIRST FLOOR

64.69

89816

1388.45

... More
Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]SECOND FLOOR

12.96

18176

1402.75

... More
Extra cost of labour for prefinished & premoulded nosing to trades of steps,railing,window sill etc of kota stone

67.58

18039

266.96

... More
Extra cost of labour for grinding kota stone floor in trades & riser of steps

40.04

9974

249.09

... More
Supplying, fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg)thick base of cement morter (1:2) laid with white cement slurry@ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (b) Area of each Granite slab 0.6 to 1.0 Square meter.

6.04

19910

3296.52

... More
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) a) ln Ground FIoor: (size not Iess than 600mmX 600 mm X 9.5 mm thick)

12

21237

1769.82

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative Ground Floor Floor tiles fixing

109.08

111543

1022.56

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative First Floor Floor tiles fixing

108.4

111494

1028.52

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative 2 nd Floor Floor tiles fixing

18.11

18734

1034.48

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative Ground Floor Wall tiles fixing

229.99

285333

1240.66

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative First Floor Wall tiles fixing

201.39

251056

1246.62

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Other than Coloured decorative Second Floor Wall tiles fixing

17.01

21307

1252.58

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal Malaysian.Ground Floor

1.15

113758

99179.21

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal Malaysian.First Floor

1.07

106078

99417.57

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal Malaysian.2 nd floor

0.25

25113

99655.93

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf) GROUND FLOOR

1

3169

3169

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf) FIRST FLOOR

1

3185

3185.68

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideeach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 35 mm thick shutters (single leaf) SECOND FLOOR

1

3202

3202.37

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (ii) 32 mm thick Ground Floor

32.87

108238

3292.94

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (ii) 32 mm thick First Floor

32.34

107033

3309.63

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. (ii) 32 mm thick 2 nd floor

9.98

33196

3326.31

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded with glass fibre reinforced plastic moulded skins and a special sandwich core , so as to impart monolitaheic composite structure as per approved technology of department of science and technology( DST) to satisfy IS:4020 door testing perfomance criteria (i) 66mm x 90mm All floors

229

135641

592.32

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2- track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film (Natural White)consider weight of 3-track Aluminium window @ 6.5 Kg per Sq.M. [Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M] PWD BLDG(2017) It-15, P-245

21.5

74616

3470.52

... More
Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, anodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2- track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film (Natural White)consider weight of 3-track Aluminium window @ 6.5 Kg per Sq.M. Louvered window (without glass) Rate analysis

19.5

100536

5155.73

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. -Without integrated grils -openable steel windows as per IS sizes with side hung shutters and horizontal glaging bars with/without fixed type ventilators Ground floor

34.89

91438

2620.77

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. -Without integrated grils -openable steel windows as per IS sizes with side hung shutters and horizontal glaging bars with/without fixed type ventilators First floor

53.73

142504

2652.23

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. -Without integrated grils -openable steel windows as per IS sizes with side hung shutters and horizontal glaging bars with/without fixed type ventilators Second Floor

2.16

5797

2684.05

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) ii) 4 mm thick

57.51

57436

998.73

... More
Extra for fixing glass panes in steel window

68.45

5465

79.85

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.vi) 6mm thick coloured / tinted / smoke glass.

1

787

787.78

... More
Two point nose aluminium handle including fitting and fixing.

124

8719

70.32

... More
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr. Ground Floor

28.94

334387

11555.69

... More
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr. First Floor

18.33

213899

11671.3

... More
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. mtr. 2 nd floor

4.3

50629

11787.97

... More
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 16 Kg./sq. mtr. Third Floor

1.08

12882

11905.84

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.

15.9

24710

1554.11

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. GROUND FLOOR

37.87

195417

5160.49

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. FIRST FLOOR

8

41696

5212.1

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. SECOND FLOOR

8

42113

5264.18

... More
M.S. gate of Jail type as per approved design made of strong M.S.framework, intermediate stiffeners and round/square bars orangles .M.S.sheet (notlessthan14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.

1

12025

12025.26

... More
Locking arrangement for Jail Type doors including supplying fitting and fixing in position complete as per approved design.

1

487

487.45

... More
Supplying,fitting and Fixing MS Clamps for Door and Window frame made of Flat bend Bar , end bifurcated with necessary screws etc by cement concrete (1:2:4) as per direction.(Cost of Concrete will be paid Seperately) 40mm x 6mm ,250 mm length

350

12096

34.56

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm

130

6662

51.25

... More
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (b) 250mm long.

82

15539

189.5

... More
(ii) Door stopper (Anodised aluminium)

79

6590

83.43

... More
ii) Godrej Hydraulic door closer fitted and fixed complete. (b) Medium type

12

23812

1984.35

... More
Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 10mm dia bolt.

187

22064

117.99

... More
(vi)steel peg stay 300 mm long including fitting and fixing.

120

5005

41.71

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod)(v) 125 mm grip x 12 mm dia rod.

148

18168

122.76

... More
Supplying fitting approved type ventilator in position after cutting holes in walls setting in cement mortar mending damages to wall and plaster and two coats of paint of approved brand sand shade. Payment of mending two damages of wall & plaster and painting to be made separately. R.C.C ventilator of 20 mm. thick Upto 0.10 sq.m. area

64

8237

128.71

... More
a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]

627.76

65839

104.88

... More
Supplying dividing strip fitted and fixed with cement mortar (1:3) in mosaic or patent stone floor, dado etc. complete as per direction of the Engineer-in-charge. (i) Glass - 3mm. Thick (b) 25 mm. wide strip

98.93

2121

21.45

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety (i) for roof treatment

61

364589

5976.88

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes Rate Analysis M15

3

19071

6357.06

... More
Cement concrete with graded jhama khoa (30mm size) excluding shuttering in ground floor in foundation. (a)1:3:6 proportion

-

5

5694.42

... More
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (a) Slab Thickness 20 to 25 mm

-

-

766.33

... More
B. SANITARY & PLUMBING Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) (a) For Exposed Work PVC Pipes (Supreem made) 40 mm (Main Riser)

401.71

139799

348.01

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) (a) For Exposed Work PVC Pipes Supreem made32mm(Roof ring) PWD SoR 2017 (vol II) S&P , It-19(I) (a),P-12

1

281

281.26

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) (a) For Exposed Work PVC Pipes Supreem made20 mm(Internal) PWD SoR 2017 (vol II) S&P , It-19(I) (a),P-12

1

153

153.74

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) (a) For Exposed Work PVC Pipes (Supreem made) 25 mm(Vertical) PWD SoR 2017 (vol II) S&P , It-19(I) (a),P-12

436.15

92005

210.95

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting willbe made seperately) (a) For Concealed work 15 mm PWD SoR 2017 (vol II) S&P , It-19(I) (b),P-13

114.13

18635

163.28

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40mm PWD SoR 2017 (vol II) S&P , It-4(v),P-5

23

45119

1961.7

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).32 mm PWD SoR 2017 (vol II) S&P , It-4(vi),P-5

1

1499

1499.28

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).25 mm PWD SoR 2017 (vol II) S&P , It-4(vii),P-5

36

39129

1086.92

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).20 mm PWD SoR 2017 (vol II) S&P , It-4(viii),P-5

1

783

783.01

... More
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Hindware/Parryware/Cera, made (a) With 'P' trap(with vent) PWD SoR 2017 (vol II) S&P , It-3(a),P-79

25

92483

3699.35

... More
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(b) Anglo Indian (ii) Plastic (hallow type) white PWD SoR 2017 (vol II) S&P , It-10(b)(ii),P-81

25

14450

578.02

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). (i) 580 mm X 440 mm PWD SoR 2017 (vol II) S&P , It-4(i),P-79

8

15378

1922.37

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White PWD SoR 2017 (vol II) S&P , It- 2,P-36

33

39919

1209.68

... More
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. ii) 450 mm long PWD S&P (2017) P-9(ii), I-43

60

5863

97.73

... More
Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long PWD S&P (2017) P-10(iv), I-43

34

3687

108.45

... More
Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.ii) 550 mm X 400 mm size PWD S&P (2017) P- 2(ii), I-41

28

73681

2631.49

... More
Supplying, fitting and fixing pedestal of approved make for wash basin (white) PWD S&P (2017), It-03 of pg 41

1

1784

1784.12

... More
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm PWD S&P (2017) P- 6(a)(i), I-42

2

7830

3915.06

... More
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass 25 mm dia. and 600 mm long PWD S&P (2017) P- 22(a)(ii), I-82

40

20498

512.47

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm PWD S&P (2017) P- 19, I-82

28

20455

730.57

... More
Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand). PWD S&P (2017) P- 19(a)(i), I-82

34

22489

661.45

... More
Supplying ,fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD SoR 2017 (vol II), It. 7(c)(ii), Pg 6

1

642

642.38

... More
Supplying, fitting and fixing bib cock or stop cock.(c) (i) Chromium plated Bib Cock (angular shape with wall flange)(Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand). PWD SoR 2017 (vol II), It. 7, Pg 6

26

26679

1026.14

... More
Supplying, fitting and fixing bib cock or stop cock. (b) (ii) Chromium plated Concealed Stop Cock (Equivalent to Code No.514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD S&P (2017) P-6, I-7

26

20885

803.27

... More
Supplying, fitting and fixing bib cock or stop cock.(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). PWD SoR 2017 (vol II), It. 7(d)(i), Pg 6

68

66049

971.32

... More
(f) Hand Shower (Health Faucet) with 1mtr Flexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). PWD SoR 2017 (vol II), It. 3(f), Pg 4

26

38764

1490.94

... More
Supplying, fitting and fixing shower of approved brand and make.(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model -Tropical / Sumthing Special of ESSCO or similar brand). PWD SoR 2017 (vol II), It. 3(a)(i), Pg 3

22

11851

538.69

... More
Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD SoR 2017 (vol II), It. 3(a)(iii), Pg 4

22

8101

368.27

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. (A) UPVC Pipes: 110 mm. Dia PWD SoR 2017 (vol I), It. 21(A)(ii), Pg 213

150

44871

299.14

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia. PWD SoR 2017 (vol I), It. -21 ,Pg 212`

53

10864

204.99

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia. PWD SoR 2017 (vol I), It. -21 ,Pg 212`

60

11441

190.69

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Mtr. Lengthc) 110 mm PWD S&P (2017) P- 23(A)(i)(b), I-68

410.15

142736

348.01

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Door Tee (110 mm) PWD S&P (2017) P- 23(B)(iii)(b), I-70

121

28120

232.4

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 87.5 dig.(110 MM) PWD S&P (2017) P- 23(B)(x)(b), I-71

121

17305

143.02

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings (iii) Door Bend (T.S.) 110 mm PWD S&P (2017) P- 23(B)(xi)(b), I-71

117

20497

175.19

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iv) Vent Cowl 110 mm PWD S&P (2017) P- 23(B)(xv)(b), I-71

29

1140

39.33

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsDoor Y (LH) & (RH).(110 MM) PWD S&P (2017) P- 23(B)(vi)(b), I-70

13

4276

328.94

... More
Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPipe Clip 110 mm PWD S&P (2017) P- 23(B)(xvi)(b), I-71

180

4505

25.03

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xxix) Passover (b) 110 mm PWD SoR 2017 (vol II), It. -23(B)(xxix)(b), Pg 72

8

3880

485.06

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xiii) Cross Tee (b) 110 mm PWD SoR 2017 (vol II), It. -23, Pg 71

7

1551

221.67

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Plain Tee (b) 110 mm PWD SoR 2017 (vol II), It. -23, Pg 70

12

1215

101.3

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 ix) Bend 45º (b) 110 mm PWD SoR 2017 (vol II), It. -23, Pg 71

18

1909

106.07

... More
Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(A) Above ground(i) 110 mm PWD S&P (2017) P- 24(A)(ii)), pg-74

560.15

38050

67.93

... More
Labour for fitting and fixing U.P.V.C pipes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 mtr. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(B) Under ground(i) 110 mm PWD S&P (2017) P- 24(B)(ii)), pg-74

1

100

100.11

... More
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.i) 635 mm X 395 mm X 420 mm PWD S&P (2017) P- 6(i), I-80

19

64966

3419.27

... More
Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect. PWD SoR 2017 (vol II), It. -14, Pg 81

12

16189

1349.12

... More
Supplying, fitting and fixing C.I. round grating.(ii) 150 mm PWD SoR 2017 (vol II), It. -18(ii), Pg 67

66

6685

101.3

... More
Supplying, fitting and fixing C.I. square jalli.(ii) 150 mm PWD SoR 2017 (vol II), It. -19(ii), Pg 67

58

7050

121.56

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity PWD SoR 2017 (vol II), It. -6(d), Pg 37

2

24870

12435.24

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(d)1500 litre capacity PWD SoR 2017 (vol II), It. -6(c), Pg 37

4

37374

9343.71

... More
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 3rd story from G.L. PWD SoR 2017 (vol II), It. -10(i), Pg 37

1

216

216.91

... More
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 2nd story from G.L. PWD SoR 2017 (vol II), It. -10(i), Pg 37

5

828

165.66

... More
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. (a) Upto 2nd story from G.L. PWD SoR 2017 (vol II), It. -10(i), Pg 37

1

269

269.35

... More
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. (a) At 4th story from G.L. PWD SoR 2017 (vol II), It. -10, Pg 37

2

881

440.97

... More
Supplying fitting fixing PTMT smart shelf of approved make of size 300 mm PWD SoR 2017 (vol II), It. -21, Pg 82

38

10099

265.77

... More
Suppling fitting fixing soap holder a)PTMT (Prayag or Equivelent) PWD SoR 2017 (vol II), It. -18(a), Pg 82

45

7240

160.89

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. (2nd CORRIGENDA & ADDENDA page-1 Date: 04.06.2018) i) With Pakur variety.(SAIL/TATA/RINL) PWD SoR 2017 (vol II), 2nd Corri Sl-1,P-1

13

112404

8646.51

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 users (2nd CORRIGENDA & ADDENDA page-11 Date: 04.06.2018) PWD SoR 2017 (vol II), 2nd Corri Sl-3,P-11

1

108420

108420.43

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and filling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be followed as per IS:2470,Part- I.Payment will be made separately on the basis of actual height based on relevant I.S.Code. (i) For 10 users A) With Pakur variety. (SAIL/TATA/RINL) PWD SoR 2017 (vol II), 2nd corrigenda & addenda It. -3, Pg 7

1

42997

42997.76

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia. (2nd CORRIGENDA & ADDENDA page-13 Date: 04.06.2018) For-SAIL/TATA/RINL PWD SoR 2017 (vol II), 2nd corrigenda & addenda It. -4, Pg 14

3

59162

19720.71

... More
(a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where ecessary.

200

6602

33.01

... More
Supplying fitting and fixing 600 mm (+/- 30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc. (The rate is exclusive of the cost of posts)

40

19450

486.25

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof. I) For structural members of specified sections weighing less than 22.5 Kg./m

0.15

12979

86528.26

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m

-

86

86943

... More
Galvanised plain sheet works (excluding supporting framework) fitted and fixed with 6 mm. dia J or L hook-bolts and nuts, sheet-bolts, limpet and bitumen washers and putty with 150 mm. end lap & 50 mm. minimum side lap complete.(b) In roof: with 0.63 mm. sheets.

-

-

542.27

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one metre width on each side and preparing the bed by necessary cutting or filling, including cost of all materials andhire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Worksof MoRT&H (5th Revision). (iii) Grading-II Aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) Manual Means Rate Analysis

26

93211

3585.05

... More
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code,laid in pattern as directed in pavement, footpath, driveway(paver block only), etc including necessary underlay complete in all respect with all labour and material.[Border concrete if necessary to be paid separately].Note: Sub-grade CBR should not be less than 5.c) (c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone, commercial & office complex, tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering complete, including cost of sand but excluding cost of base, sub-base course & subgrade preparation) complete as per direction of Engineer-in-Charge. Color Decorative PWD SoR 2017 (vol I), 3rd Corri Sl-27(c)(ii), Pg 38

115.5

204965

1774.59

... More
Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Rate Analysis

78

212117

2719.45

... More
80 mm thick interlocking designer concrete paver block M-40 grade for medium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering complete, including cost of sand but excluding cost of base, subbase course & subgrade preparation) complete as per direction of Engineer-in-Charge.[Note: Subgrade CBR shouldnot be less than 5] Color Decorative PWD SoR 2017 (vol I), 3rd Corri Sl-2, Pg 80

156

323316

2072.54

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (The rate is inclusive of cost of all materials, labour, hire and usage charges of machinery and all incidental charges in this connection.) A) Using Concrete Mixer PWD SoR 2018 (Road), It- 8.01 (A),p-269

26

8676

333.7

... More
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (e) For depth upto 150 metre for 80 mm dia. tube well with top enlargement of 150 mm dia. (i) 80 mm dia. boring etc. PWD SoR 2017 (vol II), It. -1(e)(i), Pg 49

108

36941

342.05

... More
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(e) For depth upto 150 metre for 80 mm dia. tube well with top enlargement of 150 mm dia.(ii) 150 dia. boring etc. for top enlargement PWD SoR 2017 (vol II), It. -1(e)(ii), Pg 49

42

34287

816.38

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239(Part - I).b) 150 mm dia PVC Pipes PWD SoR 2017 (vol II), It. -19(III)(A), Pg 14

44

74463

1692.36

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). a) 80 mm dia PVC Pipes PWD SoR 2017 (vol II), It. -19(III)(A), Pg 14

70

48220

688.86

... More
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (iii) 80 mm dia. PWD SoR 2017 (vol II), It. -6(iii), Pg 52

36

21109

586.37

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (k) (i) 150 mm dia. medium quality PWD SoR 2017 (vol II), It. -1, Pg 2

1.2

2206

1838.95

... More
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. PWD S&P 2017 (vol II), It. -20, Pg 55

1

8983

8983.79

... More
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete.Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water. PWD S&P 2017 (vol II), It. -24, Pg 55

5

12090

2418.16

... More
Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. PWD S&P 2017 (vol II), It. -25, Pg 55

3

1490

496.98

... More
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. PWD SoR 2017 (vol II), It. -29, Pg 56

1

9828

9828.77

... More
Collecting sample of water for bacteriological test & chemical test from any depth at any time during execution of work including hire & labour charge for tools & plants & sterilising the equipments, paying all charges & fees, testing etc. complete in all respect as per direction. PWD SoR 2017 (vol II), It. -23, Pg 55

1

1467

1467.11

... More
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scaffolding, labour etc. all complete. PWD SoR 2017 (vol II), It. -22, Pg 55

1

1091

1091.69

... More
Supplying ,fitting, fixing steel cutter piece upto 450 mm. long with socket(iii) 75 mm dia PWD SoR 2017 (vol II), It. -9(iii), Pg 53

1

480

480.3

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). f) Reducing Scoket (150 x 80 ) PWD SoR 2017 (vol II), It. -19(III), Pg 18

1

542

542.27

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). j) Nipple (300 mm long ) 150 mm dia PWD SoR 2017 (vol II), It. -19(III)(iii), Pg 16

1

536

536.31

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). j) Nipple (150 mm long ) 50 mm dia PWD SoR 2017 (vol II), It. -19(III)(iii), Pg 16

1

61

61.97

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (J) Threaded End Cap Dia 80 mm PWD SoR 2017 (vol II), It. -19(III)(H), Pg 17

1

101

101.3

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (K) End Plug Dia 150 mm PWD SoR 2017 (vol II), It. -19(III)(K), Pg 18

1

1080

1080.96

... More
Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work a) 50 mm dia medium quality (For Vertical column pipe & upto Header) (A)-(II) G.I. pipe & fittings item no -1(f) (ii) PWD SoR 2017 (vol II), It. -1(A)(f)(ii), Pg 2

54

34752

643.57

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes (Dia) 50 mm PWD SoR 2017 (vol II), It. -19(II), Pg 13

170

81651

480.3

... More
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (vi) 50 mm PWD SoR 2017 (vol II), It. -12(vi), Pg 53

1

2625

2625.54

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (iv) 50 mm dia PWD SoR 2017 (vol II), It. -4, Pg 5

3

8445

2815.03

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (B) Socket Dia 50 mm PWD SoR 2017 (vol II), It. -4(iv), Pg 5

6

379

63.17

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). 50 mm dia PVC Union PWD SoR 2017 (vol II), It. -19(III)(I), Pg 17

6

1072

178.77

... More
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).50 mm dia PVC Flange PWD SoR 2017 (vol II), It. -19(III)(G), Pg 16

2

381

190.69

... More
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. PWD SoR 2017 (vol II), It. -27, Pg 56

1

2663

2663.67

... More
Providing 200 mm centre guide. i) With Clamp PWD SoR 2017 (vol II), It. -28(ii), Pg 56

1

152

152.55

... More
Electrical Schedule items Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) A. 4 bars 415 V, 200 A AL

1

3315

3315.59

... More
Supplying and fixing 415V, 63 A TPN SFU (LT/Havells/Siemens) with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.

2

9849

4924.52

... More
Supplying and fixing 40A DPMCB,10KA & C- charactaristic (All Legrand/L&T/ABB) WITH 2 WAY MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

3

4319

1439.69

... More
Supply & fixing 4 way double door horizontal TPN MCB DB with SS enclosure (Legrand/Seimens/ABB) concealed in wall after cutting the wall & mending good the damages to original finish with earthing attachment comprising with the following. a) 100 A Four Pole isolator -- -1 No. b) 32 A SPMCB. --- 12 Nos. (10KA & C characteristic )

2

14439

7219.92

... More
Supply & Fixing (2+12) way SPN MCBDB with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand/havells/ABB): a) 40A DP MCB isolator & necy. connection --- 1 no b) 6 to 16A SP MCB as required breaking capacity 10KA & C characteristic ---- 12 nos

2

10454

5227.23

... More
Supply & Fixing (2+8) way SPN MCBDB with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand/havells/ABB): a) 40A DP MCB isolator & necy. connection --- 1 no b) 6 to 16A SP MCB as required breaking capacity 10KA & C characteristic ---- 8 nos

4

15951

3987.76

... More
Supply & Fixing (2+6) way SPN MCBDB with IP-42/43 protection Concealed in wall & mending good the damages to original finish incl. Interconnection with suitable copper wire & nuetral link incl. earthing attachment comprising with the following (All Legrand/havells/ABB): a) 40A DP MCB isolator & necy. connection --- 1 no b) 6 to 16A SP MCB as required breaking capacity 10KA & C characteristic ---- 6 nos

2

5456

2728.03

... More
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

100

6793

67.93

... More
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

245

17519

71.51

... More
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed

250

48267

193.07

... More
Fixing only starters (for motor control) on angle iron frame on wall (UP TO 5 H P)

2

512

256.24

... More
Supply & laying 25mm dia medium gauge G.I. Pipe(ISI-Medium) for submursible cable protection

35

7216

206.18

... More
Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection a) 32 mm dia

10

2598

259.81

... More
Supply & laying medium gauge G.I.Pipe(ISI-Medium) for cable protection a) 40 mm dia

30

8795

293.18

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) 2 core 6sqmm

40

3241

81.04

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) 4 core 16/10 sqmm

26

4090

157.32

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) 4 core 25sqmm

6

1158

193.07

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : a) 2 core 6 sqmm

40

1525

38.14

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : a) 4 core 16 sqmm

26

2943

113.22

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : a) 4 core 25 sqmm

6

822

137.06

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a)2 x 84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC

175

28990

165.66

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a)2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC (AC)

170

19247

113.22

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (P/P,Com,Roof Light)

400

30988

77.47

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a)2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC

165

9439

57.21

... More
Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through alkathene pipe recessed in wall. a) 4x16+2x10 sq mm through 25 mm Alka.Pipe

10

10392

1039.25

... More
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire

285

21397

75.08

... More
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)

705

30244

42.9

... More
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. A) 6 SQMM

40

429

10.73

... More
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. A) 10 SQMM

8

104

13.11

... More
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. A) 16 SQMM

16

324

20.26

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Polycab/Havells/Kei/Finolex) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Crabtree/Havells/Legrand) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCa) a) Ave. run 8 mtr.

125

162830

1302.64

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories with 2 no. suitable size “Ph & N” copper bar embedded in wall to light/fan/ call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC a) (Ave. run 8 mtr.)

55

67318

1223.98

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Polycab/Havells/Kei/Finolex) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch(Cabtree/Crabtree/Havells) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC a) (on board)

45

13354

296.76

... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Polycab/Havells/Kei/Finolex) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch(Cabtree/Crabtree/Havells) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC b) (Ave run 4.5 mtr) separate 6A socket

25

27947

1117.91

... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type Power plug socket (Cabtree/Havells/Legrand) with 16A Modular type socket (Cabtree/Crabtree/Havells) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections

11

5978

543.46

... More
Supply & fixing of Modular type computer plug board of 12 module GI box with cover plate recessed in wall comprising of the following(All cabtree/Havells/Legrand): a) 6/16A socket & 16A switch ---1 set b) 6A socket & 6A switch --- 3 sets

6

10840

1806.77

... More
Supply & fixing of Modular type 16A control switch of 2 module GI box with cover plate recessed in wall comprising of the following (All cabtree/Havells/Legrand): a) 16A switch ---1 set

6

2080

346.81

... More
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.(For AC machine Power)

5

2103

420.71

... More
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.

2

307

153.74

... More
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener

100

11918

119.18

... More
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length

100

23717

237.17

... More
Supply & Fixing electronics step type, Moduler Socket type (2 module), Fan regulator (Cabtree/Legrand/havells)

50

23061

461.23

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box

30

6221

207.37

... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire

82

6450

78.66

... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust & louvre shutter after cutting hole on wall & mending good the damages of following diameter: 30 cm (12")

9

3528

392.1

... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust & louvre shutter after cutting hole on wall & mending good the damages of following diameter: 23 cm (9")

15

4415

294.37

... More
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12''

9

2070

230.02

... More
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 9''

15

2717

181.15

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. (ISI-M) long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:

8

13052

1631.57

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

8

8724

1090.5

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode

4

2531

632.85

... More
Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages a) 6 SWG

25

387

15.49

... More
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

34

3728

109.65

... More
Supply & fixing earth busbar of galvanised (Hot dip) MS flat 25mm x 6mm on wall having clearance of 6mm from wall Incl providing drilled holes onthe busbar complete with nuts, bolts & washers spacing insulator etc. as required

4

743

185.92

... More
Fixing only outdoor / street light type LED light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting

22

18930

860.48

... More
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.

4

2588

647.15

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint

22

12008

545.84

... More
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.

13

867

66.74

... More
Fixing only pendent light fitting complete with lamp, shade and 24/0.2 mm (1.5 sqmm) flexible copper wire incl. S&F pendent holder

1

57

57.21

... More
Fixing only lamp

44

262

5.96

... More
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board

2

412

206.18

... More
ELECTRICAL -NON-SCHEDULE ITEM Supply & delivery of 4' , 20 W single LED tube light fitting complete with all acessaries (Legero Batten cat no -DURA LIF 3118, Polycarbonate LED tube Cat no. Saber LRT-T8-020 20 W or equivalent as approved by EIC)

135

130623

967.58

... More
Supply & delivery of 4' , 2x 20 W Double LED tube light fitting complete with all acessaries (Legero Batten cat no -DURA LIF 3236, Polycarbonate LED tube Cat no. Saber LRT-T8-020 20 W or equivalent as approved by EIC)

59

86345

1463.49

... More
Supply & delivery of 2' , 12 W single LED tube light fitting complete with all acessaries (Legero cat no -RBJ 100 0012 or equivalent as approved by EIC)

6

2660

443.39

... More
Supply & delivery of 15W LED Bulk Head light fitting with LED lamp ip 65 protected (Legero-LBH 0015 or equivalent as approved by EIC )

13

17489

1345.32

... More
Supply & delivery of 9 W LED Lamp (Philps or equivalent) for batten light points

45

6772

150.49

... More
Supply,delivery and fixing on ceilling of 18 W LED surface mounted light fittings 1'X1' for false ceilling ( Make: (Legero cat no: Mento LES 4218 or equivalent )

40

92798

2319.97

... More
Supply & delivery of 72 W LED street light fitting (Make Legero, cat no -CLEO , LCL 0072 or equivalent )

13

70718

5439.86

... More
Supply & delivery of 90 W LED street light fitting (Make Legero, cat no -CLEO , LCL 0090 or equivalent )

7

54735

7819.42

... More
Supply & delivery of 45W LED post top light with IP 65 Protection(Make:-Legero cat no:Marshal LPM 4545 or equivalent )

2

14731

7365.93

... More
Supply & delivery of 100 W LED Flood light fitting (Make Legero, cat no -ASTRA-MW ,LAS 0100 or equivalent )

4

29011

7252.81

... More
Supply & delivery of 1200mm sweep Ceiling Fan with down rod (Orient-New Bridge/Usha-Striker with Safety Wire/ or equivalent ) complete with all acessaries.

76

160735

2114.94

... More
Supply & delivery of 1050 mm sweep Ceiling Fan with down rod (Orient-New Bridge/Usha-Striker with Safety Wire/ or equivalent ) complete with all acessaries.

4

8459

2114.94

... More
Supply of 300 mm (12") heavy duty exhaust fan 1420 RPM Exhaust Fan (make-EPC/Crompton/Orient or equivalent)

9

36969

4107.67

... More
Supply of 230 mm (9") heavy duty exhaust fan 1380 RPM Exhaust Fan (make-EPC/Crompton/Orient or equivalent)

15

36117

2407.84

... More
Supply & Fixing 240 V, 25 A, Modular type AC m/c starter (Eletron OLP - 3) 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire .(For AC m/c) .

7

15907

2272.5

... More
Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/KEI or equivalent) a) 2 x 6 sq mm

180

16180

89.89

... More
Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable (make Gloster/Polycab/Havells/KEI or equivalent) a) 4 x16 sq mm

240

38056

158.57

... More
Supply & delevery of 1.1 Kv grade XLPE Aluminium armoured cable(make Gloster/Polycab/Havells/KEI or equivalent) a) 4 x25 sq mm

250

54035

216.14

... More
AIR CONDITIONER Supply, delivery , installation, testing & commissioning with indoor and outdoor unit including bracket, connection cable, copper pipe etc. of 4 Star Non Inverter , Hi-Wall split type air-conditioning units with inbuilt 100% copper coil,combtible with R-32A refrigerant terbocool system Active carbon catehin with cordless remote.Make : Hitachi or equivalent as approved by EIC) a) 1.5 TR (4 Star rated Non Inverter unit)

2

91079

45539.89

... More
Supply,delivery & testing of 415V (3-Ph) 20 KVA Silent Deisel Generator Set ,AMF control pannel complete with all accessaries (Make Jackson/KIRLOSKER GREEN)

1

520838

520838.82

... More
Installation, testing & commissioning of the above D.G. set incl. making flatform for installation of above D.G.Set with Supply of full tank Diesel oil & required Mobil oil to satisfactory operation

1

14255

14255.65

... More
Supply and installation of 3 phase 415V, 3 Hp (2.2 Kw) submersible Pump Motor set suitable for 150mm bore well having overall head of (65 mtr to 35 mtr) & discharge RATE 5-14 m^3/hr.. The discharge outlet size will be 50mm.(Make KSB-IN606867/equivalent of KIRLOSKER/CROMPTON)

2

65142

32571.49

... More
Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable along with the column pipes into the tube well after socketing the column pipes step by step including arrangement of tripod, chain pully & tools & Tackles & providing suitable manpower to satisfactory operation.

2

4060

2030.1

... More
Supply of control panel suitable for 3 Phase 3 HP submersible pump motor set comprising of DOL starter, ammeter & voltmeter, indicator lamp to be fixed on wall incl making connection & necy earthing attachment.(Make of L&T or equivalent)

2

10148

5074.24

... More
Supply & delivery of 3 core 2.5 sqmm flat submersible cable (mescab or equivalent)

220

20220

91.91



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.