Panskura Banamali College Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Panskura Banamali College Tender

Works
Eprocure
Opening Date28 May 2018
Closing Date21 Jun 2018
Tender Amount₹ 1,57,73,744 
Notes
Download

Costs

Summary

Construction Of Three Storied Building Of Controller of Examination

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

503.17

174097

346

... More
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering and reinforcement. In ground floor and foundation) 6:3:1 proportion. a)Grround floor

35.38

153868

4349

... More
Nominal Mix (3:1.5:1) Cement Concrete with graded stone chips (20 mm size) excluding shuttering and reinforcement if any in ground floor a) Pakur verity. a)Ground floor

275.43

1556146

5649.88

... More
Nominal Mix (3:1.5:1) Cement Concrete with graded stone chips (20 mm size) excluding shuttering and reinforcement if any in ground floor a) Pakur verity. b) First Floor

68.82

395431

5745.88

... More
Nominal Mix (3:1.5:1) Cement Concrete with graded stone chips (20 mm size) excluding shuttering and reinforcement if any in ground floor a) Pakur verity. c) Second Floor

75.68

442113

5841.88

... More
Brick work with 1st class bricks in cement mortar (6:1). a)Grround floor a) In foundation & Plinth.

36.4

187751

5158

... More
Brick work with 1st class bricks in cement mortar (6:1). a)Grround floor b) Superstructure Ground Floor

26.93

144926

5381

... More
Brick work with 1st class bricks in cement mortar (6:1). b) First Floor

27.43

150651

5492

... More
Brick work with 1st class bricks in cement mortar (6:1). c) Seccnd Floor

45.16

253054

5603

... More
125 mm thick brick work with 1st class bricks in cement morter (4: 1) floor Grround floor

69.53

49160

707

... More
125 mm thick brick work with 1st class bricks in cement morter (4: 1) floor First Floor

140.43

100969

719

... More
125 mm thick brick work with 1st class bricks in cement morter (4: 1) floor Seccnd Floor

97.84

71521

731

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams, columns lintels curved or straight including fitting fixing and striking out after completion of works ( upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per direction & decision of the E.I.C. a)Grround floor

910.01

294843

324

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams, columns lintels curved or straight including fitting fixing and striking out after completion of works ( upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per direction & decision of the E.I.C. b) First Floor

609.79

208548

342

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs,beams, columns lintels curved or straight including fitting fixing and striking out after completion of works ( upto roof of ground floor). (a) 25 mm to 30 mm thick wooden shuttering as per direction & decision of the E.I.C. c) Second Floor

674.95

242982

360

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(a) for works in foundation, basement and upto roof of ground floor/upto 4m.i) Tor steel/Mild steel. a) Ground Floor

38.92

2240589

57569.08

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(a) for works in foundation, basement and upto roof of ground floor/upto 4m. i) Tor steel/Mild steel. b) First Floor

9.72

563983

57999.08

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(a) for works in foundation, basement and upto roof of ground floor/upto 4m. i) Tor steel/Mild steel. c) Seccnd Floor

10.69

624840

58429.08

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4)with stonechips laid in panels as directed with topping made with ordinary or white cement (asnecessary) and marble dust in proportion(2:1) including smoothfinishing and rounding off corners and application of cement cement slurry @1.75 kg./sq.m. all complete including and labours. In ground floor. 3 mm thick topping. 25 mm thick. a)Grround floor

91

24024

264

... More
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. Ground Floor

0.15

918

6123

... More
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. First Floor

0.15

918

6123

... More
M.S. round or square bar grating of windows etc. fitted and fixed in holes of window frame and with intermediate flat bar stiffener( with necessary holes for the grating bars and with the ends turned and fixed to timber frame with necessary screws) complete, as directed. Seccnd Floor

0.15

918

6123

... More
Wood work in door and window frame fitted and fixed complete including a protective coat of painting at the contact surface of the frame.Sal : Siliguri

1.18

102920

87220

... More
Wood work in door and window frame fitted and fixed complete including a protective coat of painting at the contact surface of the frame.Sal : Siliguri First Floor

1.5

131133

87422

... More
Wood work in door and window frame fitted and fixed complete including a protective coat of painting at the contact surface of the frame.Sal : Siliguri Second Floor

1.29

113032

87622

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete in all floors. 3 mm thick (weighing 7.4 kg / sq.m.)

1.08

515

477

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete in all floors. First Floor

1.08

515

477

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete in all floors. Second Floor

1.08

515

477

... More
Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc. a)Grround floor

91

3094

34

... More
Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc. b) First Floor

1

1

1

... More
Neat cement punning about 1.5 mm thick in wall, dado, window, sills, floor, drain etc. c) Second Floor

6

204

34

... More
M.S.or W.I.ornamental grill of approved design joints continuously welded with M.S., W.I. flat and bars for windows, railing etc fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing 10 kg./sq m and upto 16 kg./sq m.

4.93

35683

7238

... More
M.S.or W.I.ornamental grill of approved design joints continuously welded with M.S., W.I. flat and bars for windows, railing etc fitted and fixed with necessary screws and lugs in First Floor.

5.05

36917

7310.38

... More
M.S.or W.I.ornamental grill of approved design joints continuously welded with M.S., W.I. flat and bars for windows, railing etc fitted and fixed with necessary screws and lugs in Second Floor.

5.25

38759

7382.76

... More
Collapsible gate with 40 mm X 40 mm X 6 mm tee as top and bottom guide rail 20 mm X 10 mm X 2 mm vertical channel apart in fully streched position 20 mm X 5 mm M.S. flats as collapsible bracings properly rivetted and washered including 38 mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc in walls, floors etc and making good damages complete a)Ground floor

9.64

32795

3402

... More
Collapsible gate with 40 mm X 40 mm X 6 mm tee as top and bottom guide rail 20 mm X 10 mm X 2 mm vertical channel apart in fully streched position 20 mm X 5 mm M.S. flats as collapsible bracings properly rivetted and washered including 38 mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc in walls, floors etc and making good damages complete b) First Floor

3

10308

3436.02

... More
Collapsible gate with 40 mm X 40 mm X 6 mm tee as top and bottom guide rail 20 mm X 10 mm X 2 mm vertical channel apart in fully streched position 20 mm X 5 mm M.S. flats as collapsible bracings properly rivetted and washered including 38 mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc in walls, floors etc and making good damages complete c) Second Floor

5.04

17489

3470.04

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of cost of hinge and other fittings. In ground floor. 40 mm thick shutter with 19 mm thick panel. Gamari. a)Ground floor

35

97615

2789

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of cost of hinge and other fittings. In ground floor. 40 mm thick shutter with 19 mm thick panel. Gamari. b) First Floor

45.11

127106

2818

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of cost of hinge and other fittings. In ground floor. 40 mm thick shutter with 19 mm thick panel. Gamari. c) Second Floor

36.2

103061

2847

... More
Supplying, fitting & fixing in position approved P.V.C. door frame made from extruded P.V.C. multichamber hollow section having dimensions 60 mm x 50 mm / 60 mm x 53 mm and suitably reinforced, horizontal section will be joined with vertical section by steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40 mm x 20 mm x 18 guage will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner and steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. a)Ground floor

15.25

5871

385

... More
Supplying, fitting & fixing in position approved P.V.C. door frame made from extruded P.V.C. multichamber hollow section having dimensions 60 mm x 50 mm / 60 mm x 53 mm and suitably reinforced, horizontal section will be joined with vertical section by steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40 mm x 20 mm x 18 guage will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner and steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. b) First Floor

15.25

5871

385

... More
Supplying, fitting & fixing in position approved P.V.C. door frame made from extruded P.V.C. multichamber hollow section having dimensions 60 mm x 50 mm / 60 mm x 53 mm and suitably reinforced, horizontal section will be joined with vertical section by steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40 mm x 20 mm x 18 guage will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner and steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials taxes and all other incidental charges complete. c) Second Floor

15.25

5871

385

... More
Supplying, fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm wall thickness, the section will have two nos. built in beads, horizontal & vertical section shall be fixed by each other by self tapping screws and 2 nos. of M. S. tubular galvanised bracket of length 200mm x 80 mm and other 100 mm x 100 mm both 18 gauge in each corner of the shutter frame for placing hinges, polymer based multicavity hollow section of 2.5 mm wall thickness will be fitted in the middle with aluminium cleat and steel screws as lock rail, the section frame will then be fitted in by Polymer based panels of suitable size and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / dooring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of 100 mm Anodised aluminium hinges and cost of all materials a)Ground floor

5.57

13567

2438

... More
Supplying, fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm wall thickness, the section will have two nos. built in beads, horizontal & vertical section shall be fixed by each other by self tapping screws and 2 nos. of M. S. tubular galvanised bracket of length 200mm x 80 mm and other 100 mm x 100 mm both 18 gauge in each corner of the shutter frame for placing hinges, polymer based multicavity hollow section of 2.5 mm wall thickness will be fitted in the middle with aluminium cleat and steel screws as lock rail, the section frame will then be fitted in by Polymer based panels of suitable size and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / dooring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of 100 mm Anodised aluminium hinges and cost of all materials b) First Floor

5.57

13567

2438

... More
Supplying, fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm wall thickness, the section will have two nos. built in beads, horizontal & vertical section shall be fixed by each other by self tapping screws and 2 nos. of M. S. tubular galvanised bracket of length 200mm x 80 mm and other 100 mm x 100 mm both 18 gauge in each corner of the shutter frame for placing hinges, polymer based multicavity hollow section of 2.5 mm wall thickness will be fitted in the middle with aluminium cleat and steel screws as lock rail, the section frame will then be fitted in by Polymer based panels of suitable size and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / dooring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of 100 mm Anodised aluminium hinges and cost of all materials c) Second Floor

5.57

13567

2438

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 4: 1 cement mortar.10 mm thick plaster a)Ground floor

199.4

24726

124

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 4: 1 cement mortar.10 mm thick plaster b) First Floor

195.5

25024

128

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 4: 1 cement mortar.10 mm thick plaster c) Second Floor

205.7

27152

132

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.20 mm thick plaster a)Ground floor

280.78

43802

156

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.20 mm thick plaster b) First Floor

480.23

76837

160

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.20 mm thick plaster c) Second Floor

325.97

53459

164

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.15 mm thick plaster a)Ground floor

258.9

39612

153

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.15 mm thick plaster b) First Floor

189.3

29720

157

... More
Plaster (to wall, floor, ceiling etc) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including throating nosing and drip course where necessary. With 6: 1 cement mortar.15 mm thick plaster c) Second Floor

355

57155

161

... More
Priming one coat on timber, plastered or surface with synthetic enamel/ oil bound primer of approved quality including smoothening surfaces by sand papering etc. a)All floors

232.61

8839

38

... More
Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smoothening surfaces by sand papering etc. for All floors

50.59

1467

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc including using of approved putty etc on the surface. (a) On steel or other metal surface. With super gloss(hi-gloss) Two coats (with any shade except white). for All floors

50.59

3895

77

... More
With super gloss(hi-gloss) Two coats(with any shade except white). (b) On timber or plastered surface. for All floors

232.61

18144

78

... More
White washing including cleaning and smoothening surface throughly. A) All floors. i) Two Coats.a)Ground floor

803.2

16072

20.01

... More
M.S. clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4 : 2 : 1) fitted and fixed complete as per direction. (Cost of cement concrete will be paid separately). 40 mm X 6 mm dia rod above 170mmupto 250mm lenth

260

7540

29

... More
Anodised aluminium barrel/tower/ socket bolt (full covered) of approved quality manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws. 225 mm long X 10 mm dia bolt

26

2184

84

... More
Anodised aluminium decorative handle (hexagonal / fluted) of approved quality fitted and fixed complete. 150 mm plate X 10 mm dia rod x 12 mm.

26

2210

85

... More
Anodised aluminium Aldrop/Sliding bolts of approved quality manufactured from extruded section conforming to I.S.specification (I.S. 2681/66) fitted and fixed complete. 300 mm x 19mm dia. Bolt

26

7722

297

... More
Anodised aluminium floor door stopper

61

4270

70

... More
Supplying and laying Polythene Sheet (150 gm/sq.m.) over damp proof course or below flooring or roof terracing or in foundation trenches for All floors

3021

72504

24

... More
25 mm thick damp proof with cement concrete with stone chips (4 : 2 : 1) and admixture of water proofing compound as per manufacturer's specification over a coat of polymer based paint double chequered complete as directed (cost of water proofing compound and polymer based paint to be paid seperately.)

12.75

3277

257

... More
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in - Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (b) With Chawk Dungri ii) Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. (iii) Area of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur pink / Udaypur Green / Black Bhaslana (ii) Area of each Slab/tile exceeding 0.3 sq.m. but not exceeding 0.6 sq.m.

690.85

1157174

1675

... More
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone.

300

77400

258

... More
Extra cost of labour for marble stone floor in trade of steps

37.5

8475

226

... More
Supplying fitting and fixing 15 to 18 mm thick Marble slab/Tile in riser of step or skirting (upto 300 mm ht) over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] (b) With Chawk Doongri (ii) Area of each tile exceeding 0.3sq.m. but not ceeding 0.6 sq.m

165.21

327777

1984

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (D ) Wall With Polymerised Adhesive and Epoxy groutpointing including spacer- 2 mm ( When Tiles are laid over existing hard ready surface) (a) Area of each tile upto 0.09 Sq.m [using adhesive 3 mm thick] (i) Coloured decorative

142.76

163749

1147

... More
Washing and cleaning with oxalic acid powder using 33 gms./sq.m. (a) Marble floor/ marble dado

690.85

4815

6.97

... More
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]

40

92320

2308

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

19.2

147398

7677

... More
Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. i) 150 mm. (Godrej)

13

14053

1081

... More
(A) Supplying Aluminium casted body hydraulic door closer as per I.S.I.

13

17758

1366

... More
(D) Supplying Aluminium casted body Butt Hinge (KOBRA type).(Natural white)

200

11200

56

... More
b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) for all floors

2490.78

303875

122

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's pecification and as per direction of the EIC. for all floors b) i) Water based interior grade Acrylic Primer

1687.58

74591

44.2

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two Coats for all floors

803.2

36224

45.1

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) for all floors ii) Luxury Quality for all floors

1687.58

118131

70

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. c) Super Protective 100% Acrylic Emulsion. for all floors

803.2

78489

97.72

... More
12% GST on civil work of Rs. 1,24,93,075.58

1

1499169

1499169.07

... More
1% Cess on civil work of Rs. 1,24,93,075.58

1

124931

124930.75

... More
Internal Electrical Work of Rs 11,11,135.84(as per details mentioned in NIT)+12% GST & 1% Cess

1

1256916

1256916.86

... More
Sanitory and plumbing works of Rs 353,299.00 (as per details mentioned in NIT)+12% GST & 1% Cess

1

399651

399651.83



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.