Northeast Frontier Railway Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Northeast Frontier Railway - NFR Tender
Electrical Cables And Wires
Electrical and Electronics
Ireps
Opening Date12 Apr 2025
Closing Soon5 May 2025
Tender Amount₹ 3,03,05,435.68
AI Insights
Technical
Technical
Financial
Additional Eligibility
Bid Capacity
... View More
The formula for bid capacity, also referred to as average annual contractual turnover, is calculated as the average of total contractual payments in the previous three financial years. It can be represented as: Average Annual Contractual Turnover = (Total Contractual Payments in Year 1 + Total Contractual Payments in Year 2 + Total Contractual Payments in Year 3) / 3. Alternatively, the minimum average annual contractual turnover required for a tenderer is V/N or 'V' whichever is less, where V = Advertised value of the tender in crores of Rupees and N = Number of years prescribed for completion of work for which bids have been invited.
Technical Capacity
... View More
The bidder must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years: - Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, - Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, - One similar work costing not less than the amount equal to 60% of advertised value of the tender.
The bidder is required to submit a list of works completed in the last three financial years, giving details such as description of work, organization for whom executed, approximate value of contract at the time of award, date of award, and date of scheduled completion of work. Additionally, the bidder must submit a list of works on hand, indicating description of work, contract value, approximate value of balance work yet to be done, and date of award. Tenderers are required to submit authenticated certificates along with the tenders from officers of government or semi-government/public sector undertakings under whom the work has been executed, indicating the name of work executed, value of works/payment details, and period during which completed.
Costs
EMD
₹ 3,01,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
At Apdj Div : Augmentation Of Electrical Power Distribution System Through Underground Cable Under The Jurisdiction Of Sse/elect/nmz & Sse/elect/east/apdj.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
AP-EL-36-24-25-ALIPURDUAR DIVISION-ELECTRICAL/N F RLYTender No
AP-EL-36-24-25Tender Authority
Northeast Frontier Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & laying of HDPE pipe 100 mm dia of pressure rating 6.0 kgf/ cm2 (PN -6.0) are to be laid along the pole/ beam/brackets by 25x5 mm MS clamp with required nut, bolt/ washer and 4 under the ground by digging trench of depth 1 mtr if necessary. Necessary compression socket and short radius compression bend has to be provided as per direction of Railway Engineer. Cable laying is to done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 is to be done as per specification enclosed at Annexure-A. . Pre- inspection of materials by RITES should be imparted. Make- AJAPLAS, SWASTIK, Prime
9500
293
2792050
... More
Supply & laying of HDPE pipe 63mm dia of pressure rating 6.0 kgf/ cm2 (PN -6.0) are to be laid along the pole/ beam/brackets by 25x5 mm MS clamp with required nut, bolt/ washer and 5 under the ground by digging trench of depth 1 mtr if necessary. Necessary compression socket and short radius compression bend has to be provided as per direction of Railway Engineer. Cable laying is to done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 is to be done as per specification enclosed at Annexure-A. . Pre- inspection of materials by RITES should be imparted. Make- AJAPLAS, SWASTIK, Prime
12300
155
1912404
... More
Excavation of cable trench for laying of cable with necessary cable protection is to be done as per direction of Railway Engineer. The entire work is to be done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 attached at Annexure-A.
36000
131
4741560
... More
Machine boaring is to be done where necessary through HDPE pipe 150mm dia (PN-8) 7 with horizontal boaring of hole across Rly embankment at a depth of 2 mtr below GL by HDD machine. The entire work is to be executed as per direction of Railway Engineer. HDPE pipe Make- AJAPLAS, FINOLEX, SWASTIK
700
4851
3396120
... More
Supply and fixing of aluminum terminal lug for 185 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
64
134
8594.56
... More
Supply and fixing of aluminum terminal lug for 120 sq mm Al. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
980
70
68639.2
... More
Supply and fixing of aluminum terminal lug for 70 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
980
35
34613.6
... More
Supply and fixing of aluminum terminal lug for 50 sq mm Al. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
780
26
20685.6
... More
Supply and fixing of aluminum terminal lug for 35 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
450
16
7452
... More
Supply and fixing of aluminum terminal lug for 25 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
400
12
4864
... More
Supply and fixing of aluminum terminal lug for 16 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
600
6
3750
... More
Supply and fixing of aluminum terminal lug for 10 sq mm AL. XLPE conductors is to be fixing in proper location as per direction of Railway Engineer. Pre-inspection of materials by Railway Engineer should be imparted.
720
4
3254.4
... More
Supply & fixing of cable PVC loop box of 4way terminal (IP: 66) for suitable entry of 16 cable is to be fixed as per direction of Railway Engineer. (Necessary petty items required for successful commissioning to be supplied by contractor). Pre- inspection of materials by RITES should be imparted. Make- Hensel, Rittel, OBO, Schneider
2000
1002
2004000
... More
Supply & laying of FRLSH PVC insulated 2.5sqmm single core multi-stranded copper 17 wire IS:694 to be laid through suitable size rigid conduit pipe (item no. 19) as per direction of Railway Engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make - Finolex, Havells, KEI, Polycab
1500
26
39975
... More
Supply & laying of FRLSH PVC insulated 6sqmm single core multi-stranded copper wire 18 IS:694 to be laid through suitable size rigid conduit pipe (item no. 19) as per direction of Railway Engineer where necessary. Pre- inspection of materials by RITES should be imparted. Make - Finolex, Havells, KEI, Polycab
12000
47
564000
... More
Supply & erection of PVC rigid conduit pipe 25 mm dia medium gauge to be fixed on 19 wall by saddle etc & required size screw at an interval not more than 30 cm with necessary coupler /elbow /Tee / 4way etc as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make- Diamond, Presto Plast, Ajanta Plast
9000
19
174960
... More
Supply & erection of CI pipe 80 mm dia LA type complete with boring below the track/road by 90 mm dia hole at a depth of 1.5 m below GL by turning pointed instrument as per direction of Railway engineer. The CI pipe below the track is required for laying of cable. Pre- inspection of materials by RITES should be imparted. Make - ELECTRO STEEL CASTING LTD, KESHORAM SPUN
-
-
20
... More
Supply & fixing of cable route marker is to be fixed in proper location as per direction of Railway Engineer. The work is to be executed as per instruction of Railway Engineer.
3190
34
111171.5
... More
Cutting of existing rail pole including CC foundation work and fixing of existing street light with proper clamps & others associated items. The work is to be executed as per direction of Railway Engineer.
480
484
232632
... More
Supply & fixing of junction box of 4way terminal (IP: 66) for suitable entry of cable is to 24 be fixed as per direction of Railway Engineer. (Necessary petty items required for successful commissioning to be supplied by contractor). Pre- inspection of materials by Railway Engineer should be imparted. Make- Hensel, Rittel, OBO, Schneider
480
398
191040
... More
Earthing complete with 50mm dia, 3.6mm thickness , B class GI pipe of 3000 mm length to be erected inside an earth pit is to be filled by alternate layers of salt (2) & charcoal (3) of width 50 cm each from the bottom and the rest by earth. The GI strip should be welded with the earth pipe . The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A 25 funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value. The earth fill shall be of homogeneous layer of common earth soil. Where soil resistivity is high, earth resistivity enhancing materials may be used , Bentonite or similar earth enhancing materials may be used in rocky soil. Earth box to be pre casted RCC. The entire earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1, dt. 30.09.2024 attached at annexure-B. The distance of earth electrode form building/other earthing system to be maintained by observing IE rules. Earth electrode to be procured from RDSO/Core approved source.
920
1765
1623846
... More
Supply, installation, testing and commissioning of outdoor feeder pillar box double door including Cu busbar (IP-66) is to be fixed on 48inchx36inchx48inch foundation. The CC foundation is to be done M-15 grade pain cement concrete (Cement content considered @ 240kg/cum). The design and drawing of the foundation should be approved by the competent 26 authority before the execution of the work . The feeder pillar shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Suitable spreader link should be provided with the protection switches of the feeder pillar. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables. Pre-inspection of materials by RITES should be imparted. The feeder pillar shall consists of the followings: i)MCCB 200A, 36kA, 4P =01no, ii) MCCB 125A, 36kA ,4P = 04nos, iii) MCCB 63A, 18kA 4P =02nos, iv) Cu Busbar = 04nos Make : Legrand, LK, ABB, Schneider
50
59023
2951175
... More
Supply, installation, testing and commissioning of outdoor feeder pillar box double door including Cu busbar (IP-66) is to be fixed on 48inchx36inchx48inch foundation. The CC foundation is to be done M-15 grade pain cement concrete (Cement content considered @ 240kg/cum). The design and drawing of the foundation should be approved by the competent 27 authority before the execution of the work . The feeder pillar shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Suitable spreader link should be provided with the protection switches of the feeder pillar. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables. Pre-inspection of materials by RITES should be imparted. The feeder pillar shall consists of the followings: i)MCCB 250A, 36kA, 4P =01no, ii) MCCB 125A, 36kA ,4P =02nos, iii) MCCB 100A, 25kA 4P =02nos, iv) MCCB 63A, 18kA 4P =02nos v)Cu Busbar = 04nos Make : Legrand, LK, ABB, Schneider
20
66823
1336470
... More
Supply, installation, testing and commissioning of outdoor feeder pillar box double door including Cu busbar (IP-66) is to be fixed on 48inchx36inchx48inch foundation. The CC 28 foundation is to be done M-15 grade pain cement concrete (Cement content considered @ 240kg/cum). The design and drawing of the foundation should be approved by the competent authority before the execution of the work . The feeder pillar shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Suitable spreader link should be provided with the protection switches of the feeder pillar. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables. Pre-inspection of materials by RITES should be imparted. The feeder pillar shall consists of the followings: i)MCCB100A, 25kA 4P =01no, ii) MCCB 63A, 18kA 4P =02nos,iii) MCB DP 40A=12nos, iv) Cu. BusBar = 4 nos Make : Legrand, LK, ABB, Schneider
130
41506
5395845
... More
Supply, installation, testing & commissioning of indoor type floor/ wall mounted cubicle type main power panel suitable for 415v.50Hz AC supply made out of 14 SWG CRCA sheet .The panel shall be CPRI approved totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and plugged with insulated &spring loaded thumb screws. The bus bar chamber shall have three phase & neutral copper busbar of ratings not less than 500Amp. The panel shall be completely factory wired with insulated FRLSH copper wire & shall be ready for connection to be equipments. The panel shall be painted with two 29 coats of synthetic enameled grey paint over a coat of red oxide primer. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of panel. Necessary spreader link is to be fixed in proper location as per direction of Railway Engineer. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables. The earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1,dt. 30.09.2024 attached at annexure-B. Pre- inspection of materials by RITES should be imparted. The panel shall consists of the followings : i)MCCB 400A, 50kA ,4P =01no, ii) MCCB 250A, 50kA , 4P =2nos, iii) MCCB 200A, 50kA 4P =02nos,iv) MCCB 63A, 18kA 4P =02nos,v) MCCB 32A, 18kA 4P =02nos, vi) Astro timer switch = 01 no, vii) 50A power contactor = 01 no viii) Digital ammeter, voltmeter with selector switch = 1 set x) Indicator lamp with toggle switch =1 set (RYB) Make : Legrand, LK, ABB, Schneider
3
257185
771555
... More
Supply, installation, testing & commissioning of indoor type (for sub-station) floor/ wall mounted cubicle type main power panel suitable for 415v.50Hz AC supply made out of 14 SWG CRCA sheet .The panel shall be CPRI approved totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and plugged with insulated &spring loaded thumb screws. The bus bar chamber shall have three phase & neutral copper busbar of ratings not less than 500Amp. The panel shall be completely factory wired with insulated FRLSH copper wire & shall be ready for connection to be equipments. The panel shall be 30 painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of panel. Necessary spreader link is to be fixed in proper location as per direction of Railway Engineer. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables.The earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1,dt. 30.09.2024 attached at annexure-B. Pre- inspection of materials by Railway Engineer should be imparted. The panel shall consists of the followings : (i) MCCB 400A, 50kA 4P =01no, ii) MCCB 200A, 50kA ,4P =04nos,iii) MCCB 125A, 36kA 4 P =02nos,iv) MCCB 63A 18kA, 4P=02 nos ,v) MCCB 32A, 18kA 4P =02nos, vi) Astro timer switch = 01 no, vii) 50A power contactor = 01 no. viii) Digital ammeter, voltmeter with selector switch = 1 set x) Indicator lamp with toggle switch =1 set (RYB) Make : Legrand, LK, ABB, Schneider
1
320545
320545
... More
Supply, installation, testing and commissioning of Cu busbar chamber 200A (IP-66) is to be fixed on 48inchx36inchx48inch foundation. The CC foundation is to be done M-15 grade pain cement concrete (Cement content considered @ 240kg/cum). The design and drawing of the 31 foundation should be approved by the competent authority before the execution of the work . The feeder pillar shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Suitable spreader link should be provided with the protection switches of the feeder pillar. Adequate size of rubber grommet is to be provided for incoming & outgoing of cables. Pre-inspection of materials by Railway Engineer should be imparted. Make : Legrand, LK, ABB, Schneider
16
17241
275864
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%