Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Northeast Frontier Railway - NFR Tender

Works
Ireps
Opening Date13 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 62,08,211.63 
Notes
Download

Costs

Summary

At Apdj Div : Provision Of Air Conditioning Machine In Different Offices At Drm Building And Divisional Railway Hospital/apdj.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & laying of FRLSH PVC insulated 2.5sqmm single core multi-stranded copper 4 wire IS:694 to be laid (for connection of individual AC) through suitable size rigid conduit pipe as per direction of Railway Engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make - Finolex, Havells, KEI, Polycab

2500

25

64125

... More
Supply & erection of PVC rigid conduit pipe 25 mm dia medium gauge to be fixed on wall by saddle etc & required size screw at an interval not more than 30 cm with necessary coupler /elbow /Tee / 4way etc as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make- Diamond, Presto Plast, Ajanta Plast

1000

16

16000

... More
Supply, installation, testing & commissioning of indoor type floor/ wall mounted cubicle type main power panel suitable for 415v.50Hz AC supply made out of 14 SWG CRCA sheet .The panel shall be CPRI approved totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and plugged with insulated &spring loaded thumb screws. The bus bar chamber shall have three phase & neutral copper busbar of ratings not less than 500Amp. The panel shall be completely factory wired with insulated FRLSH copper wire & shall be ready for connection to be equipments. The panel shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of panel. Necessary spreader link is to be fixed in proper 6 location as per direction of Railway Engineer. The earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1,dt. 30.09.2024 attached at annexure-B. Pre- inspection of materials by RITES should be imparted. The panel shall consists of the followings : Incomer i) 400A 4P 36KA MCCB with O/L, S/C, E/F Microprocessor Release with communicable by onboard Ethernet, inbuilt energy metering, Both side spreader link, Extended Rotary Handle. Separate LSIG Fault indication on display. The MCCB should be selected for making communication, transmission of measurements, states and alarms from circuit-breaker to system, transmission of events to the system . There should be LED indicating lamp for showing On, OFF, TRIP indication on the panel door etc. = 1 no, 400A 4P Contactor = 1 no, A/M Selector Switch = 1 no Start Stop Push Button = 2no,R,Y,B,On,Off,Trip Indication Lamp = 6 no , 6A SP MCB = 4 no, Outgoing 250A 4P 36KA MCCB with O/L, S/C, E/F Microprocessor Release with communicable by onboard Ethernet, = 4 no , 250A 4P Contactor = 4 no, Start, Stop Push Button = 8 no On, Off Indication Lamp = 8 no, 6A SP MCB = 8 no, Fabrication = 1 no is to be fixed in proper location as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted. Make - Legrand, LK, ABB, Schneider , Havells

1

942517

942517

... More
Supply, installation, testing & commissioning of indoor type floor/ wall mounted cubicle type main power panel suitable for 415v.50Hz AC supply made out of 14 SWG CRCA sheet .The panel shall be CPRI approved totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and plugged with insulated &spring loaded thumb screws. The bus bar chamber shall have three phase & neutral copper busbar of ratings not less than 500Amp. The panel shall be completely factory wired with insulated FRLSH copper wire & shall be ready for connection to be equipments. The panel shall be 7 painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of panel. Necessary spreader link is to be fixed in proper location as per direction of Railway Engineer. The earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1,dt. 30.09.2024 attached at annexure-B is to be fixed in proper location as per direction of Railway Engineer. Pre- inspection of materials by RITES should be imparted. The panel shall consists of the followings : a)MCCB 200A, 4P ,25kA = 1 no b)MCCB 125A 4P, 25kA-04nos, with AL busbar = 1 set c) Digital ammeter, voltmeter with selector switch = 1 set d) Indicator lamp with toggle switch =1 set (RYB) is to be fixed in proper location as per direction of Railway Engineer. Make - Legrand, LK, ABB, Schneider , Havells

7

111860

783020

... More
Supply, installation, testing & commissioning distribution board 8way is to be commissioned as per direction of Railway Engineer. The switch is to be provided on suitable place being observing IE rules & other safety measures. Cable connection to be done by lug /socket of 8 proper size and cable gland to be provided with proper insulation at every cable entrance and exit of distribution board where necessary. Pre- inspection of materials by Railway Engineer should be imparted. The earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1 , dt. 30.09.2024 attached at annexure-B. Pre- inspection of materials by Railway Engineer should be imparted. The board comprising with C series MCCB /MCB's with the following items: a)MCB 4P , 63 A- 01no,b)MCB SP 20A-4nos Make - Legrand, LK, ABB, Schneider , Havells

30

4219

126570

... More
Laying of cable is to be done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 as per specification enclosed at Annexure-A. (Alluminium LT XLPE armoured cable will be procured through store).

2000

9

18380

... More
Supply, installation, testing & commissioning of outdoor type LT cable termination kit 10 for successful commissioning of LT cables as per direction of Railway Engineer where necessary. Pre-inspection of materials by Railway Engineer should be imparted. Make- Denson/Raychem/3M/Compaq.

2

1941

3882.32

... More
Supply & laying of FRLSH PVC insulated 6sqmm single core multi-stranded copper wire 11 IS:694 to be laid through suitable size rigid conduit pipe as per direction of Railway Engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make - Finolex, Havells, KEI, Polycab

5500

47

258500

... More
Supply & erection of PVC rigid conduit pipe 32 mm dia medium gauge to be fixed on 12 wall by saddle etc & required size screw at an interval not more than 30 cm with necessary coupler /elbow /Tee / 4way etc as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make- Diamond, Presto Plast, Ajanta Plast

1000

39

39000

... More
Supply & laying of FRLSH PVC insulated 1sqmm single core multi-stranded copper wire 13 IS:694 to be laid through (for earth continuity) suitable size rigid conduit pipe as per direction of Railway Engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make - Finolex, Havells, KEI, Polycab

3000

14

42000

... More
Supply & fixing of water proof busbar (IP; 66) chamber consists with 4nos Alluminium 14 busbar suitable for cable entry of 4 nos with necessary PVC gland etc is to be fixed in proper location as per direction of Railway Engineer. (Fabrication & others necessary petty work for fixing of busbar is to be done by the contractor by his own cost). Pre- inspection of materials by Railway Engineer should be imparted.

42

9675

406350

... More
Supply & fixing of GI wire 8SWG covered with PVC alkathene pipe is to be fixed in proper location as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted.

600

20

12000

... More
Supply & fixing of GI wire 6SWG covered with PVC alkathene pipe is to be fixed in proper location as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted.

300

16

4800

... More
Supply & fixing of Alluminium busbar 30cm x 4cm and 3mm thick with suitable water 17 proof enclosure fixed with insulator for connection of earth continuity wire is to be fixed in proper location as per direction of Railway Engineer. (Fabrication & others necessary petty work for fixing of busbar is to be done by the contractor by his own cost). Pre- inspection of materials by Railway Engineer should be imparted.

30

550

16500

... More
Supply & fixing of cable junction box/PVC loop box of 4way terminal (IP:65/66) for 18 suitable entry of cable is to be fixed where necessary as per direction of Railway Engineer. (Necessary petty items required for successful commissioning to be supplied by contractor). Pre- inspection of materials by Railway Engineer should be imparted. Make- Hensel, Rittel, OBO, Schneider

30

735

22050

... More
Laying of cable is to be done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 as per specification enclosed at Annexure-A. (HT cable will be procured through store).

1000

9

9190

... More
Supply, installation, testing & commissioning of outdoor type HT cable termination kit 20 for successful commissioning of HT cable (95sqmm 3 core) as per direction of Railway engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make- Denson/Raychem/3M/Compaq.

12

16460

197520

... More
Supply & erection of HDPE pipe 110 mm dia of pressure rating 6.0 kgf/ cm2 (PN -6.0) are to be laid along the pole/ beam/brackets by 25x5 mm MS clamp with required nut, bolt/ washer and under the ground by digging trench of depth 1 mtr if necessary. Necessary compression socket 21 and short radius compression bend has to be provided as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Cable laying is to done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 is to be done as per specification enclosed at Annexure-A. . Pre- inspection of materials by RITES should be imparted. Make- AJAPLAS, SWASTIK, Prime

1600

341

547008

... More
Excavation of cable trench for laying of cable with necessary cable protection is to be done as per direction of Railway Engineer. The entire work is to be done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 attached at Annexure-A.

800

131

105368

... More
Installation and commissioning of 11/0.433 KV, 500 KVA outdoor type step down 23 transformer as per direction of Railway Engineer. (Loading, unloading & carrying of transformer to actual work site by contractor own arrangement, necessary others petty items should be supplied by contractor for successful commissioning). (Transformer will be procured through Store)

1

55000

55000

... More
Dismantling and re-shifting of existing 150 KVA transformer with all associated items 24 is to be done as per direction of Railway Engineer. The existing transformer should be dismantled properly and the dismantled transformer along with all accessories should bring and re- commissioned at new location as per direction of Railway Engineer at its own cost by the contractor.

2

30000

60000

... More
RCC foundation as per M25 grade with minimum cement concrete of 330kg/cum, providing & laying in position ready mixed or site batched design mixed cement concrete or reinforce cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, 25 Portland pozzolana /ordinary /Portland /Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/retard setting of concrete , to improve durability and workability without impairing strength; including pumping of concrete to site of lying, curing, carriage for all leads; shuttering work is also involve. The work is to be done as per direction of Railway engineer.

40

8683

347352

... More
Supply & stringing of longitudinal guard wire with cross lacing by 8/10 SWG GI wire at an interval of 1mtr to be stringed with the guard bracket fixed on the pole as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted.

4000

8

35760

... More
Construction of fencing for surrounding of transformer of suitable height RCC pillar 27 with muffing and to be completed by expended metal and MS channel and one door of suitable size for entrance. Area within the fencing to be covered with gravels. The entire work is to be executed as per direction of Railway Engineer.

1

51880

51880.5

... More
Supply & fixing of 11 KV, GO/DO air break Switch 3 insulator type complete with 28 handle, pipe, square bar, 400A rotating/tilting type & all mechanical fittings to be installed by instruction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make- ATLAS / MAYUR / JAYSHREE/ JAIPURIA

20

15269

305382.2

... More
Supply & fixing of MS angle of size 50x50x6 & length 2.2 mtr long as per the direction 29 of Railway Engineer & to be fixed on the pole by suitable MS clamp and suitable size MS nuts, bolts & washers including making of holes by drilling machine. The bracket, clamp and nuts, bolts are to be painted by 1 coat of red oxide as primer and 2 coats of aluminum paint. Tenderer shall be supplied the paints. Pre- inspection of materials by Railway Engineer should be imparted.

140

170

23840.6

... More
Supply & fixing of MS channel made by 75x40x40x6mm & length 2.2 mtr long as per 30 the direction of EIC at site & to be fixed on the pole by 65x 6 mm MS clamp and suitable size MS nuts, bolts & washers including making of holes by drilling machine. The bracket, clamp and nuts, bolts are to be painted by 1 coat of red oxide primer and 2 coats of aluminum paint. Tenderer shall be supplied the paints. Pre- inspection of materials by Railway Engineer should be imparted.

180

621

111925.8

... More
Supply & fixing of MS channel made by 75x40x40x6mm & length 2.2 mtr long as per 31 the direction of EIC at site & to be fixed on the pole by 65x 6 mm MS clamp and suitable size MS nuts, bolts & washers including making of holes by drilling machine. The bracket, clamp and nuts, bolts are to be painted by 1 coat of red oxide primer and 2 coats of aluminum paint. Tenderer shall be supplied the paints. Pre- inspection of materials by Railway Engineer should be imparted.

100

160

16000

... More
Supply & fixing of 2P composite polymer HT 11 KV pin insulator (10KN) IS : 731 (1971) 32 & 2488 (Pt-II) 1974 with galvanized bolts has to be erected on the top of the pole by necessary GI pipe washer etc as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make - COMPAQ, JAYSREE , MAYUR , ATLAS, JAIPURIA

40

258

10327.2

... More
Supply & fixing of 2P composite polymer type HT 11 KV disc insulator (70KN),IS : 731 33 (1971) & 2488 (Pt-II) 1974 has to be erected on the top of the pole by necessary fixing arrangement as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make - COMPAQ, JAYSREE , MAYUR, ATLAS, JAIPURIA.

25

304

7611.25

... More
Supply & fixing of HT galvanized stay set comprising of 20 mm dia stay rod, anchor 34 plate ,turn buckle , thimble, MS stay clamp with nut bolt and washer ; 7/10 SWG GI stay wire ; stay insulator to be fixed with the pole at one end and with the rod at the other end. The stay rod should be erected after excavating the earth of dia 30 cm with refilling by cement concrete mixture in ratio of 1:3:6 as per direction of Railway Engineer. Pre- inspection of materials by Railway Engineer should be imparted. Make- ATLAS / MAYUR / JAYSHREE/ JAIPURIA

12

760

9120.48

... More
Supply & stringing of ACSR (Weasel) of size 6/1/2.59mm to be stringed over pin and 35 shackle insulator with necessary aluminum wire binding and jumpering. Jointing must not be done in mid span. Pre- inspection of materials by Railway Engineer should be imparted. Make - JAYSREE, MAYUR, ATLAS, JAIPURIA

500

20

10235

... More
Supply, fixing, testing and commissioning of distribution class lightening arrestor 36 suitable for 11 K.V O.H with rated voltage 9 KV (RMS) and a normal discharge current rating of 5 KA complete. Pre- inspection of materials by Railway Engineer should be imparted. Make- ELPRO / Raychem/JAYSHREE/ Thyrister

20

437

8750.6

... More
Supply & erection of GI tubular pole of 12mtr long as per the following specification : 37 Bottom 165 mm O/D x 4.85 mm thick Middle 139 mm O/D x 4.85 mm thick. Top 114 mm O/D x 4.85 mm thick (Test certificate & warrantee certificate from the manufacturer is to be produced by the contractor at the time of billing). Pre- inspection of materials by Railway Engineer should be imparted. Make- Bajaj, Philips, Utkarsh , Crompton

20

13045

260915.2

... More
Laying of cable (Signal office to opposite track site) is to be done as per drawing no. PCEE/ELG/DRG/2024/2, dt. 04.10. 2024 as per specification enclosed at Annexure-A. (HT cable will be procured through store).

500

9

4595

... More
Supply, installation, testing & commissioning of outdoor type HT cable termination kit 39 for successful commissioning of HT cables (150sqmm 3 core) as per direction of Railway engineer where necessary. Pre- inspection of materials by Railway Engineer should be imparted. Make- Denson/Raychem/3M/Compaq.

2

17662

35324

... More
Track crossing with machine boring with 150 mm dia (PN -8) HDPE pipe with 40 horizontal boring of hole across Rly embankment at a depth of 2 mtr below GL by HDD machine. The entire work is to be executed as per direction of railway Engineer. HDPE pipe Make- AJAPLAS, FINOLEX, SWASTIK

200

4851

970320

... More
Earthing complete with 50mm dia, 3.6mm thickness , B class GI pipe of 3000 mm length to be erected inside an earth pit is to be filled by alternate layers of salt (2) & charcoal (3) of width 50 cm each from the bottom and the rest by earth. The GI strip should be welded with the earth pipe . The pipe is provided with a tapered casing at the lower end in order to facilitate the 41 driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing materials may be used , Bentonite or similar earth enhancing materials may be used in rocky soil. Earth box to be pre casted RCC. The entire earthing system is to be done as per drawing no. PCEE/ELG/DRG/2024/1, dt. 30.09.2024 attached at annexure-B. The distance of earth electrode form building/other earthing system to be maintained by observing IE rules. Earth electrode to be procured from RDSO/Core approved source.

40

1765

70602



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.