North Bengal Development Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

North Bengal Development Department - NBDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Dec 2024
Closing Date31 Dec 2024
Tender Amount₹ 39,79,172 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and fitting joints with powdered earth or local sand.

106.23

383

40767.38

... More
(I) Cement concrete with graded stone ballast (40 mm size) excluding shuttering in floor and foundation. (B) With N.B. Variety stone metal. (a) (6:3:1) proportion

10.62

4262

45285.46

... More
Brick work with 1st class bricks in cement mortar (6:1) . a) In Foundation and plinth

7.34

5835

42832.93

... More
Anti-termite treatment to the outside of foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight, drilling 12mm. dia holes in concrete or masonry apron at an interval of 300mm. to a depth, of 300mm or more as close to the plinth wall as possible and the chemical emulsion pumped into those holes to soak the soil below at a rate of 2.25 litres per linear metre complete as per specification laid down in para 4.3.1.1 of Code I.S.- 6313 (Part-III)-1981. a) In Foundation and plinth

41.73

85

3580.51

... More
Anti-termite treatment to the soil under floor with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight including drilling vertically 12mm. dia holes at the junction of floor and wall at 300m interval to reach the soil below using hand operated pressure pump to squirt chemical emulsion into the pump to squirt chemical emulsion into the holes at the rate of one litre per hole. The holes shall be sealed after operation to match with the existing floor. The entire work is to be carried out as per specification laid down in para 4.3.1.4 of code I.S.- 6313 (Part-III)-1981. a) In Foundation and plinth

56.91

110

6307.86

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).

3.2

241

774.34

... More
Brick work with 1st class bricks in cement mortar (6:1) . b) In Super Structure. i) In Ground Floor.

3.01

6045

18205.59

... More
125mm thick brick work in cement mortar (4:1) in ground floor In Ground Floor :-

73.16

794

58101.88

... More
125mm thick brick work in cement mortar (4:1) in ground floor In First Floor :-

58.16

808

47019.31

... More
125mm thick brick work in cement mortar (4:1) in ground floor In Second Floor :-

58.16

822

47851.11

... More
125mm thick brick work in cement mortar (4:1) in ground floor In Third Floor :-

20.3

837

16987.66

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Ground Floor :-

48.35

5443

263174.28

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In First Floor :-

22.81

5556

126749.61

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Second Floor :-

22.81

5669

129332.36

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. In Third Floor :-

6.3

5782

36448.37

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, omplete as per drawing and direction. (i) Tor steel/Mild Steel In G.F.

6.07

73071

443739.4

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, omplete as per drawing and direction. (i) Tor steel/Mild Steel In F.F.

3.31

73583

243768.3

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, omplete as per drawing and direction. (i) Tor steel/Mild Steel In F.F.

0.92

74096

67822.68

... More
Hire and labour charges for shuttering with entering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns,lintels curved or straighting Upto PL a) 25 mm.to 30mm thick wooden shuttering as per.

92.34

390

36095.69

... More
Hire and labour charges for shuttering with entering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns,lintels curved or straighting Above PL. Ground Floor a) 25 mm.to 30mm thick wooden shuttering as per.

158.23

390

61854.53

... More
Hire and labour charges for shuttering with entering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns,lintels curved or straighting First Floor a) 25 mm.to 30mm thick wooden shuttering as per.

158.23

412

65248.99

... More
Hire and labour charges for shuttering with entering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns,lintels curved or straighting Second Floor a) 25 mm.to 30mm thick wooden shuttering as per.

157.03

433

68122.87

... More
Hire and labour charges for shuttering with entering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns,lintels curved or straighting Above PL. Third Floor a) 25 mm.to 30mm thick wooden shuttering as per.

18.6

455

8469.8

... More
Wood work in door and window frames fitted and fixed complete, including a protective coat of painting at the contact surface of the frame. (c) Sal : Siliguri.

0.91

97651

88801.67

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf)

24.79

3169

78551.49

... More
M.S. or W.I. Ornamental grill of approved design joints contiously welded with M.S., W.I. Flats and bars for windows railing etc. fitted and fixed with necessary screws and lugs in ground floor. 1)Grill weighing above 10Kg/sq.m. and upto 16 Kg/sq.m.

194.4

119

23217.25

... More
M.S. clamp for door and window frame made of flat bar, and bifurcated, fixed in cement concrete with stone chips (4:2:1) fitted and fixed complete as per design. A) 40x6x250mm

50

34

1728.11

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. vii) 100mm long x 58mm x 1.90mm thick

50

56

2800.73

... More
Iron socket bolt of approved quality fitted and fixed complete. b) 150mm longx10mm dia bolt

30

75

2252.5

... More
Anodised aluminium "D" type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete. a) with continuous plate base(hexagonal/round rod) v) 150mm gripx10mm dia rod.

25

115

2890.12

... More
Iron hasp bolt of approved quality fitted & fixed complete. c) 300 mm long

5

197

989.19

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)

20

10817

216359.37

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (ground floor) (ii) With 1:4 cement mortar (Inside) (b) 15 mm thick plaster

77.33

183

14160.03

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (ground floor) (ii) With 1:4 cement mortar (out Side) (a) 20 mm thick plaster

99.43

210

20919.27

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (ground floor) a) With (4:1) cement mortar (Celing) I) 10mm thick plaster.

178.72

147

26362.9

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (First floor) (ii) With 1:4 cement mortar (Inside) (b) 15 mm thick plaster

63.67

187

11963.44

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (First floor) (ii) With 1:4 cement mortar (out Side) (a) 20 mm thick plaster

63.67

215

13700.47

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (First floor) a) With (4:1) cement mortar (Celing) I) 10mm thick plaster.

178.72

152

27214.89

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Second floor) (ii) With 1:4 cement mortar (Inside) (b) 15 mm thick plaster

66.79

192

12866.48

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Second floor) (ii) With 1:4 cement mortar (out Side) (a) 20 mm thick plaster

106.55

219

23434.1

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Second floor) a) With (4:1) cement mortar (Celing) I) 10mm thick plaster.

178.72

157

28066.89

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Third floor) (ii) With 1:4 cement mortar (Inside) (b) 15 mm thick plaster

19.47

197

3844.79

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Third floor) (ii) With 1:4 cement mortar (out Side) (a) 20 mm thick plaster

65.65

224

14751.97

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surfece, including throating, nosing and drip course wherer necessary (Third floor) a) With (4:1) cement mortar (Celing) I) 10mm thick plaster.

8

161

1294.49

... More
Neat cement punning about 1.5mm thick in wall dado, window, sills, floor, drain etc.

34.63

39

1350.74

... More
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below ortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White

250.99

2011

504924.24

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) G.F.

355.47

145

51685.63

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) F.F.

306.07

146

44761.08

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) S.F.

352.06

147

51784.61

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) T.F.

93.13

147

13776.92

... More
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor). (b) Two Coats. i) Water based interior grade Acrylic Primer

771.42

5267

40636.62

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats). i) Standard Quality.

771.42

73

57001.59

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats

335.3

5375

18022.49

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat). b) Premium 100% Acrylic Emulsion.

335.3

100

33567.39

... More
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

64.35

45

2914.31

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : (iv) Two coats (with any shade except white)

64.35

96

6212.08

... More
(a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.

12.15

34

419.93

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : (iv) Two coats (with any shade except white)

12.15

94

1143.95

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming toIS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat asper design, drawing & direction of Engineerin-Charge complete including cutting to requisite shape & size, fabrication includingmetal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erectionall complete.The rate includes the cost of all M.S. Hollowsection, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and allincidental chages (such as electricity, labourinsurance) etc. complete.Payment to be made on the basis ofcalculated weight of structural memebrs of MS Holow Section as specified in relevent IScode in finished work. Payment for gusset,bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For roof truss works.a) Span up to 12 Mtr

3.92

88531

347044.15

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet

196

1067

209299.15

... More
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) (A) 300 mm lapping each way (a) With 0.60 mm sheet

15

436

6542.98

... More
Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping) (b) 300 mm. wide gutter

70

479

33537.25



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.