North Bengal Development Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
North Bengal Development Department - NBDD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Sep 2024
Closing Date23 Sep 2024
Tender Amount₹ 33,90,765 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Niq-03-(el) (sl-03) Of 2024-2025
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NBDD_746658_3Bid Award Id
ViewTender No
NBDD/BS/SE /NIQ-03 - (EL) of 2024-2025Tender Authority
North Bengal Development Department ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supplying and fixing 25 mm PVC Rigid Conduit 'FR' on wall, ceiling with saddles and other accessories as required
and mending good damages to building works
325
-
-
... More
Supplying and Drawing 1.1 KV single core stranded 'FR'
PVC insulated & unsheathed single core stranded copper wire
(Brand approved by EIC) of the following sizes in the prelaid
polythene pipe and by the prelaid GI fish wire and making
necy. connection as required 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
200
-
-
... More
Supplying and Drawing 1.1 KV single core stranded 'FR'
PVC insulated & unsheathed single core stranded copper wire
(Brand approved by EIC) of the following sizes in the prelaid
polythene pipe and by the prelaid GI fish wire and making
necy. connection as required2×10 sq.mm. + 1×6 sq.mm.
25
-
-
... More
Distribution wiring in 1.1 KV single core stranded 'FR'
PVC insulated & unsheathed copper wire (Brand
approved by EIC) in 20mm size PVC rigid conduit 'FR'
(Precision make) incl. necy. fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
100
-
-
... More
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'
PVC insulated & unsheathed single core stranded copper wire (Make-KEI/Havells/RR Cables) in 19 mm bore, 3 mm thick polythen
pipe complete with all accessories embedded in wall to
light/fan/call bell points with Modular type switch (Make-Legrand/Havells/L&T) fixed on Modular GI switch board with top
cover plate flushed in wall incl. mending good damages to
original finish a) Avg run 8 mtr.
4
-
-
... More
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug
socket (Make-Legrand/Havells/L&T) with 6A Modular type
switch, without plug top on 4 Module GI/PVC Modular type
switch board with 3 Module top cover plate flushed in
wall incl. S&F switch board and cover plate and making
necy. connections with PVC Cu wire and earth continuity
wire etc.
5
-
-
... More
Supply of LED Bulkhead that fits in vartiety of applications and serves as simple energy efficient alternative to CFL/incandescent bulkhead luminaires. (Havells/Crompton/HPL)
4
-
-
... More
Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc.
4
-
-
... More
Earthing with Copper plate (610x610x3mm size) having weight
of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1
no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long)
incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt.
long) to be fillied with bitumen, partly under the ground level &
partly above ground level to an average depth of 3.65 Mts.
below the ground level and restoring the surface duly rammed
incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for
periodic treatment, incl. providing masonery enclosure on the
top of the earth electrode of overall size 86.36x86.36x46cm
deep (below Ground level) complete with cemented brick work
(1:6) of 25 cm width, duly plastered with cement morter
(inside) CI hinged inspection cover of size 36.56x35.56cm
with locking arrangement, GI reducer and treatment of soil by
using salt & charcoal or coke for plate electrode
1
-
-
... More
Dismantling all types of masonry excepting cement
concrete plain or reinforced, stacking serviceable
materials at site and removing rubbish as directed
within a lead of 75 m. a) In ground floor including roof. Basement floor (Lift room)
2.06
-
-
... More
Ground floor Lift room
2.06
-
-
... More
1st floor( Lift room)
2.06
-
-
... More
2nd floor (Lift room)
2.06
-
-
... More
Labour for Chipping of concrete surface before taking up
Plastering work.
107.24
-
-
... More
Page- 164, Item -2 P.W.(Bild)Schedule -Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar b) 15 mm thick plaster Basement floor
26.81
-
-
... More
Ground floor
26.81
-
-
... More
1st floor
26.81
-
-
... More
2nd floor
26.81
-
-
... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
20
-
-
... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River
6.26
-
-
... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL.
0.74
-
-
... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. i) For roof truss works a) Span up to 12 Mtr
0.78
-
-
... More
Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of tiles@ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] Area of each slab upto 0.2 Sq.m
27
-
-
... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and
as per direction of the EIC. (In Ground Floor)(a) one Coats (i) Water based interior grade Acrylic Primer
27
-
-
... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty
(to be done under specific instruction of Superintending Engineer) : (Two coats) i) Luxury Quality.
27
-
-
... More
White washing including cleaning and smoothening surface thoroughly. All floors :b) Two coats (to be done on specific instruction). Basement floor, lift well
119.25
-
-