Municipal Affairs Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Municipal Affairs Department - MAD Tender

Works
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date24 Jan 2025
Closing Date22 Feb 2025
Tender Amount₹ 66,21,908 
Notes
Download

Costs

Summary

Supply Laying Distribution Network ( Hdpe Pipe And Di K-7 Pipe) With All Other Associated Works Excluding Cost Of Road Restoration For 64.17 Km At Zone-2 To Be Completed In All Respect Within Gangarampur Municipality For Water Supply Scheme Under

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
f) 160mm(OD)

861

911

784371

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). B) For UPVC/HDPE Pipe c)110 mm (OD)

47148

3

178219.44

... More
d) 125mm(OD)

637

3

2433.34

... More
f) 160mm(OD)

861

4

4115.58

... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).B) For UPVC/HDPE Pipe, c)110 mm (OD)

47148

1

50919.84

... More
d) 125mm(OD)

637

1

789.88

... More
f) 160mm(OD)

861

1

1489.53

... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)

486.46

118

57402.28

... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the with drawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) 110 mm dia (OD) to 160 mm dia (OD)

297.59

1023

304434.57

... More
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) 110 mm dia (OD) to 160 mm dia (OD)

2991.49

939

2809009.11

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. Total = Road dismantling qnty.110 mm dia (OD) to 160 mm dia (OD)

3289.08

166

545987.28

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM² and body tested to 15kg/CM², flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. 100 mm dia

96

5067

486432

... More
150 mm dia

2

7487

14974

... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 80 mm to 150 mm dia pipe

98

11990

1175020

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies. B) For UPVC/HDPE Pipe

48646

-

18485.48

... More
Add GST @ 18%

1

5078718

5078718.96

... More
Add labour welfare cess @ 1%

1

332938

332938.24

... More
DI-K7 pipes Laying in Distribution system for Proposed water supply scheme

-

-

-

... More
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc. without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. 100 mm dia Pipe

10326

72

743472

... More
150 mm dia Pipe

2747.5

112

307720

... More
200 mm dia Pipe

208.5

136

28356

... More
250 mm dia Pipe

1477

164

242228

... More
300 mm dia Pipe

409

192

78528

... More
350 mm dia Pipe

189.5

225

42637.5

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source). 100 mm dia Pipe

10431

3

34735.23

... More
150 mm dia Pipe

2775

4

11655

... More
200 mm dia Pipe

211

5

1183.71

... More
250 mm dia Pipe

1492

6

9936.72

... More
300 mm dia Pipe

414

7

2989.08

... More
350 mm dia Pipe

192

7

1472.64

... More
Cleaning thoroughly the inner surface of pipe line including specials andvalves by flushing with water and subsequently disinfection of the samepipe line by flushing again with water containing bleaching powderresulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of suchfilling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. Therates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). 100 mm dia Pipe

10431

-

9805.14

... More
150 mm dia Pipe

2775

1

4273.5

... More
200 mm dia Pipe

211

2

502.18

... More
250 mm dia Pipe

1492

3

5177.24

... More
300 mm dia Pipe

414

4

1987.2

... More
350 mm dia Pipe

192

6

1221.12

... More
Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC. a) 80mm.dia. to 125mm.dia pipe

104

109

11336

... More
b) 150mm.dia.to 200mm.dia pipe

30

141

4230

... More
c) 250mm.dia.to 350mm.dia pipe

21

263

5523

... More
Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete as per direction of EIC. 100 mm dia Pipe

208

82

17056

... More
150 mm dia Pipe

56

108

6048

... More
200 mm dia Pipe

4

113

452

... More
250 mm dia Pipe

30

120

3600

... More
300 mm dia Pipe

8

160

1280

... More
350 mm dia Pipe

4

185

740

... More
Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW rate). 100 mm dia Pipe

42

182

7644

... More
150 mm dia Pipe

12

220

2640

... More
200 mm dia Pipe

2

237

474

... More
250 mm dia Pipe

6

329

1974

... More
300 mm dia Pipe

2

351

702

... More
350 mm dia Pipe

2

448

896

... More
All Types of D.I Ductile Iron (D.I) specials (viz. Bend, Tee, Taper, Tail piece etc), size conforming to IS specification No 9523/2000 With Cement mortar lining (inside) and bituminous coating (outside) (25% of payment will be held up till successful hydraulic testing) a) All socket Tee 100 mm dia. to 300 mm. dia.

3478.2

128

445209.6

... More
350mm to 450mm dia.

261

159

41499

... More
b) Double socketed bend, 100 mm dia. to 300 mm. dia.

5850.1

125

731262.5

... More
350mm to 450mm dia.

388

154

59752

... More
c)   Tail piece, 100 mm dia. to 300 mm. dia.

1650.2

144

237628.8

... More
350mm to 450mm dia.

104

185

19240

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM² and body tested to 15kg/CM², flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. 100 mm dia

21

5067

106407

... More
150 mm dia

5

7487

37435

... More
250 mm dia

3

20429

61287

... More
300 mm dia

1

24205

24205

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut inside screw non- rising spindle type gunmetal/AISI 410 suitable for PN 1.0 rating complete with ball thrust bearing and enclosed gearbox (EN-8 with hardened by nitriding pinions of EN-19), flanges flat faced and drilled to IS.: 1538 : 1993. Valves tested by closed end method. 350 mm dia

2

94478

188956

... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]i) 80 mm to 150 mm dia pipe

26

11990

311740

... More
iii) 250 mm to350 mm dia pipe

6

18881

113286

... More
Construction of Thrust Block 300 mm dia Pipe

9

4952

44571.06

... More
350 mm dia Pipe

6

8045

48273.78

... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the with drawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC. (width cutting for trench as per IS 3114 : 2004 , P-1, Cl-3.2) 100 mm dia Pipe TO 300 mm dia Pipe & 350 MM DIA PIPE

839.07

1023

858368.61

... More
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) 150 mm dia Pipe TO 250 mm dia Pipe

62.2

939

58405.8

... More
Removal of rubbish, earth etc. From the working site and disposal of the same beyond the compound, in conformity with the Municipal/ Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer-In-Charge. 100 mm dia Pipe TO 350 mm dia Pipe

901.27

166

149610.82

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.

15515

-

5895.7

... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)

155.15

118

18307.7

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.

4.36

5858

25566.62

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness and required bracing for concrete slabs, beams, column lintel curved or straight including fitting, fixing and striking out after completion of woks (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation

34.91

205

7156.55

... More
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars stirrups, binders etc initial straighting and removal losse rust if necessary cutting requiste length hooking and bending to correct shape placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (i) Tor steel/Mild Steel.

0.34

61751

21155.95

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

5.82

4919

28633.59

... More
Laying Cost of M.S pipe 100 mm dia Pipe

105

359

37695

... More
150 mm dia Pipe

27.5

564

15520.45

... More
200 mm dia Pipe

2.5

929

2323.8

... More
250 mm dia Pipe

15

1118

16773.45

... More
300 mm dia Pipe

5

1755

8775.4

... More
350 mm dia Pipe

2.5

2267

5668.45

... More
Add GST on 2 @ 18%

1

958155

958155.46

... More
Supply Cost of DI-K7 & M.S Pipe

-

-

-

... More
Supply & Delivery (at Site) of DI K-7 Pipes conforming to I.S-8329:2000. Included 18% GST 100 mm dia Pipe

10326

1287

13289562

... More
150 mm dia Pipe

2747.5

1858

5104855

... More
200 mm dia Pipe

208.5

2367

493519.5

... More
250 mm dia Pipe

1477

3118

4605286

... More
300 mm dia Pipe

409

3944

1613096

... More
350 mm dia Pipe

189.5

4809

911305.5

... More
Supply of M.S pipe Including Coating including 18% G.S.T 100 mm dia Pipe

105

1712

179774.7

... More
150 mm dia Pipe

27.5

2505

68892.73

... More
200 mm dia Pipe

2.5

3812

9531.4

... More
250 mm dia Pipe

15

4398

65977.5

... More
300 mm dia Pipe

5

5714

28572.45

... More
350 mm dia Pipe

2.5

6738

16846.95

... More
Add labour welfare cess on 2 and 3 @ 1%

1

326684

326684.61



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.