Municipal Affairs Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Municipal Affairs Department - MAD Tender

Works
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date24 Jan 2025
Closing Date22 Feb 2025
Tender Amount₹ 6,28,56,406 
Notes
Download

Costs

Summary

Supply Laying Distribution Network ( Hdpe Pipe And Di K-7 Pipe) With All Other Associated Works Excluding Cost Of Road Restoration For 57.95 Km At Zone-1 To Be Completed In All Respect Within Gangarampur Municipality For Water Supply Scheme Under

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
e) 140mm(OD)

1907

722

1376854

... More
f) 160mm(OD)

1304

911

1187944

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).B) For UPVC/HDPE Pipe, c)110 mm (OD)

44219

3

167147.82

... More
d) 125mm(OD)

1831

3

6994.42

... More
e) 140mm(OD)

1907

4

8085.68

... More
f) 160mm(OD)

1304

4

6233.12

... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).B) For UPVC/HDPE Pipe, c)110 mm (OD)

44219

1

47756.52

... More
d) 125mm(OD)

1831

1

2270.44

... More
e) 140mm(OD)

1907

1

2746.08

... More
f) 160mm(OD)

1304

1

2255.92

... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)

492.61

118

58127.98

... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking up the with drawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) 110 mm dia (OD) TO 160 mm dia (OD) Pipe

285.05

1023

291606.15

... More
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) 110 mm dia (OD) TO 160 mm dia (OD) Pipe

3088.14

939

2899763.46

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. Total = Road dismantling qnty. 110 mm dia (OD) TO 160 mm dia (OD) Pipe

3373.19

166

559949.54

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM² and body tested to 15kg/CM², flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. 100 mm dia

92

5067

466164

... More
150 mm dia

6

7487

44922

... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified] i) 80 mm to 150 mm dia pipe

98

11990

1175020

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies. B) For UPVC/HDPE Pipe

49261

-

18719.18

... More
Add GST @ 18%

1

5306089

5306089.74

... More
Add labour welfare cess @ 1%

1

347843

347843.66

... More
DI-K7 pipes Laying in Distribution system for Proposed water supply scheme

-

-

-

... More
Carrying CI/DI pipes with specials and valves and lowering placing in position and laying carefully inside the trenches in proper alignment and gradient etc. including earth work in excavation of adequate width as per specification having min. clear cover from top of pipe is 1.10mtr. below existing ground level in any kind of soil including mixed with boulder, road sub-grade and its flank,but excluding moorum and laterite and stone etc. without damaging the exisiting telephone/electric cable etc.(in case of damaged if any type of cable line during excecution , necessary damaged charges as applicable by the respective authority will be borne by the agency in his own cost) preparing the bottom surface for continuous bedding of pipe line and laying pipes, fitting, fixing specials and valves with bailing out water if any including carriage of pipes, specials and valves from local deptt. store within 8KM and back filling the trenches with excavated earth in layers to original condition as per specification and direction of EIC. The surplus materials after execution of work are to be return to the deptt. store. 100 mm dia Pipe

2802.5

72

201780

... More
150 mm dia Pipe

1472

112

164864

... More
200 mm dia Pipe

1279.5

136

174012

... More
250 mm dia Pipe

1379

164

226156

... More
300 mm dia Pipe

701.5

192

134688

... More
350 mm dia Pipe

713.5

225

160537.5

... More
400 mm dia Pipe

248.5

260

64610

... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source) 100 mm dia Pipe.

2830

3

9423.9

... More
150 mm dia Pipe

1487

4

6245.4

... More
200 mm dia Pipe

1292

5

7248.12

... More
250 mm dia Pipe

1394

6

9284.04

... More
300 mm dia Pipe

709

7

5118.98

... More
350 mm dia Pipe

721

7

5530.07

... More
400 mm dia Pipe

251

8

2226.37

... More
Cleaning thoroughly the inner surface of pipe line including specials andvalves by flushing with water and subsequently disinfection of the samepipe line by flushing again with water containing bleaching powderresulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of suchfilling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. Therates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).100 mm dia Pipe

2830

-

2660.2

... More
150 mm dia Pipe

1487

1

2289.98

... More
200 mm dia Pipe

1292

2

3074.96

... More
250 mm dia Pipe

1394

3

4837.18

... More
300 mm dia Pipe

709

4

3403.2

... More
350 mm dia Pipe

721

6

4585.56

... More
400 mm dia Pipe

251

8

2050.67

... More
Cutting DI pipe (all class & type) to required length with cutting device etc. and grinding the cutting portion with file as per direction and satisfaction of EIC. a) 80mm.dia. to 125mm.dia pipe

28

109

3052

... More
b) 150mm.dia.to 200mm.dia pipe

28

141

3948

... More
c) 250mm.dia.to 350mm.dia pipe

28

263

7364

... More
d) 400mm.dia.to 450mm.dia pipe

3

385

1155

... More
Chamfering the spigot end of all type/class of DI pipe for proper using of push joint by means of grinder set at site for proper joint etc. all complete as per direction of EIC. 100 mm dia Pipe

56

82

4592

... More
150 mm dia Pipe

30

108

3240

... More
200 mm dia Pipe

26

113

2938

... More
250 mm dia Pipe

28

120

3360

... More
300 mm dia Pipe

14

160

2240

... More
350 mm dia Pipe

14

185

2590

... More
400 mm dia Pipe

12

209

2508

... More
Making flange joint to DI/CI pipes, specials and valves where necessary with supply of required rubber insertion and nut bolts, washers etc. of approved quality and type all complete as per specification and direction of EIC (Nut and bolts shall be of TATA/GKW rate). 100 mm dia Pipe

12

182

2184

... More
150 mm dia Pipe

6

220

1320

... More
200 mm dia Pipe

6

237

1422

... More
250 mm dia Pipe

6

329

1974

... More
300 mm dia Pipe

4

351

1404

... More
350 mm dia Pipe

4

448

1792

... More
400 mm dia Pipe

2

518

1036

... More
All Types of D.I Ductile Iron (D.I) specials (viz. Bend, Tee, Taper, Tail piece etc), size conforming to IS specification No 9523/2000 With Cement mortar lining (inside) and bituminous coating (outside) (25% of payment will be held up till successful hydraulic testing) a) All socket Tee, 100 mm dia. to 300 mm. dia.

3773.4

128

482995.2

... More
350mm to 400mm dia.

1793.5

159

285166.5

... More
b) Double socketed bend 100 mm dia. to 300 mm. dia.

4714.6

125

589325

... More
350mm to 400mm dia.

1619.5

154

249403

... More
c)   Tail piece 100 mm dia. to 300 mm. dia.

1227.2

144

176716.8

... More
350mm to 400mm dia.

444.5

185

82232.5

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM² and body tested to 15kg/CM², flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. 100 mm dia

6

5067

30402

... More
150 mm dia

3

7487

22461

... More
200 mm dia

3

14769

44307

... More
250 mm dia

3

20429

61287

... More
300 mm dia

1

24205

24205

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut inside screw non- rising spindle type gunmetal/AISI 410 suitable for PN 1.0 rating complete with ball thrust bearing and enclosed gearbox (EN-8 with hardened by nitriding pinions of EN-19), flanges flat faced and drilled to IS.: 1538 : 1993. Valves tested by closed end method. 350 mm dia

1

94478

94478

... More
400 mm dia

2

105429

210858

... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified], i) 80 mm to 150 mm dia pipe

9

11990

107910

... More
ii) 200 mm dia pipe

3

15194

45582

... More
iii) 250 mm to350 mm dia pipe

5

18881

94405

... More
iv) 400 mm to450 mm dia pipe

2

22286

44572

... More
Construction of Thrust Block 300 mm dia Pipe

21

4952

103999.14

... More
350 mm dia Pipe

21

8045

168958.23

... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the with drawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC. (width cutting for trench as per IS 3114 : 2004 , P-1, Cl-3.2) 100 mm dia Pipe to 400 mm dia Pipe

528.06

1023

540205.38

... More
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick. (width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3) For 200 mm dia

13.41

939

12591.99

... More
Removal of rubbish, earth etc. From the working site and disposal of the same beyond the compound, in conformity with the Municipal/ Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer-In-Charge. Total = (pi()/4x OD^2 x L) + Road dismantling qnty.100 mm dia Pipe to 400 mm dia Pipe

541.47

166

89884.02

... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.

8684

-

3299.92

... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)

86.84

118

10247.12

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Taking Consideration for damage structure

2.44

5858

14294.81

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness and required bracing for concrete slabs, beams, column lintel curved or straight including fitting, fixing and striking out after completion of woks (upto roof of ground floor). (f) 25 mm to 30 mm shuttering without staging in foundation

19.54

205

4005.7

... More
Reinforcement for reinforced concrete work in all sorts of structure including distribution bars stirrups, binders etc initial straighting and removal losse rust if necessary cutting requiste length hooking and bending to correct shape placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (i) Tor steel/Mild Steel.Taking Consideration for Damage Structure

0.19

61751

11794.47

... More
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth

3.26

4919

16038.74

... More
Laying Cost of M.S pipe 100 mm dia Pipe

27.5

359

9872.5

... More
150 mm dia Pipe

15

564

8465.7

... More
200 mm dia Pipe

12.5

929

11619

... More
250 mm dia Pipe

15

1118

16773.45

... More
300 mm dia Pipe

7.5

1755

13163.1

... More
350 mm dia Pipe

7.5

2267

17005.35

... More
400 mm dia Pipe

2.5

2772

6932.3

... More
Add GST on 2 @ 18%

1

890676

890676.37

... More
Supply Cost of DI-K7 & M.S Pipe

-

-

-

... More
Supply & Delivery (at Site) of DI K-7 Pipes conforming to I.S-8329:2000. Included 18% GST 100 mm dia Pipe

2802.5

1287

3606817.5

... More
150 mm dia Pipe

1472

1858

2734976

... More
200 mm dia Pipe

1279.5

2367

3028576.5

... More
250 mm dia Pipe

1379

3118

4299722

... More
300 mm dia Pipe

701.5

3944

2766716

... More
350 mm dia Pipe

713.5

4809

3431221.5

... More
400 mm dia Pipe

248.5

5763

1432105.5

... More
Supply of M.S pipe Including Coating including 18% G.S.T 100 mm dia Pipe

27.5

1712

47083.85

... More
150 mm dia Pipe

15

2505

37577.85

... More
200 mm dia Pipe

12.5

3812

47657

... More
250 mm dia Pipe

15

4398

65977.5

... More
300 mm dia Pipe

7.5

5714

42858.68

... More
350 mm dia Pipe

7.5

6738

50540.85

... More
400 mm dia Pipe

2.5

7595

18989.95

... More
Add labour welfare cess on 2 and 3 @ 1%

1

274496

274496.99



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.