Municipal Affairs Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Municipal Affairs Department - MAD Tender
Civil And Construction
Building Construction
Water Storage And Supply
Eprocure
Opening Date27 Feb 2024
Closing Date7 Mar 2024
Tender Amount₹ 2,86,644
Costs
EMD
₹ 6,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAD_674610_20Bid Award Id
ViewTender No
MAD/ULB/BLGT/PW/30/23-24Tender Authority
Municipal Affairs Department ViewPurchaser Address
-Website
http://http://www.wburbanservices.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of Room for Drinking water including water purifier machines at different Wards within Balurghat Municipality
BOQ Items
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.( Payment to be made on the basis of measurement of finished quantity of work ) a) With earth obtained from excavation of foundationSOR, PWD, P-1, I- 3 a.
2.88
223
77.54
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
1.16
565
487.41
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. SOR, PWD, P-47, I-3
9.31
223
24
Cement concrete with graded Stone ballast (40 mm.) excluding shuttering.a) In ground floor and foundation.
6 : 3 : 1 proportion Pakur variety
0.74
4027
5442.18
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. Pakur variety
0.45
2520
5601.69
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).
[Note: - Waterproofing as per item 9, polymer based paint as
per item 8 (a) of subhead C of Section (C).
SOR, PWD, 3rd Corrigenda,P- 22, I-1
0.9
185
206
Brick work with 1st class bricks in cement mortar (6:1) a) In foundation and plinth
0.41
2017
4919.88
125mm thick brick work with 1st. class bricks in cement mortar (4:1). a) In ground floor
18.93
12765
674.33
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In Ground Floor
4.19
25589
6107.32
Reinforcements for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16G black annealed wire at every inter-section, complete as per drawing and direction.
0.41
23940
58250.5
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). (When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 12(e) for every 4 m. or part thereof.)
SOR, PWD, P-42, I-36
34.65
7103
205
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary . In ground floor. b) l, 15mm th.
46.17
6532
141.48
B)10mm th celling plaster (4:1)
7.2
910
126.48
Neat cement punning about 1.5mm thick in wall, dado, window, sills, floor, drain etc.
2.97
97
32.72
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing 10 kg/sq m to16 kg/m2
SOR, PWD, 3rd Corrigenda, P- 91, I-10
In Ground Floor
0.52
5230
10021
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.
Two Coats SOR, PWD P-196, I-10
In Ground Floor
18.67
1306
70
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats SOR, PWD P-196, I-8
In Ground Floor
21.68
977
45.1
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion Ground Floor SOR, PWD P-197, I-17
21.68
1452
67
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. SOR, PWD, P-200, I - 1
3.6
104
29
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss)-With any shade except white. b) On Steel surface Two Coats SOR, PWD, P-200, I - 2
3.6
284
79
Supplying, fitting and fixing UPVC down pipes A type and fittings conforming to IS 13592-1992 with necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete. i) UPVC Pipe 110 mm dia
4
1004
251
Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match withthe existing work & 4 nos. key stones (10mm) fixed with
adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if
required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. Corrigenda, P- 68, I -35
In Ground Floor
29.44
31206
1060
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength 1200 N SOR, PWD, Item No.-01, Page No. - 280
3.6
3261
906
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats
clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes a) For Exposed Work 20 MM DIA
3
429
143
32 MM DIA
3
849
283
(b) For Concealed Work 15 mm Dia
10
1400
140
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.). 20 MM DIA
1
657
657
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – Multilayer
) 1(a) 500 litre capacity
1
2584
2584
Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.
P.W.D. / S& P/ P-37/It. No-10
1
96
96
Labour for punching hole in plastic water storage tank upto 50 mm dia.
P.W.D. / S& P/ P-38 /It-13
4
76
19
Cutting hole through wall,roof or cornice and mending good all damages.
P.W.D. /S&P/P-97/It.-9
20
1360
68
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre.(i) 40 mm dia. boring etc. (49/1 )
27
2430
90
Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 40 mm dia. (51/4 )
2
586
293
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (i) 40 mm ( 102/1)
1
46
46
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).
(A) PVC Pipes (Dia) 40 mm ( 49/10 )
27
5589
207
COOLER MACHINE WITH HOT AND COLD SYSTEM (MARKET RATE) (80 lit Storage capacity)
1
80000
80000
Supplying, fitting and fixing pump (Crompton) (MARKET RATE )
1
11000
11000
Add GST @ 18%
1
43292
43292.45
Add cess @ 1%
1
2838
2838.06
Evaluation Notes How It Works ?
Potential Partner