Municipal Affairs Department Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Municipal Affairs Department - MAD Tender
Civil And Construction
Construction Material
Eprocure
Opening Date14 Jun 2024
Closing Date9 Jul 2024
Tender Amount₹ 4,89,98,784
Costs
EMD
₹ 2,50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MAD_693847_2Bid Award Id
ViewTender No
09 of SE(N)/MED/2023-24(2nd Call)Tender Authority
Municipal Affairs Department ViewPurchaser Address
-Website
http://http://www.wburbanservices.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
e)140 mm (OD)
5897
4806055
815
... More
f)160 mm(OD)
2352
2427264
1032
... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3, if contractor used water from deptt. source).
B) For UPVC/HDPE Pipe
c)110 mm (OD)
40362
152568
3.78
... More
d) 125mm(OD)
2983
11395
3.82
... More
e)140 mm (OD)
5897
25003
4.24
... More
f)160 mm(OD)
2352
11242
4.78
... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
B) For UPVC/HDPE Pipe
c)110 mm (OD)
40362
43590
1.08
... More
d) 125mm(OD)
2983
3698
1.24
... More
e)140 mm (OD)
5897
8491
1.44
... More
f)160 mm(OD)
2352
4068
1.73
... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC) 1% of Total Length on both Sides
1031.88
121761
118
... More
Bituminous pucca road (approx. 450mm depth) cutting by using gaiti, chisel, hammer etc. and picking uip the with drawing excavated materials and remove the same within distance of 30mtr. at least all complete for fixing/crossing all dia of pipe line as per direction of EIC.(width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3)
c)110 mm (OD)
424.08
433833
1023
... More
d) 125mm(OD)
125.52
128406
1023
... More
e)140 mm (OD)
343.6
351502
1023
... More
f)160 mm(OD)
136.48
139619
1023
... More
Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick.
(width cutting for trench as per IS 7634 (Part 2) : 2012 , Table-3)
c)110 mm (OD)
697.28
654745
939
... More
d) 125mm(OD)
62.16
58368
939
... More
e)140 mm (OD)
31.75
29813
939
... More
f)160 mm(OD)
25.81
24235
939
... More
Removal of rubbish,earth etc. from the working
site and disposal of the same beyond the
compound, in conformity with the Municipal /
Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Total = (pi()/4x d^2 x L) + Road dismantling qnty.
c)110 mm (OD)
1504.93
249818
166
... More
d) 125mm(OD)
224.29
37232
166
... More
e)140 mm (OD)
466.12
77375
166
... More
f)160 mm(OD)
209.58
34790
166
... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]
i) 80 mm to 150 mm dia pipe
103
1219005
11835
... More
Submission of complete detailed drawing of distribution system, rising main etc. after execution of work showing position of different types of valves, fittings/specials sluice valve chamber with location, node to node wise in the sanctioned drawing as completion drawing of the water supply scheme as per direction and satisfaction of EIC. The list of dia wise fitting/specials, different pipes ;of valve used in the rising main should be shown in the completion drawing (not separate) with verified by SAE & AE in-charge of the scheme. The above drawing will be submitted in 5 copies.
51594
19605
0.38
... More
Supplying and Laying of 300 mm dia (ID) M.S. Pipe conduits 20 m in length to be prepared from 8 mm thick M.S. plate by Horizontal directional drilling technique (H.D.D) Including supplying and laying of 160 mm dia Carrier ( HDPE ) Pipe within the conduit . Across and underneath the S.H. for Alipurduar Municipality area under AMRUT 2.0 Zone-III
1
324786
324786.11
... More
Supplying,laying, fitting, fixing and jointion of PVC-O (Oriebted Unplasticized Polyvinyl Chloride) pipes conforming to IS16647-2017 with latest revision and amendments, if any, with necessary DI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder, road sub-grade and its flanks but excluding moorum and laterite or sand stonehard and rock including cutting of brick payment without damaging the existing telephone/electrical cable line etc. (in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes specials valves carefully in trenches maintaining proper levels and alingment, jointing with integral homogeneous spigot, elastomeric sealing ring made of EPDM rubber including filling of excavated trench in all respect ( one per pipe) including cost of joiting materials etc complete in all respect (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with
-
-
-
... More
maintaining an average depth of cushion of 1.10 mtr. from top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C. N.B. i) Manufacturer's test certificate for PVC-O pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of PVC-O pipe & specials to be done by CIPET/SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii) No part payment at any stage on accont of supply of materials shall be entertained. iv) Payment will be made on actual consumption of materials. v) PVC-O pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi) Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill. if so
-
-
-
... More
vii) Any deviation from required clear cover of 1.10mtr. Due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. Viii) All pipe connection shall be completed in all respect and as per direction of EIC. Decision of EIC in this respect is final & binding. In case of any deviation / or any left out pipe connection an amount of Rs. 10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - 500, C-1.4, PN-12.5
-
-
-
... More
(A) Pressure Rating : Class - 500, C-1.4, PN-12.5
(iii) Laying of pipe line including cost of pipe, fittings/spe
cials & valves.
d) 250 mm(OD)
2637
6945858
2634
... More
Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3 , if contractor used water from deptt. source).
B) For UPVC/HDPE Pipe/PVC-O
d) 250 mm(OD)
2637
17905
6.79
... More
Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source).
B) For UPVC/HDPE Pipe/PVC-O
d) 250 mm(OD)
2637
9229
3.5
... More
Making barricading of excavation trenches of road width upto 15mtr. to avoid any accident by providing 75mm dia bamboo post placed vertically & horizontally with the help of 6”size iron rail as per direction and satisfaction of EIC. (Applicable where critical situation arise and take up the work as per direction of EIC)
3% of Total Length on both Sides
158
18644
118
... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. Total = (pi()/4x d^2 x L)
d) 250 mm(OD) Pipes
129.44
21487
166
... More
Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]
iii) 250 mm to 350 mm dia pipe
5
93180
18636
... More
Add GST @ 18.00%
1
7400386
7400386.91
... More
Add Cess @ 1.00%
1
485136
485136.47
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements