The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/replacement Of Ht Cables, Lt Ug Cables, Lt Panel, Transformers, Vcb And Allied Works At Af Stn Bagdogra Under Ge (af) Bagdogra. in Darjeeling, West Bengal, with an estimated contract value of Rs. 14,66,000. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 19-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date28 May 2025
Closing Date19 Jun 2025
Tender Amount₹ 14,66,000
Costs
EMD
₹ 29,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_710858_1Tender No
8653/BAG/2025-26/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing Surplus Soil to a distance not exc 50.00m away and depositing where directed at a level not exc 1.50m above the Starting Point, complete all as specified and directed.
35
-
-
... More
S&F Pre-cast PCC Cable Route Indicator of size 600x250x75mm including embossing 'DANGER/11KV CABLE/MES' on both sides and painted Letters with approved Colour, burried in ground for a depth of 35 cm including necessary Earth Work, complete all as specified and directed.
10
-
-
... More
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) up to 180mm thickness, or filling of clean dry coarse sand all-round the transformer platform/4Pole Structure and cable duct after cleaning grass/small bushes, etc. including removal of old dirty sand complete all as specified and directed. Note:- For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
20
-
-
... More
Suppl and laying un-reinforced precast concrete cable cover, class HV, type I with Flat size 300mm x 180mm x 40mm as protection of cable in trenches complete all as specified and directed.
100
-
-
... More
M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the existing surface with PCC 1:3:6 type C1 by (using 20 mm graded stone aggregate) 100mm thick complete all as specified and directed.
6
-
-
... More
M&L for 100mm dia bore galvanised iron light grade for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
6
-
-
... More
All as per above item No 8.00 but 80 mm dia complete all as specified and directed.
6
-
-
... More
All as per above item No 8.00 but 50 mm dia complete all as specified and directed.
6
-
-
... More
Taking down all electric connection to insulator, PG clamp ,jumpers (means tighed in nuts and bolts each accessories for smooth fuctions of HT supply) in 2/3/4/6 pole HT 11 KV structures, overhauling of GOD switch and DO fuse assembly on 2/3/4 pole HT 11 KV structures and including replacing fuse wire, binding wire, greasing after applying CRC, replacing worn out nuts/bolts, burnout jumbers, PG clamps and reconnecting all accessoris in existing position and greasing after applying CRC for smooth operation complete all as specified and directed.
4
-
-
... More
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, complete all as specified and directed.
10
-
-
... More
S&F Disc type insulator porcelain, vitreous,145mm high and 255mm dia ball and socket Type white , brown or green insulator single Disc Assembly for tension with Tension Clamps for conductors working pressure 11000 Volts, complete all as specified and directed.
10
-
-
... More
M&L Danger Notice Plate of 1.6mm thick Mild Steel Sheet, vitreous enamelled white, with Letters, Figures and Conventional Skull and Bones in Signal Red colour and fixed with MS Clamps Bolt and Nuts of approved size, for HT 25x20 Cm size including dismantling unserviceable one, complete all as specified and directed.
6
-
-
... More
S&F Expulsion Fuse, Single Pole, Channel type/drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuses, complete all as specified and directed.
2
-
-
... More
S&F Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 11000 Volts including dismantling of old unserviceable and connection to earth with GI 32x6mm Strip, complete all as specified and directed.
4
-
-
... More
S&F Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted on insulator and fitted on steel frame , current rating 400 Amps, mechanically operated mechanism from Ground Level consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including dismanting old unserviceable Switch Air Break of any description, complete all as specified and directed.
2
-
-
... More
Dismantling Air Break Gang Operated Switches HT 11 KV 3 Phase, any capacity ( 200/400 ) Amps vertical / horizontal mounted including Insulators and Operating Mechanism for repair/replacement of broken / worn out components and insulators etc. with or without taking down from Pole all as directed.
NOTE:- (a) Parts needed to be replaced shall be measured and paid seperately as 'supply only' against appropriate Items of Schedule. However Labour component involved in replacement is included in Unit Rate quoated against this Item. The Unit Rate shall deemed to be included for handling of serviceable materials for reuse to site and as directed
(b) Any minor repairs involved to make the GOD functional even if notified by Engineer-in-Charge shall be carried out by the Contractor without any extra cost to the Department.
4
-
-
... More
Supply only Male Contact/ Moving Contact Blade suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and directed.
4
-
-
... More
Supply only Female Contact/ Fix Contact Jaw suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and directed.
4
-
-
... More
Supply only Tinned Copper Flexible Jumper 200/400 Amps, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and directed.
4
-
-
... More
Supply only MS Jumper Carrier, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and directed
4
-
-
... More
Supply only Back Connector Plate, suitable for Air Break Gang Operated Switches, 11KV, complete all as specified and directed
4
-
-
... More
Supply & laying in replacement HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, conforming to IS:7098 (Part II), 11 KV, ‘Earthed Grade, with following cross-sectional area laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing, complete all as specified and directed.
Note:- Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
0.01
-
-
... More
95 sqmm, 3 core
20
-
-
... More
M&L Cable End Jointing Kit Indoor Termination Heat Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed.
1
-
-
... More
M&L Cable End Jointing Kit outdoor Termination Heat Shrinkable type complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 95 Sqmm complete all as specified and directed.
1
-
-
... More
M&L for Cable Jointing Kit for straight through Heat Shrinkable type joint complete with Jointing Materials with all Accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured Aluminium Conductor Cable of size 50 to 95 Sqmm complete all as specified and directed.
1
-
-
... More
Servicing to transformer at site of any capacity installed on Plinth/Pole mounted structure by opening top cover & replacing unserviceable spares/components of transformer ,without lifting core assembely reassembling after repair & testing complete all as specified and directed.
1
-
-
... More
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
2
-
-
... More
Supply only brass stud on LT side as per existing size, shape and specification for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
2
-
-
... More
Supply only cork sheet gasket (set of four) for ceramic bushing on LT side as per existing size, shape and specification complete for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
1
-
-
... More
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
3
-
-
... More
Supply only brass stud on HT side as per existing size, shape and specification for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
1
-
-
... More
Supply only top cover gasket set as per existing size, shape and specification complete for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
1
-
-
... More
Supply only breather assembly as per existing size, shape and specification complete for capacity 25 to 315 KVA, 11/0.433 Volts transformers complete all as specified and directed.
1
-
-
... More
Overhauling servicing of tap changer and replacement of unserviceable parts as ordered with new and assembling with old serviceable parts for smooth functioning and operation complete all as specified and directed.
1
-
-
... More
Dehydration and filtration of existing transformer oil of transformers capacity as mentioned below. 11/0.433 KV on site at different locations without disturbing the power supply system with filtration machine and heating system in order to achieve Di-electric strength of oil 60KV minimum at 2.5 mm gap complete all as specified and directed.
0.01
-
-
... More
25 KVA
1
-
-
... More
100 KVA
4
-
-
... More
250 KVA
1
-
-
... More
315 KVA
1
-
-
... More
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and directed.
Note:- Dielectric strength of oil should not be less than 60 KV when tested with 2.5 mm Gap electrode. complete all as specified and directed /cm complete all as specified and directed.
Make:- GULF/POWER OIL or equivalent as approved by GE
60
-
-
... More
Supply and replacing silica gel in crystal form of breather assembly of transformer capacity upto 400 KVA at installed site complete all as specified and directed.
0.25
-
-
... More
M&L for 25 mm dia gunmetal drain valve of transformer as per existing one complete all as specified and directed.
1
-
-
... More
M&L for 20 mm dia gunmetal drain valve of transformer as per existing one complete all as specified and directed.
1
-
-
... More
M&L for preparation of old painted steel or iron surfaces of transformer of 25 to 315 KVA, 11/0.433 Volts capacity transformers by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer with black synthetic enamel thick paint in white back ground complete all as specified and directed.
7
-
-
... More
M&L for Earthing complete with copper Earth Plate Electrode 600 x 600 x 3.15 mm, thick buried directly in ground (Earth pit not less than 2.25m deep below the Ground Level) with Top Edge of Earth Plate not less than 1.50m deep below normal ground level, connected to copper earth strip 20 x 3mm dia by means of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron 20 mm dia GI Pipe (Med grade) for watering, 40 mm dia GI Pipe light grade for protection of earth strip, including necessary earth work in any type of soil, PCC (1:3:6) Type C1 Concrrete pit of size 30cm x 30cm x 30cm and CI Cover plate fixed with hinges on suitable size angle complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and directed.
1
-
-
... More
Supply and fix Earth continuity conductor or Main Earthing lead fixed to wall or batten or reccess or chasses or buried in ground or drawn in conduit / pipe or fixed to Poles or any other indicated situation for loop copper strip of size 20mmx3mm connected to test point complete all as specified and directed.
6
-
-
... More
M&L for preparation of old painted surface of steel tubular pole of 9/11 mtr long for street/security lights, painting with one coat of aluminum paint on entire pole surface including (GI Brackets, clamps, Angle, Channel etc over one coat of red oxide paint and painting zebra pattern of alternate yellow and black strips with acrylic paint upto 0.9m height from pole coping and writing of pole Number in black paint on yellow background of dia 100mm dia, painting with one coat of waterproof cement based paint in white colour to pole coping complete all as directed by Engr-in-Charge. Note:- Shades of colour shall be used as per direction of Engineer-in-charge
30
-
-
... More
Disconnect and taking out the IDMT/ Numeric/ Microprocessor based relay of any type of any make from 11 KV HT panel at 11KV Sub Stn, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune / synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and directed.
Note:- The Contractor has to arrange necessary testing Kits, testing equipments, tools etc. Rental rates for the testing/ calibration kits & connected equipments & are deemed to be included in the quoted rates. Testing & tuning shall be carried out in the presence of representative of the accepting officer to the entire satisfaction of the rep of GE.
3
-
-
... More
Taking down HT switch gear (Vacuum circuit breaker ) at 11KV Sub Stn of capacity 12 KV, 400 Amps Make Crompton Greeves type 12VR18\800 comprising of repairs, complete overhauling / servicing, carrying out preventive maintenance alongwith testing of breakers by current injection test and refixing the same after repairs / overhauling:-
Note:-
(i) The servicing includes for busbar duct chamber, cable alleys and connecting accessories. (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, complete, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, busbar spout, busbar spout connections, circuit spout/circuit spout connections / buffer fixed contacts, moving contacts, tank assly / barriers, solenoid spares, dependent / spring mechanism / motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A', however the rate quoted shall be deemed to include for any other minor spares requiring replacement. (iv) The servicing shall be carried out by auhtorised service engineer of OEM and approval of the same shall be taken from Engr-in-Charge.
3
-
-
... More
Supply only the following spares suitable for 250 MVA to 450 MVA HT switch gear VCBs and 12 KV HT panel repair work under relevant Schedule:-
0.01
-
-
... More
CTs epoxy cast wound primary CTs with minimum primary current 50 to 100 A, double ratio, double core (Core 1:-2.5 VA, Class 0.5, ISF 2.5, and Core-2 15 VA, Class 5P10), STC:- 18.4 KA for 3 sec, Type:- BWP 6 BIL 12/28/75 Kvp.
Make:- Crompton Greaves or its equivalent all as per sample.
1
-
-
... More
S&F in replacement of CT housing for connacting to current transformer (CT) to VCB panel 3 phase, 3 limb indoor type including necessary connecting materials like busbar,nut, bolt complete all as specified and directed.
1
-
-
... More
Spring Charging Motor operating on 230 V DC having FL Watts 150, NLRPM 10, Rating 1 Min, Insin Class B type PMR5.
Make:- DELCO or its equivalent in ABB/CG
1
-
-
... More
Supply Only as in replacement voltage transformer (PT) 3 phase 3 limb indoor type primery voltage 11 KV and secondary voltage 110 voilts DC type VA class for HT VCB complete all as specified and directed.
1
-
-
... More
Shunt/trip coil 110 V DC
3
-
-
... More
Breaker control switch
1
-
-
... More
VCB Busbar Spout. Complete all as per Sample.
1
-
-
... More
VCB Circuit/Panel spout
1
-
-
... More
Control circuit HRC fuses 6 amp
3
-
-
... More
PT plug contact
1
-
-
... More
PT Spout Bushing
1
-
-
... More
Three Phase Energy meter, Digital type Class 1.0, 3 Phase. Suitable for mounting on existing HT Panel. Model EM6400 of Schneider Conzerv or its equivalent in L&T or ABB all as per sample.
1
-
-
... More
Single function meter, Digital type Voltmeter/Ammeter Class 1.0, 3 Phase. Suitable for mounting on existing HT Panel. Model WL132010oooo/WL1310100000
Make:- L&T / Schneider / HPL
1
-
-
... More
VCB buffers
1
-
-
... More
110 Volt DC closing coil/Trip Coil with assembly
2
-
-
... More
Push to trip knob red assembly
1
-
-
... More
Push to trip knob green assembly
1
-
-
... More
Ratchet wheel/handle
1
-
-
... More
Nylon release lever
1
-
-
... More
VCB charging powl
1
-
-
... More
Shutters for racking shaft
1
-
-
... More
Bus bar support insulator for VCB panel
1
-
-
... More
Vaccume Interrupter Bottle 12 KV, 50 HZ suitable for VCB 400 Amp.
Make:- Crompton greaves/Indoasia/C&S
1
-
-
... More
Rectifier/Power pack of rating as per sample complete all as specified and directed.
1
-
-
... More
Supply only in replacement of Thermostate for 11 KV VCB heating element with terparature range from 0-100 degree centigrade, 15A, 240/250 V, AC supply suitable for 400 Amp VCB complete all as specified and directed.
1
-
-
... More
Supply only Trip circuit supervision Relay suitable for working voltage 110 V DC and connecting the circuit with existing other relay Model XR 381 of make EASUN REYROLLE or its equivalent in Crompton greaves/ABB
1
-
-
... More
Supply Only Over Current Relay Current 1A/5A, IP 55 and connecting the circuit with existing other relay Model MIT 103 of make EASUN REYROLLE or its equivalent in Crompton greaves/ABB
1
-
-
... More
Supply Only Master trip relay suitable for working viltage 110/125 Volt DC and connecting the circuit with existing over current and earth fault relay complete all as specified and directed Model B24 of make EASUN REYROLLE or its equivalent in Crompton greaves/ABB
1
-
-
... More
Supply only space heater in HT VCB 11 KV with new one suitable to operate on 110 Volts DC supply complete with necessary wiring and control cable with toggle switch complete all as specified and directed.
3
-
-
... More
Supply only Indication Lamp (LED type) Set of 3 complete all as specified and directed.
Make:- L&T or its equivalent in Legrand/ ABB/ Siemens/ GE/ C&S Electric Ltd/ Schneider as approved by GE.
2
-
-
... More
M&L in replacement for filling of gravels of size 40 to 60mm all-round the transformer platform over sand filling complete all as specified and directed.
Note:- Sand filling shall be measured & paid separately here-in-before.
2
-
-
... More
Labour only for filling of old gravels of size 40 to 60mm all-round the transformer platform after taking out and cleaning the old gravels with water and removing the mud and external foreign partical complete all as specified and directed.
Note:- Sand filling shall be measured & paid separately here-in-before.
1
-
-
... More
M&L for structural steel work such as beams, angles, channels, flats etc., bent to shape and MS sheet for chamber / Trench covers including nuts, bolts and necessary Two Coat Black Paint on a Coat of Red Oxide painting including dismantling complete all as specified and directed.
70
-
-
... More
S&F HDPE double wall Corrugated Duct Pipe of Size 40 mm OD and 32 mm ID for Cable Protection laid in trench complete all as specified and directed.
100
-
-
... More
Supply and laying well burnt/Fly ash brick of size 200x100x80mm locallly available as protection of cable in trenches complete all as specifed and as directed by Engineer in charge
1500
-
-
... More
M&L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 x 600 x 6mm, thick buried directly in ground ( earth pit not less than 2.25m deep below the Ground Level) with Top Edge of Earth Plate not less than 1.50m deep below normal ground level, connected to Galvanised steel iron earth strip 32x6mm dia by means of Bolts, Nuts, Check Nuts and Washers made of Galvanised Iron 20 mm dia GI Pipe (Med grade) for watering, 40mm dia GI Pipe light grade for protection of earth lead wire, including necessary earth work in any type of soil, PCC (1:3:6), Type C-1 Concrrete pit RCC (1:1.5:3) Type A-1 Precast cover (54x54x5Cm) duly reinforced with including 8mm Dia TMT Bar @ 150 mm c/c both ways lifting handle made of 8mm dia TMT Bar embeded in precast cover slab complete as shown in electrical Plate No 3 of SSR Part-I including testing on completion complete all as specified and directed.
1
-
-
... More
Taking up/down existing defective cable of sizes 2/3/3.5/4 core 10 to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station complete all as specified and directed.
660
-
-
... More
All as per above item No. 53 but 95 to 300 sqmm complete all as specified and directed.
120
-
-
... More
Laying, jointing, testing and commissioning of serviceable cable obtained from taking out in same or new location or position i.e. in trenches /on walls /floor /roof /ceiling etc of size 2/3/3.5/4 core 16 to 70 sqmm including necessary cable lugs, gland etc complete all as specified and directed.
90
-
-
... More
Supply & laying testing and commissioning in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated PVC FRLSH, armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes including cable lugs, glands, insulation tape etc complete all as specified and directed.
0.01
-
-
... More
10 sqmm 4 core
80
-
-
... More
16 sqmm 2 core
100
-
-
... More
16 sqmm 4 core
100
-
-
... More
25 sqmm 4 core
90
-
-
... More
35 sqmm 4 core
80
-
-
... More
50 sqmm 3.5 core
70
-
-
... More
70 sqmm 3.5 core
50
-
-
... More
95 sqmm 3.5 core
30
-
-
... More
120 sqmm 3.5 core
30
-
-
... More
185 sqmm 3.5 core
30
-
-
... More
240 sqmm 3.5 core
30
-
-
... More
400 Sqmm 3.5 Core
30
-
-
... More
M&L for straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10/16sqmm x 4 core cables including testing complete all as specified and directed. Make:- Densons / 3M / Raychem
0.01
-
-
... More
10-16 sqmm 3/3.5/4 core
1
-
-
... More
25-50 sqmm 3/3.5/4 core
1
-
-
... More
70-120 sqmm 3/3.5/4 core
1
-
-
... More
150-185 sqmm 3/3.5/4 core
1
-
-
... More
240-300 sqmm 3/3.5/4 core
1
-
-
... More
S&F in replacement MCCB of 50 Hz,415 V adjustable type complete all as specified and directed of following sizes.
0.01
-
-
... More
630 Amp, 4 pole, 36 KA Cat part no CM94106OOS1OG model DN3-630D of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
400 Amp,4 pole, 36 KA Cat part no CM94106OOS1OG model DN3-630D of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
250 Amps,4 Pole, 36 KA Cat part no CM98065OOPO model DU250 of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
200 Amps, 4 pole, 36 KA Cat part no CM98065OONO model DU250 of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
160 Amps, 4 pole, 36 KA Cat part no CM98065OOMO model DU250 of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
125 Amps, 4 pole, 25 KA Cat part no CM90634OONO model DU250C of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
100 Amps, 4 pole, 18 KA Cat part no CM90677OOLO model DU125D of L&T or its equivalent in Seimens/ Legrand
1
-
-
... More
63 Amps, 4 pole, 18 KA, Cat part no CM90518OOJO model DU100D of L&T or its equivalent in Seimens/ Legrand
2
-
-
... More
S&F in replacement Onload Change over switch, I-O-II Operation, manual type, with sheet steel enclosure. complete all as specified and directed for following Capacity
0.01
-
-
... More
250 Amps,4 Pole type CO3-250 of L&T or its equivalent in Seimens/ Legrand/ABB
1
-
-
... More
Supply and replace aluminium lugs suitable for LT UG XLPE aluminium conductor cable including nuts,bolts,washers and PVC tape. complete all as specified and as direcred for following sizes.
0.01
-
-
... More
400 Sqmm LT UG XLPE aluminium conductor cable
10
-
-
... More
300 Sqmm LT UG XLPE aluminium conductor cable
10
-
-
... More
240 Sqmm LT UG XLPE aluminium conductor cable
10
-
-
... More
185 sqmm LT UG XLPE aluminium conductor cable
10
-
-
... More
120 sqmm LT UG XLPE aluminium conductor cable
18
-
-
... More
95 sqmm LT UG XLPE aluminium conductor cable
18
-
-
... More
70 sqmm LT UG XLPE aluminium conductor cable
24
-
-
... More
50 sqmm LT UG XLPE aluminium conductor cable
36
-
-
... More
25 sqmm LT UG XLPE aluminium conductor cable.
36
-
-
... More
16 sqmm LT UG XLPE aluminium conductor cable.
40
-
-
... More
10 sqmm LT UG XLPE aluminium conductor cable.
40
-
-
... More
M&L for servicing of LT panels/Feeder piller box of any size by complete cleaning of panel and bus bar at chamber with CTC solution, and welding the door using arc welding and fixing of hinges/Locking Handles/latches and necessary nut, bolts, washers and made it completely functional for open/close and incl checking of incoming and out going cable connections, Re-fixing of existing Cables, ACBs & MCCBs, and repair to connected PCC foundation and frame works, rewiring of control and power wiring of LT panel/Feeder with suitable size of FRLS cable but not less than 1.5 sqmm, replaceing of various unserviciable ON/OFF switches, lugs/Gland/Base plate/indicating Lamp/CT Coil etc making the panel fully functional including numbering the LT panel/feeder box and marking on panels (incoming and locations of outgoing MCCBs), to the satisfaction of Engr-in-Charge complete all as specified and directed Note:- Cost is inclusive of minor parts such as lugs, gland,nuts, bolts, washers, locking handle, latches, ON/OFF switches, Base Plate but Excluding Ammeter, Voltmeter, CT Coil, Indicating Lamp.
10
-
-
... More
M&L for painting of LT panel by spraying two coats of epoxy based weather proof paint of colour as directed over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and directed.
40
-
-
... More
S&F Indication Lamp (LED type) Set of 3 Complete all as specified and directed by Engr in-Charge.
Make:- L&T or its equivalent in Legrand/ ABB/ Siemens/ GE/ C&S Electric Ltd/ Schneider as approved by GE.
3
-
-
... More
Supply and replacement of three phase digital type Ammeter 0-400 Amps, class 0.5 with selector switch complete all as directed Cat Part No WL131020OOOO of Make L&T or its equivalent in Schneider or ABB
3
-
-
... More
Supply and replacement of three phase digital type Voltmeter 0-500 Volts, class 0.5 with inbuilt selector switch complete all as directed Cat Part No WL132020OOOO of Make L&T or its equivalent in Schneider or ABB
3
-
-
... More
S&F replacement resin cast wound /ring type CT 100/400 /5A class 1.0 433 Volt for fixing in LT panel board complete all as specified and directed.
Make:- AE / IMP / MECO / MEI / HPL
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%