Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Work Services For Augmentation Of Power Supply For Induction Of Iaccs At Salua Under Ge Af Kalaikunda in West Midnapore, West Bengal, with an estimated contract value of Rs. 5,98,49,100. The bid opening date for this tender is 28-10-2021 and the last date for bid submission is 26-11-2021. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date28 Oct 2021
Closing Date26 Nov 2021
Tender Amount₹ 5,98,49,100 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing of Glow Sign Board of size 4 mtr x .75mtr of with proper LED lighting arrangement for 33/11 KV main receiving station with complete acessories all as specified and directed

1

-

-

... More
All as per Item No. 45.00 here-in-before but CO2 Type 4.5 kg capacity

2

-

-

... More
SCHEDULE "A" PART- X (LIGHTNING CONDUCTOR) Details of prepriced Schedule is given in tender documents

1

-

-

... More
Serial Item No. 17.00 Contd... 3. The VCB Panel shall have the following relays (i) Three phase over current digital numeric relay (Instantaneous and Inverse time phase over current protection (50/51), Instantaneous and Inverse time Earth fault protection(51/51N), Instantaneous and Inverse time phase under voltage protection(27), Thermal Overload Protection(49), Under Current Protection(37), Phase unbalance Protection(46) with IEC103 (ii) Master trip relay (86) (iii) Auxiliary relay (iv) Trip circuit supervision relay (95)" " Note for VCB PANEL : (i) The VCB PANEL shall be installed by service engineer from the company only including making necessary arrangement for connection of cable. (ii) Contractor shall make all arrangement on site for testing of tripping mechanisam / setting of relay functionality of VCB on short circut / earth fault / over voltage / over current etc. All testing equipments required for trip test shall be arranged by contractor. Tripping test of VCB on earth fault, over current and over voltage to be carried out by contracot before completion of work to the entire satisfaction of MES and user Rep. Same testing arrangement to be done at the time of precommisioning test of SEI. Cost of the same is deemed to be included in unit rate of item. All required calabration to be done by contractor. (iii) Contractor shall submit general arrangement of VCB panel and get approval of drawing and make of VCB before placing the order for procurement. (iv) VCB Panel shall be dispatch at work site only after carrying out factory test at OEM permises in presence of MES Rep as per relevant IS and tests mentioned in PS ."

-

-

-

... More
M&L for cutting the existing GI/CI pipe line of size 150/100 mm dia bore and making provision for connecting / insertion of GI pipe of 80/25 mm bore for out let / branch line including all acessories like tee etc including necessary excavation and earth work, returing refilling , removal etc complete all as specified and directed by Engineer in Charge.

2

-

-

... More
Supply, Installation, testing and commissioning battery bank floor mounting type input 415 volts AC 50 % alongwith volt meter Amp meter and respective selector switches toggle switches, indicator and terminals block suitable for 110 volts DC 150 AH lead acid type battery for DC tripping for two Nos remote Control panel of 33/11 KV transformer control pannel and VCBs - 02 Nos with necessary wiring and comprising of the following accessories:- (one working +one stand by) (a) (i) Battery Bank, type 2 Volt per cell 150 AH including filling of acid/electrolite, provn of stand and connection - 55 Nos (ii) Standard accessories ( as per manufacture catalogue) (b) Automatic float (40 amps ) & boost (18 amps) battery charging equipment suitable for 110 volt 150 AH lead acid battery bank - 01 set.

1

-

-

... More
Supply only 33 KV insulation Gloves for 33/11 KV main receiving station all as specified and directed

2

-

-

... More
SCHEDULE "A" PART -XI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES.

-

-

-

... More
S & F and jointing , testing PVC insulated, sheathed, LT, 1100 volt grade, ISI marked copper coundutor multi stranded wire of size 2.5 sqmm x 3 core for street light connection complete all as specified and directed.

200

-

-

... More
Supply, Installation and commissioning 33 KV , 50 Hz oil limmersed Potential transformer for metering and protection single phase outdoor type mounted on fabricated steel structure and fixing bolts, nuts check washer etc of ratio 33 KV/V3/110V/V3 volts, rated burden 50 VA, accuracy class 3P as per IS:3156 for protection inclluding first filling of transformer/insulation oil conforming to IS : 335 and dielectric strength 40 KV as per IS 1866 complete with all accessories and including connection all specified and directed.

2

-

-

... More
Supply, laying, joniting, testing and comissioning PVC insulated sheathed & armoured heavy duty control cable with stranded copper conductor of size 2.5 sqmm x 10 Core of 1100 volt grade, including copper lugs complete all as specified.

500

-

-

... More
Supply, jointing & testing complete Jointing kit for 33 KV grade for outdoor terminatation cold shrink type joint complete with jointing material and accessories suitable for XLPE armoured cable of size 95 Sqmm x 3 Core cable complete all as specified and directed by Engineer in Charge.

1

-

-

... More
Supply of Cease fire ABC Fire Extinguisher portable type of 2 KG capacity

4

-

-

... More
Supply, installation, testing and commissioning battery bank with charger for 30 V DC system having 100 AH battery bank and 20 A charging system complete all as specified and directed. Note for Serial Item Nos. 15.00 to 35.00:- All the items shall be as per relevant IS with latesh amendments unless otherwise specified.

5

-

-

... More
Supply, fixing, grouting and painting cable route indicator made up of Factory made Precast RCC slab of size 100 cm x 40 cm x 80 mm thick duly embossed with "MES HT Cable" / "MES LT Cable",Size of Cable and grouting on the route of HT/LT cable complete. Note :- (i) Unit rate of item includes excavation, PCC foundation for erection of route indicator. (ii) Slab of route indicate to be provided with min 4 Nos x 8 mm diameters TMT bars along length of slab with 7 Nos cross bar 6 mm dia in reinforcement with shuttering. (iii) Route indicator RCC slab to painting with two coat of red colour synthetic enamel paint over on one coat of white primer base all as specified and directed by Engr - in - Charge.

160

-

-

... More
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
Supply jointing & testing complete Jointing kit for 33 KV grade for indoor terminatation cold shrink type joint complete with jointing material and acessories suitable for XLPE armoured cable of size 95 Sqmm x 3 Core cable complete all as specified and directed by Engineer in Charge.

1

-

-

... More
Supply,Installation , testing and commissioning of 33/0.433 KV Distribution station transformer of capacity 63 KVA , 3 Phase, 50 Hz, Conf to IS 1180: 2014, Level- 2 , outdoor type, plinth mounted, step down transformer, Onan cooled, oil immersed, copper wound, with vector group DYN 11 , complete with first filling of IS 335 , ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories / mountings conforming to relevant IS and 7 position tap changer (Tapping range +5% to -10% in step of 2.5% each complete all as directed . Note for Transformer under serial item 15.00 & 16.00 above: (i) Power transformer and distribution transformer to be placed on PCC plateform and its Bi directional roller to be locked properly (ii) The contractor shall furnish original bill certificate (purchase voucher) test certificate, and warranty certificate of the transformer from manufacturer. (iii) The contractor shall submit the general arrangement darwing of transformers and get the approval of GE for Make and darwing of transformers before placing the order. (ivi) Prior to manufacturing the general arrangement drawing, design and details of transformer shall submitted to GE for approval. (v) Both Transformers shall be dispatched only after inspection at manufacture premises to be done by OEM Auth & MES Auth at manufacture premises Routine test as per IS relevant IS to be carried out at Factory in presence of MES rep. (vi) Connection of Transformer WTI to VCB through multi core copper conductor control cable of suitable size (irrespective of length) is deemed to be included in the item. (viii) Contactor shall submit the operating manual and maintenance schedule of transformers from OEM in two sets.

1

-

-

... More
Supply and fixing of notice /Drawing board and safety instruction chart of with LED lighting arrangement of suitable size for 33/11 KV main receiving station with complete acessories all as specified and directed.

1

-

-

... More
S&F Fire shield brand modular ABC store pressure type fire extingusher 9 Kg capacity made of MS body treated against corrosion fitted with clamps arrangement and fixing in front / side of HT VCB of 33 KV Sub Station including testing complete all as directed.

2

-

-

... More
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts, indoor type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 2.0 mm thick CRCA sheet l, with angle iron fra me of 40 x 40 x 6 mm , ofully compartment of minium size 1.2 mtr (L) x 1.50 mtr (H) x 0.50 mtr (D), , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-43 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 200 Amps pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel all as specified with supply and fixing the following. (A) Incoming: (i) MCCB 100 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 80-100 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 KA --- 01 Nos with rotatary handle . (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No. with Suitable CT and wiring. (iii) Three indication lamp Neon type for three phase. (ivf) Change Oover Switch 125 Amps, 4 Pole, 415 V, 50 Hz , " ON LOAD" type - 01 No (B) Out going : (i) MCCB 63 Amps rating, 4 pole ,415 V, AC, 50 HZ, thermal release range 100-125 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 KA --- Qty : 02 Nos with rotatary handle . (ii) MCB SPN 32 Amp . 220 V, 50 Hz, 10 KA , C Curve - Qty : 02 Nos (ii) MCB SPN 16 Amp . 220 V, 50 Hz, 10 KA , C Curve - Qty : 02 Nos

1

-

-

... More
Supply, installed, testing and commissioning of 33 KV 200 Amp, Polymeric Tilting type Vertical GOAB with 3 Post Insulators of 34mm FRP , square rod and handle but without GI Pipe . ( 1 set = 3 nos. ) complete all as specified and directed.

4

-

-

... More
SCHEDULE "A" PART- IX (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents

1

-

-

-

-

-

... More
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents

1

-

-

... More
Supply only 33 KV Discharge rod for 33 KV sub station all as specified and directed

2

-

-

... More
M&L for on site construction RCC hume Pipe septic tank for 10 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as shown in drawing and all as specified.

1

-

-

... More
M&L street light / security light bracket (suitable for street light fittings in poles) upto 1.5 RM , make out of GI pipe of light grade, ISI marked Conf to IS 1239 of 40mm dia proper shaped, bend, threaded and drilling holes for wire entry and MS clamps (02 Nos) of suitable size of flat iron of 40 mm x 5 mm inproper shape and sized including MS nut bolt and washer for fixing bracket and clamp on pole including painting of bracket and clamp with two coat of aluminium paint over red oxide primer all as specified and directed by Engr-in -charge.

16

-

-

... More
Supply of Fire Bucket set of 2 Nos of 15 Lts capacity including stand

1

-

-

... More
SEWAGE DISPOSAL M&L for 150 mm dia RCC NP3 pipes laid on 150mm thick PCC 1:4:8 bed with excavation in any type of soil, including manholes/drop manholes of standard size made of Brick masonry/RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewere line functional.

50

-

-

... More
SCHEDULE "A" PART- VI (COMPOUND WALL, FENCING & GATE) Details of prepriced Schedule is given in tender documents

1

-

-

... More
INTERNAL ELECTRIFICATION. M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earth wire of size 4 mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 15 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed.

2

-

-

... More
EXTERNAL ELECTRIC SUPPLY Supply,Installation , testing and commissioning of 33/11 KV, 3 Phase, 50 HZ, Power transformer of capacity 2500 KVA , outdoor type, plinth mounted, step down transformer, ONAN cooled, oil immersed, copper wound transformer complete with first filling of IS 335 , ISI marked filtered & dehydrated transformer oil and other standard fittings / accessories, 17 position ON Load Tap changer (OLTC) with tapping range +5% to -15% in steps of 1.25% each, with Remote tap cubical changer (RTCC) panel & Automatic voltage regulator (AVR) with Vector group Dyn-11 conforming to IS: 2026 and complete accessories including HV Bare Bushing, LV Bare Bushing, Buchholz Relay (having Contacts for Alarm & Trip), OTI (having Contacts for Alarm & Trip), WTI (having Contacts for Alarm & Trip), Marshalling Box including cable end box on both incoming and out going side complete all as specified and directed.

2

-

-

... More
Supply, Laying, jointing and testing cable XLPE insulated screened PVC badded galvanised steel strip of wire armoured electric power cables (heavy duty) with standed aluminium coductor ,11 000 volt grade , 3C X 95 sqmm laid in trenches/ duct complete all as specified and directed.

8080

-

-

... More
Supply, fixing and testing cast iron sluice valve 80 mm dia, both side flanged, class 1.0 PN, long body, ISI marked, conf to IS-14846 with valid CML No. / Batch No., Manufacturer Sl No.etc, with brass spindle and check nut, CI hand wheel including fixing the valve by providing nut bolts, washers, rubber gasket and MS flange complete all as specified and directed by Engr-in -charge. Note : Contractor has to submit the Purchase voucher and Manufacture test certificate of Sluice valve .

2

-

-

... More
M & L Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.18 mm thick, buried directly in ground in earth pit diggiged in any type of soil (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to coper strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. Note : (i) GI strip of 32 x 6 mm upto 7.5m including, protection pipe and testing is deemed included in the item. (ii) Display plate made of MS sheet of size 300 mm x 200 mm x 3 mm welded to MS square bar to be fixed by contractor on each earthing without any extra cost. (iii) Contractor has to fill up the remaining poertion of earth pit after placing electrode and salt & charcoal with low resistivity agriculture soil to be bring from out side defence land without any extra cost.

97

-

-

... More
Supply, Install, testing and commissioning of emergency battery backup system (Invertor) of capacity 3.5 KVA inclusive of Tubular battery 180 AH, 24 volt system , 4 Nos necessary wiring with PVC heavy duty 25mm dia conduit saddle on wall/roof from invertor to main distribution box for output supply of 220 volt all as directed and specified.

1

-

-

... More
M& L for preforted type cable tray made of 1.5 mm GI sheet 30 cm wide suitable for holding control cable complete all as specified and directed .

300

-

-

... More
SCHEDULE "A" PART- VII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents

1

-

-

... More
Supply and fixing pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut , 266 mm height and 240 mm dia for 33 KV grade complete all as specified and directed.

27

-

-

... More
S&F ISI marked Insulating mat as per IS 15652 (2006) made of dielectric ' elastomer' ISI marked with test certificate of 1 m X 10 m X 2.5 mm, class B, working voltage 11 KV, Di-electric Strength 45KV , one side plain and other side anti skid heat proof, Acid , alkali and transformer oil proof marked with IS number, class batch number and brand name at every meter of mat, blue colour complete all as specified.

40

-

-

... More
Materials and labour for hot dip galvanised steel structure work for making structure to mount electrical equipment fabricated from galvanised structural steel such as channel angle iron flat iron etc plate and bolts nuts and washers welding bending cold or hot drilling holes for bolts in proper shape of size including fixing on RCC pillar/plate form with foundation bolts nuts check nuts washers all as shown on drawing complete all as specified and directed.

150

-

-

... More
COMPOUND WALL, FENCING & GATE S&F punched tape concertina coil 610 mm dia using high tensile spring steel wire of 2.60mm dia as per IS-4454 and steel tape in 19 mm width as per IS- 513 and including 18 micron zinc coating. (Each coil is to be expanded up to max of 6.00 mtr length) complete all as specified and directed.

375

-

-

... More
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced Schedule is given in tender documents

1

-

-

... More
Supply, laying, joniting, testing and comissioning PVC insulated sheathed & armoured heavy duty control cable with stranded copper conductor of size 2.5 sqmm x 8 Core of 1100 volt grade, including copper lugs complete all as specified.

500

-

-

... More
Supply fixing and comissioning wall mounted voltage stabilizer for automatic operation, single phase, AC, 50 Hz, copper wound transformer, having digital display, naturally air cooled indoor type and designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of ± 2.5% of capacity 1.0 KVA complete all as specified and directed by Engineer in Charge.

1

-

-

... More
Supply of Fire hook

2

-

-

... More
Supply & Laying testing and commissioning 33 KV (earthed) HT cable , XLPE insulated screened PVC badded galvanised steel strip of wire armoured electric power cables (heavy duty) with standed aluminium coductor 33000 volt grade , 3C X 95 sqmm complete all as specified and directed by Engineer in Charge.

60

-

-

... More
Supply,Install, testing and commissioning HT 11 KV, 3 Phase 50 HZ,630 Amps,350 MVA Vaccum Circuit Breaker Panel factory made, Indoor type horizontal drawout and horizontal /vertical solation, metal clad copper bus bar including necessary cable termination and connection for incoming and outgoing cables as required and comprising of the following complete as per IS -13118 and IEC-56 at as specified including necessary connection with auxillary DC 110 volts supply from battery bank to relays complete all specified and as directed and comprising the following :- (Loc of installation : At 33/11 KV Sub Stn in Aalpha area) (a) HT VCB for Incoming Supply - 02 Nos (b) HT VCB for Out Going Supply - 06 Nos (02 for existing 11 KV Sub Stn + 02 Nos for under ground Ops Room + 01 No for 11 KV Capacitor bank + 01No Spare) (c) HT 11 KV Bus Coupler - 01 Nos " 1. VCB panel shall have the following accessories as per manufacturers design:- (i) Local remote selector switch - 01 Nos (ii) Push Button for trip circuit healthy check. (iii) LED indicating lamp - 1 set (iv) MCB for AC & DC - 01 Set (v) Hooter with single window annuciator - 01 No (vi) Control transformer (110VAC to 110 VDC) vii) Power pack (110V DC) - 01 No (viii) Panel space heater with thermostat & switch (ix) Panel illumination lamp with switch (x) Side cable box (xi) Suitable CTs for all feeders (xii) Suitable PT for income. 2. VCB panel shall have the following metering equipments (i) Digital Ammeter with selector switch (ii) Digital Voltmeter with selector switch (iii) Three phase trivector HTCT meter of class . Contd.....

1

-

-

... More
SCHEDULE "A" PART- V ( ROAD/PATH AND CULVERT) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
INTERNAL WATER SUPPLY Supply and fix 15 mm dia angular stop cock chromium plated high pressure with long shank and cup capstan headed screwed down complete all as specified and directed.

3

-

-

... More
Supply only Gum Boots, ISI marked, confirming to IS of size 9 No. for 33/11 KV sub station all as specified and directed

2

-

-

... More
Supply of Fire Beater suitable of size

2

-

-

... More
EXTERNAL WATER SUPPLY Construction of brick work Valve chamber with inner dimensions of 900 mm x 900 mm x 900 mm with PCC (1:4:8) type D-2 in foundation 23mm thick brick work in CM (1:4), (PCC 1:2:4 type B-1 in coping, rendering 15 cm thick both internal and external surface in CM 1:4 including provn of MS sheet cover of 3mm thick with MS angle frame work of angle size not less than 40 x 40 x 6 mm all as shown in TD drg, painted with two coats of synthetic enameled paint over a coat of red oxide primer and locking arrangement including necessary earth work and excavation in any type of soil complete all as specified and shown in TD drg.

4

-

-

... More
Supply, fixing connecting hollow alluminium bus pipe of 40 mm nominal size as per IPS 40 mm for 33 KV operating voltage and of 200 Amp including clamps/connectors/extener etc with electrical equipment/distribution system by means of bolts, nuts, washer clamps and testing including colour coding for three phase R YB complete all as specified and directed.

450

-

-

... More
Supply, install, testing and commissioning single pole Lightining arrestor of rated 33 KV for gapless metal oxide type discharge current 10 KA , class II, pressure relief A/40 KA surge counter with leakage current, station class with all accessories and including necessary connection as per IS : 3070 Part II and IEC 99-A1991 complete all as specified and directed.

3

-

-

... More
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.

1

-

-

... More
M&L for construction Soakage wells of size 1.8 M dia X 3.0 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as shown in drawing and all as specified.

2

-

-

... More
Supply, fixing and testing cast iron double orifice Kinetic Air Release valve 80mm dia with two air outlets of 50 mm dia bore, both end flanged and including fixing the valve with pipe by providing nut bolts, washers, rubber gasket and MS flange complete all as specified and directed by Engr-in -charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.