Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair / Maint Of Ro Plant , Cleaning Of Oh Tanks And Connected Works At Raspunja Mil Camp, Od Alipur, Sahapur Mil Camp And Hastings Area Under Ge (central) Kolkata in Kolkata, West Bengal, with an estimated contract value of Rs. 29,48,000. The bid opening date for this tender is 03-06-2023 and the last date for bid submission is 06-07-2023. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date3 Jun 2023
Closing Date6 Jul 2023
Tender Amount₹ 29,48,000
Costs
EMD
₹ 58,960Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_600981_1Bid Award Id
ViewTender No
8601/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only discharge valve for decrine dosing pump including taking down unserviceable one complete all as specified and directed.
2
-
-
... More
S&F reverse osmosis UV light cap 250 LPH including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
4
-
-
... More
Supply & loading of cation resin after taking down old unserviceable one in the existing softening plant complete all as directed.
2550
-
-
... More
S&F flow meter of RO plant up to capacity of 1000 LPH including taking down of old unsv one complete all as specified and as directed by Engr-in-charge.
4
-
-
... More
S&F reverse osmosis UV light cap 500 LPH including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
4
-
-
... More
All as per item No 01 here-in- before but service tank 500 Ltr capacity
10
-
-
... More
Supply and replacing MNO2 inside oxidation chamber at different location including taking out old one complete all as directed.
2.8
-
-
... More
Supply only Gravel 1/4" to 1/10"
4.5
-
-
... More
Supply only foot valve assembly suitable for decrine dosing pump including taking down unserviceable valve complete all as specified and directed.
3
-
-
... More
Supply only Coarse sand for filter media (16/32) mesh size
7.5
-
-
... More
M&L for painting with one coat of black bituminous paint suitable for drinking water inside the vessels complete all as directed by Engr-in-Charge.
130
-
-
... More
Supply only Gravel 3/4" to 1"
3.8
-
-
... More
Opening top cover by unscrewing the bolts of 10,000 GPH softening plant, unloading the cation resin from upper portion of softening plant, keeping the resin bed at stable condition at triangular park complete all as specified and directed. Note : (i) Chemical analysis Lab test : (1. Hardness 2. Iron 3. PH 4. Silica ) of Softener Plant treated water from virious area from Govt. approved laboratory including collection of water , sterillized bottle for testing and submission of the test report (ii) testing is to be carried out on each plant and once in every qtr is inclusive of coated rate)
4
-
-
... More
S&F heavy duty PVC pipe of suitable size to with stand 5KG/Cm 2 pressure suitable for decrine dozing pump to rising mains including taking out existing unserviceable one complete all as specified and directed.
60
-
-
... More
S&F reverse osmosis UV light cap 1000 LPH including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
4
-
-
... More
Taking out of pump from existing position dismantling and repairing of pressure pump of any type up to 0.5 hp capacity rewinding the same with super enamelled copper winding wire as per existing gauge and turn to achieve required RPM, replacement of ball bearing, bush, impeller, connection wire, cooling fan of motor, oiling etc including testing complte all as specified and as directed.
6
-
-
... More
Supply only ring seal valve for Decrine dosing Pump including taking down unserviceable onecomplete all as specified and directed.
3
-
-
... More
M&L for overhauling of RO plant of capacity 400/600/1000/2000 LPH opening the pump set from RO, dismantling the parts for inspection, replacement of all u/s parts i.e bushes bearing impellers, rewinding of 2/3 HP, 3 phase motor winding and replacement of viltroli coupling shaft seal complete to build up the pressure for smooth functioning of RO plant complete all as specified and directed by Engr-in-Charge. Note : (i) Chemical analysis Lab test : (1. TDS 2. PH 3. Micro biology (ecoly / coliform count) 4. Silica 5. Iron) of RO Plant treated water of various area from Govt. approved laboratory including collection of water in sterillized bottle for testing and submission of the test report
(ii) Testing is to be carried out on each plant and once in every qtr
6
-
-
... More
S&F in repair micron catridge capacity 20" slim complete all as specified and direted by Engineer-in-Charge.
20
-
-
... More
Supply only common salt for controlling of hardness of water of approved quality at water treatment plant complete all as directed.
Note : Transportation charges of qty as required to water treatment plant located at Hasting area will be included in the item rate.
1750
-
-
... More
M&L for repairing of TDS meter of RO plant capcity 1000/2000 LPH display flow rate incl TDS, pH etc from oem complete all as specified and as directed by Engr-in-charge.
3
-
-
... More
Opening top of 10,000 GPH capacity iron removal plant pressure filter, vertical type, unloading the filter media from the pressure filter e.g sand gravels (different sizes), taking out carefully strainer (Push/Thread) from inside bed plate, cleaning the inside bed plate & strainer fixing holes on the bed plate, disposal of sand within 100 metre radius from the existing filter plant, segregate the different sizes of old gravels washing the serviceable gravels by 3% strength HCL, clean the gravels by clear water to remove iron scales on the old gravels cleaning the PVC old serviceable strainer by concentrated hydrochloric acid complete all as directed by Engineer-in-Charge. Note:- (i) Sand and gravels if required to be replaced shall be measured and paid as supply only under relevant items here-in-after. (ii) Chemical analysis Lab test : (1. Turbidity 2. Iron 3. PH 4. Silica ) of IR Plant treated water of various area from Govt. approved laboratory including collection of water in sterillized bottle for testing and submission of the test report
(iii) Testing is to be carried out on each plant once in every qtr)
4
-
-
... More
M&L for quarterly cleaning of RO water storage tank of cap 5000 ltrs with bleaching powder by blocking the inlet/outlet flow from manholes, lifting the excess semi-solid water out of the sump, removing the entire deposited sludge, mud, silt etc scrapping the internal wall/floor with wire brush (to remove deposited scales, mud etc from the walls/floors by using suitable T&P manually from the bottom of the tank) and removing the same at a distance n exc 50m from the site where directed,opening the blocked holes etc before normalising flow complete all as specified and as directed by Engr -in-charge. Note (i) contractor has to pump out the storage water at his own arrangement before cleaning the the tank)
(ii) All cleaning should be done on quarterly basis from srl no. 1 to 4.
16
-
-
... More
Supply only sodium bicarbonate food grade ( Anti chlorine) complete all as specified and directed by Engr-in-Charge. Make : Tata/Enmark
100
-
-
... More
M&L for replacement of polypropelene strainers rings type of iron removal water treatment plant duly after taking out existing wornout one complete all as specified and directed.
2500
-
-
... More
Supply only Gravel 1/2" to 1/3"
4
-
-
... More
S&F reverse osmosis membrane of cap 10 LPH( 80 gpd) model No. INDRO including taking down old unsv one complete all as specified and directed by Engr-in-Charge.
Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
2
-
-
... More
S&F reverse osmosis membrane of cap 250 LPH model No. INDRO-43 including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
10
-
-
... More
Activated carbon media complete all as specified and directed by Engr-in-Charge.
120
-
-
... More
Supply only dia phram valve for DDP including taking out the old unserviceable one.complete all as specified and directed.
3
-
-
... More
Iron removal media complete all as specified and directed by Engr-in-Charge.
180
-
-
... More
S&F micron catridge capacity 10" slim as in repaircomplete all as specified and direted by Engineer-in-Charge.
10
-
-
... More
Supply only Multigrade filter mediacomplete all as specified and directed by Engr-in-Charge.
120
-
-
... More
Dismantling the PVC body multigrade filter unit, (NFMG 20) of RO frontal pipe line and valves, un loading the media and cleaning media i.e pebbles, gravels using chemical as approved by manufacturer, replacement of filter media with new one, servicing of multi port valve, Refilling the media as per original complete including topping up and re-installation of unit and testing complte all as specified and as directed.
Make : ION Exchange or equivalent as approved in Multitex Engg
Note : (i) Fixing and unloading charges shall deemed to be included in the quoted rate.
(ii) Spare parts will be measured and paid separately as supply only.
6
-
-
... More
Supply only traditional calcium hypochlorite based Granular disinfectant for water treatment packed in 45 KG plastic Drum complete all as specified and directed. Make : ALTOCH GP/Decliback/Aquafit.
1200
-
-
... More
S&F carbon block filter 20x2" including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent .
14
-
-
... More
Supply and fixing and testing pressure pump of head range: 6-24 m of capacity 0.5 HP complete all as specified and as directed.
Make-Crompton greaves. Model : miniforce II
2
-
-
... More
S&F reverse osmosis membrane of cap 500 LPH model No. INDRO-43 including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
4
-
-
... More
All as per item No 01 here-in- before but service tank 1000 Ltr capacity
12
-
-
... More
S&F reverse osmosis membrane of cap 1000 LPH model No. INDRO-43 including taking down old unsv one complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Hydronatics/ion exchange/Multitex engg or equivalent.
2
-
-
... More
Supply only Anti sclalant complete all as specified and directed by Engr-in-Charge. Make : Ion exchange/Enmark
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements