Metro Railway Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Metro Railway Tender

Works
Civil And Construction
Civil Works Others
Ireps
Opening Date4 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 7,29,33,099.1 
Notes
Download

Costs

Summary

Renovation, Repair And Interior Works Of 120 Dps Road (annex Of Rpf Barrack), Tollygunge Of Metro Railway, Kolkata.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
REPAIRS TO BUILDING // Repairs to plaster of thickness 12 mm to 20 mm in patches 4 of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. // With cement mortar 1:4 (1cement: 4 coarse sand)

750

478

458880

... More
EARTH WORK // Earth work in excavation by mechanical means (Hydraulic 5 excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. // All kinds of soil

45

205

11833.92

... More
EARTH WORK // Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

33.75

253

10970.64

... More
EARTH WORK // Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : // Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: // With Chlorpyriphos E.C. 20% with 1% concentration

111.2

32

4597.45

... More
CONCRETE WORK // CEMENT CONCRETE (CAST IN SITU) // Providing and laying in 8 position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : // 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

39.52

7365

372570.53

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Providing and laying in position 9 specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : // 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)

10

8364

107061.76

... More
REINFORCED CEMENT CONCRETE // CAST IN SITU // Providing and laying up to floor 10 five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

15

9801

188193.6

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Foundations, footings, bases of columns, etc. for mass concrete

65

307

25621.44

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

95

669

81417.28

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Suspended floors, roofs, landings, balconies and access platform

812.5

766

797212.01

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Lintels, beams, plinth beams, girders, bressumers and cantilevers

110

608

85655.68

... More
REINFORCED CEMENT CONCRETE // FORM WORK // Centering and shuttering including strutting, propping etc. and removal of form for // Columns, Pillars, Piers, Abutments, Posts and Struts

190

804

195593.6

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. // Thermo-Mechanically Treated bars of grade Fe-500D or more.

500

89

57376

... More
REINFORCED CEMENT CONCRETE // STEEL REINFORCEMENT // Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. // Thermo-Mechanically Treated bars of grade Fe-500D or more.

750

89

86064

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: // Cement mortar 1:4 (1 cement : 4 coarse sand)

12

6882

105707.52

... More
MASONRY WORK // Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : // Cement mortar 1:4 (1 cement : 4 coarse sand)

35

8512

381342.08

... More
MASONRY WORK // HALF BRICK MASONRY // Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : // cement mortar 1:4 (1 cement : 4 coarse sand)

60

837

64346.88

... More
MASONRY WORK // HALF BRICK MASONRY // Half brick masonry with common burnt 21 clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. // Cement mortar 1:4 (1 cement :4 coarse sand)

185

1018

241074.24

... More
CLADDING WORK // Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias 22 and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. // Granite stone slab of colour black, Cherry/Ruby red // Area of slab over 0.50 sqm

42.17

4425

238869.77

... More
CLADDING WORK // Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in 23 white cement complete. // Providing and fixing 75mm high, 50mm deep and 18mm thick stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. // Granite Stone of approved shade

15

3542

68022.72

... More
CLADDING WORK // STONE WORK DRY CLADDING // Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of 24 approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

558.11

1063

759708.26

... More
WOOD AND P.V.C. WORK // FRAMES AND TRUSSES // Providing wood work in frames 25 of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). // Sal wood

2.3

106720

314186.18

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed 26 shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Float glass panes // 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).

110

2231

314152.96

... More
WOOD AND P.V.C. WORK // Providing and fixing glazed shutters for doors, windows 27 and clerestory windows using 4 mm thick float glass panes, (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. // Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured).

88.84

147

16733.2

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board 28 etc. : // Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. // 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

118.98

3086

469995.75

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : // 2nd class teak wood // 50x12 mm

459.3

191

112613.02

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing 30 M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. // Fixed to openings /wooden frames with rawl plugs screws etc.

2368

197

599236.61

... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing 40x5 mm flat 31 iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

293

194

72889.02

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : // 250x10 mm 9.81.1 72.00 Each 205.10 14767.20 28.00 18902.02 33

72

374

34500.1

... More
WOOD AND P.V.C. WORK // BRASS FITTINGS // Providing and fixing bright finished brass handles with screws etc. complete: // 125 mm

-

-

33

... More
WOOD AND P.V.C. WORK // CHROMIUM PLATED BRASS FITTINGS // Providing and fixing chromium plated brass handles with necessary screws etc. complete: // 125 mm

72

226

20874.24

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic 35 brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (+/-0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.

130

545

90787.84

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (+/- 0.2 mm), with inbuilt bead on one side, styles and rails mitered 36 cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( +/- 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge.

41

3654

191785.54

... More
WOOD AND P.V.C. WORK // Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : // Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, 37 G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

23

7249

213437.06

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 38 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)

3

7634

29314.94

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length 39 (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).

108

9642

1332993.02

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 40 stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer- in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. // Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm)

68

6940

604096.77

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner 41 set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately)

33

423

17897.09

... More
STEEL WORK // Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making 42 curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

179.25

612

140474.64

... More
STEEL WORK // Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : // 5.5 mm thick glass panes (weight not less than 12.50 kg/sqm)

129.21

1243

205660.98

... More
FLOORING // KOTA STONE FLOORING // Kota stone slab flooring over 20 mm (average) 44 thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : // 25 mm thick 11.27 7.27 Sqm 2038.55 14820.26 28.00 18969.93

32.81

1706

71671.74

... More
FLOORING // KOTA STONE FLOORING // Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

-

-

45

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% 46 and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. // Size of Tile 800x800 mm

661.08

1879

1590780.61

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 47 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. // Glazed Vitrified tiles Matt/Antiskid finish of size // Size of Tile 600 x 600 mm

170

1311

285284.48

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and 48 conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. // Size of Tile 1000x1000 mm

783

2604

2610584.64

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and fixing Glass mossaic tiles on 49 finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:

57

3282

239491.2

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building 50 all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : // Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

58.16

2589

192804.58

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered 51 flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : // 12.5 mm thick tapered edge gypsum moisture resistant board

60

1300

99878.4

... More
ROOFING // Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. // Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main T at 600 52 mm centre to centre to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T', bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in- Charge.

660

1718

1451957.76

... More
FINISHING // 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.

1189.38

217

331123.39

... More
FINISHING // CEMENT PLASTER (IN COARSE SAND) // 15 mm cement plaster on rough side of single or half brick wall of mix: // 1:4 (1 cement: 4 coarse sand)

2453.24

354

1113182.18

... More
FINISHING // CEMENT PLASTER (IN COARSE SAND) // 12 mm cement plaster of mix : // 1:4 (1 cement: 4 coarse sand)

1054.2

307

414595.78

... More
FINISHING // Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : // Water thinnable cement primer

4578

64

377666.69

... More
FINISHING // Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : // Two or more coats on new work

4578

137

807778.94

... More
FINISHING // EXTERIOR FINISHING // Finishing walls with Acrylic Smooth exterior paint of required shade : // New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1465

166

312877.12

... More
FINISHING // EXTERIOR FINISHING // Applying priming coat: // With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

70

61

5505.92

... More
FINISHING // EXTERIOR FINISHING // Applying priming coat: // With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

264

55

18754.56

... More
FINISHING // Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : // Two or more coats on new work

264

131

44419.58

... More
FINISHING // Applying priming coats with primer of approved brand and manufacture, 62 having low VOC (Volatile Organic Compound ) content. // Painting (one or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work : // 100 mm diameter pipes

150

30

5798.4

... More
FINISHING // EXTERIOR FINISHING // Finishing walls with textured exterior paint of required shade : // New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 17.2.2 36.00 Each 5426.80 195364.80 28.00 250066.94 64

93.57

245

29343.55

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : // W.C. pan with ISI marked black solid plastic seat and lid

-

-

64

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes 65 respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : // One urinal basin with 5 litre white P.V.C. automatic flushing cistern

9

5268

60697.15

... More
SANITARY INSTALLATIONS // Providing and fixing wash basin with C.I. brackets, 15 66 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: // White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

59

2275

171808

... More
SANITARY INSTALLATIONS // Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 68

51

1411

92119.87

... More
SANITARY INSTALLATIONS // Providing and fixing toilet paper holder : // C.P. brass

42

680

36599.81

... More
SANITARY INSTALLATIONS // Providing and fixing white vitreous china extended wall 69 mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

36

13036

600724.22

... More
SANITARY INSTALLATIONS // Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal.

9

15968

183958.85

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 71 (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal work - Exposed on wall // 15 mm nominal dia Pipes

60

255

19653.12

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 72 (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal work - Exposed on wall // 20 mm nominal dia Pipes

80

325

33290.24

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 73 (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal work - Exposed on wall // 25 mm nominal dia Pipes

75

408

39220.8

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 74 (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal work - Exposed on wall // 32 mm nominal dia Pipes

120

500

76945.92

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass 75 threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge, Concealed work, including cutting chases and making good the wall etc. // 15 mm nominal dia Pipes

760

441

429150.72

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 76 (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge, Concealed work, including cutting chases and making good the wall etc. // 20 mm nominal dia Pipes

200

513

131520

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 77 (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.-External work // 15 mm nominal dia Pipes

50

221

14166.4

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 78 (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.-External work // 20 mm nominal dia Pipes

60

275

21139.2

... More
WATER SUPPLY // C.P.V.C. PIPES // Providing and fixing Chlorinated Polyvinyl Chloride 79 (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.-External work // 25 mm nominal dia Pipes

40

370

18977.28

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : // 15 mm nominal bore

172

348

76802.82

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : // 20 mm nominal bore

24

397

12209.66

... More
WATER SUPPLY // BRASS FITTINGS // Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : // 25 mm nominal bore

24

399

12261.89

... More
WATER SUPPLY // C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES // Providing and 83 placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

32000

9

397312

... More
WATER SUPPLY // C.P. BRASS FITTINGS // Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. // 15 mm nominal bore

43

715

39356.35

... More
WATER SUPPLY // C.P. BRASS FITTINGS // Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. // 15 mm nominal bore

134

594

102011.52

... More
DRAINAGE // Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement 86 mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : // Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : // With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 21.1.1.3 10.00 Kg 474.70 4747.00 28.00 6076.16

6

24405

187437.31

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For fixed portion // Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

-

-

87

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, 88 straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) // Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

10

573

7339.52

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, 89 straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): // With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

10

1019

13053.44

... More
ALUMINIUM WORK // Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides 90 with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : // Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. // Upto 5mm depth and 5 mm width

5

85

545.6

... More
WATER PROOFING // Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in 91 recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 22.6 850.74 Sqm 585.55 498150.81 28.00 637633.04 92

1439.61

774

1426711.09

... More
WATER PROOFING // Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.

-

-

92

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ 93 or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge // 75mm average thickness

320

311

127774.72

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // 94 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. // Bars upto 12 mm diameter

140

6

1191.68

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a 95 minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer- In-Charge. // Upto and including 12mm dia.

50

121

7804.8

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // 96 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. // Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

150

390

74966.4

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Providing and laying SBR Polymer modified (of approved make @ minimum 2% by wt. of cement 97 used) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness all-round existing core of RCC member. // 75mm thick in Grade M 25 with cement content not less than 330 kg per cum

200

850

217817.6

... More
NEW TECHNOLOGIES AND MATERIALS // REPAIR AND REHABILITATION ITEMS // Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having 98 the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in- Charge // 75mm thick in Grade M 25 with cement content not less than 330 kg per cum

75

1530

146908.8

... More
NEW TECHNOLOGIES AND MATERIALS // NEW TECHNOLOGY ITEMS // Water 99 proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred first & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls.

95

135

16513.28

... More
NEW TECHNOLOGIES AND MATERIALS // Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles 100 should have Humidity Resistance (RH) of 99%, Light Reflectance greater than or equal to 85%,Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main T. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge // With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7)

639.49

2362

1933490.34

... More
CLADDING WORK // Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. // Wedge expansion type // Fastener with threaded dia 6 mm

3000

30

118080

... More
WOOD AND P.V.C. WORK // GYPSUM BOARD PARTITIONS // Providing & Fixing 102 decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. // 1.5 mm thick

230

890

262177.92

... More
CLADDING WORK // Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias 103 and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. // Granite stone slab of all colour and texture except black, Cherry/Ruby red // Area of slab upto 0.50 sqm

18.45

3555

83965.5

... More
CLADDING WORK // Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base 104 cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. // Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. // Granite work

21

418

11258.69

... More
CLADDING WORK // Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. // 8mm thick // Granite of any colour and shade

75

3105

298128

... More
CLADDING WORK // Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. // Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and 106 pattern (if required with marble stone slab pieces of different shapes, sizes & texture but of even thickness) on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. // 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc.

30

9278

356311.68

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed 107 shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Second class teak wood // 35 mm thick shutters

14.86

3704

70461.61

... More
WOOD AND P.V.C. WORK // Providing and fixing panelled or panelled and glazed 108 shutters for doors, windows and clerestory windows, fixing with butt hinges of required size withnecessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) // Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : // Second class teak wood

14.4

2998

55264.67

... More
WOOD AND P.V.C. WORK // Providing and fixing 25 mm thick shutters for cup board 109 etc. : // Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: // 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

20.37

2015

52557.86

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% 110 and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. // Size of Tile 1000x1000 mm

405.72

2551

1325282.75

... More
FLOORING // VITRIFIED FLOOR TILES // Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 111 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. // Glazed Vitrified tiles Matt/Antiskid finish of size // Size of Tile 800 x 800 mm

265

1544

523792.64

... More
FLOORING // VITRIFIED FLOOR TILES // Grouting the joints of flooring tiles having joints 112 of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. // Size of Tile 1000x1000 mm

405.72

146

76132.54

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the 113 manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 12.31.1 500.00 Sqm 1421.25 710625.00 28.00 909600.00

-

-

386038.78

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992, A) (i) Single Socketed 3 Meter Length, (b) 110 mm

308

292

89936

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992, (B) Fittings, (i) Coupler, (b) 110 mm

90

85

7650

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992, (B) Fittings, (ii) Plain Tee, (b) 110 mm

36

85

3060

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992, (B) Fittings, (iii) Door Tee, (b) 110 mm

36

195

7020

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992, (B) Fittings, (v) Plain Y, (b) 110 mm

36

206

7416

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or 6 R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer_x0002_in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground, (ii) 110 mm dia.

290

57

16530

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or 7 R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer_x0002_in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B) Below ground, (ii) 110 mm dia.

18

84

1512

... More
Supplying & laying of approved brand of scratch proof, semi flexible P.V.C. blended 8 homogeneous marble Vinyle flooring in tiles conforming to IS:3461, fixing with synthetic acrylic adhesive after preparing the floor, levelling & smothaning when necessary with suitable putty, as per the design & instruction of the Engineer-in-charge. 2mm thick

140

578

80920

... More
Supplying 6mm thick ply, fitting and fixing boiling water proof ply conforming to IS: 9 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer in Charge. [ excluding the cost of supporting frame work and teak wood batten/Lipping]

20

923

18460

... More
Supplying 12mm thick ply, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer in Charge. excluding the cost of supporting frame work and teak wood batten/Lipping.

-

-

10

... More
Supplying 19mm thick ply, fitting and fixing boiling water proof ply conforming to IS: 11 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer in Charge. [ excluding the cost of supporting frame work and teak wood batten/Lipping]

20

1871

37420

... More
Supplying, fitting and fixing of False ceiling frame work with powder coated exposed GI Grid suspension system (E-Grid T 2430/1510 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm / 600mm long and Wall angle. The wall angle shall be fixed on PVC 12 Dash fastners on the perimeter of the wall by steel screws with distance 300mm c/c. The Runners to be placed @ 1200mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at regular interval of 600 mm to foam a modular grid of 1200mm x 600mm. Additional Cross Tees of 600mm shall be placed perpendicular to the Cross Tee 1200mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins / soffit all complete as per drawing & directions of Engineer-in-charge.

650

341

221650

... More
Providing, erecting & finishing of Decorative False Ceiling partly finish with Natural 13 wooden veneer in PU polish finish and partly with Gypsum Plaster board & Cove light tray, complete in all respect with all necessary labour and materials and as per approved drawing, design & instruction of Engineer in Charge.

180

1595

287100

... More
Providing, erecting & finishing of 12mm thk x 600mm x 600mm Perforated (50mm x 50mm ) Laminate finish panel type Grid ceiling complete in all respect with all necessary labour and materials and as per approved drawing, design & instruction of Engineer in Charge.

228.6

3800

868680

... More
Acoustical False ceiling : Providing and fixing false ceiling having 600mm x 600mm x 15mm thk. grid of "Armstrong" make consisting of frame work of pre-coated hot dipped galvanized steel with a primer and finish coat of Standard Global White Polyester baked paint. The frame work shall comprise of main runner of size 15 x 32 x 3000mm spaced at 1200mm centers securely fixed to the structural soffit by approved hangers at 1200mm maximum centres. Hangers (GI Wire of 2.0mm dia) shall be fixed by approved roof plug, level adjusters and screws etc. The last hanger at the end of 15 each main runner should not be greater than 450mm from the adjusten wall. Flush fitting 1200mm long cros tees of size 15 x 32 x 1200mm to be interlocked between main runners at 600mm centers to form a 1200mm x 600mm module. Cut cross tees longer that 600mm to be supported independently. 600mm x 600mm modules to be forme by fitting 600mm long flush fitting cross tees of size 15 x 32 x 600mm centrally between the 1200mm cross tees. Perimeter wall angle of size 19 x 19 x 3000mm secured to walls at 450mm maximum centres. Finally lay approved Armstrong Pre painted OPTRA WHITE TILES of size 595mm x 595mm in the frame work. The entire work is to be completed in all respect with all labour & materials & as per drawing, design & instruction of E I C. (No deduction to be made for AC diffusers & false

254

3500

889000

... More
Providing, erecting & finishing of Wall panelling with MDF Board partly with natural 16 wooden veneer tiles & partly with artificial leather in approved design complete in all respect with all necessary labour and materials and as per approved drawing, design & instruction of Engineer in Charge.

250

5350

1337500

... More
Providing & pasting of Decorative Wall paper of approved texture complete in all respect with all necessary labour and materials and as per approved drawing, design & instruction of Engineer in Charge.

110

1230

135300

... More
Providing, erecting & finishing of Wall panelling with wooden veneer finished with PU polish in approved design complete in all respect with all necessary labour and materials and as per approved drawing, design & instruction of Engineer in Charge.

420

4750

1995000

... More
Acoustical linning on side & back wall : lower part: Providing & Fixing of wall panel by G.I. frame work with 600 x 300mm c/c to be fixed on wall (chanel section placed 300 c/c and intermediate section will be placed 600 c/c). There after Acoustical backing by Ploy fiber wool of thickness 50mm having density of 20 Kgs/M3 tie up by Galvanized wire mesh and galvanized wire to avoid sagging. On top of GI frame provide wooden Slats 16mm thick Melamine finish having density 800 kg/M3, NRC 0.75 and Fire class 1 &P with a special channel section of CC18. This run of wall panelling to be provided on both side and back wall of the hall partially. Design of wall to be made for popper sound reproduction.

-

-

19

... More
Acoustical linning on Stage side & back wall : Providing, Fitting and fixing of wall panel by G.I. frame work with 600 x 300mm c/c to be fixed on wall, (chanel section placed 300 c/c and inter 20 mediate section will be placed 600 c/c). There after Acoustical backing by Ploy fiber wool having density of 20 Kgs/cum tie up with Galvanized wire mesh and Galvanized wire, to avoid sagging. On top provide mat Ebony acoustical board of pine wood perticle core magnesia bonded 20 mm thick having NRC upto 0.90 density 600Kg/cum and moisture registance RH-90 fire class 1 & P of black colour finish, Design of wall to be made for popper sound reproduction.

52

4500

234000

... More
Frameless Glass door (10mm thk.) in patch fitting with all necessary accessories and labour materials and as per approved drawing, design & instruction of Engineer in Charge. 22

10.5

13750

144375

... More
Providing & applying of PU Polish on Wooden veneer

20

2500

50000

... More
Supply ,fabrication & installation of aluminium powder coated image perforated screen for mural along with aluminium back up frame 24

10

4350

43500

... More
Supply, fabrication & installation of aluminium powder coated duct louver.

132

6500

858000

... More
Scaffolding providing & erecting scaffolding at required ht for erecting of false ceiling , wall panelling, cat walkway, structural glazing etc.

1800

165

297000

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835- 1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II), (ii) 8mm thick

33

1261

41613

... More
Demolishing R.C.C. work (any grade) and disposal of the same up to 25 Km out side 1 Rly. land as per direction of Engineer-in Charge including refund of released reinforcement steel. Released materials will be contractors own property. the rate includes all contractor's labour and materials, tools &plants, lead, lift, taxes etc. complete.

5

-

-2010

... More
Dismantling of brick work of building/boundary wall/structures of any thickness with 2 contractor's labour, tools and disposing the dismantled materias (including briks ) out side Rly land as contractor's own materials , clearing and levelling the area as per the instruction of Engineer . Release materials will be contractor's own property. The rate includes all labour and materials, tools & plants, lead, lift, taxes etc.complete.

20

-

-6260

... More
Dismanting iron collapsible gate, rolling shutter, M.S Grill, M.S gate, Palisade fencing 3 etc. with post and stays including disposal of released materials.(The released material will be contractor's property and value of material will be recovered from bill as per rate under relevant item of the schedule)

200

77

15400

... More
Dismantling doors and window (steel or wood) shutters including choukhat, architravs, hold fastin CC or masonary etc. complete. Released materials will be contractor's own property.

64

-

-100672

... More
Dismantling doors and window etc. (Aluminium) (steel or wood) shutters including choukhat, architravs, hold fastin CC or masonary etc. complete. Released materials will be contractor's own property.

2

-

-330

... More
Dismantling steel work manualy/by mechanical means in built up section s without dismembering and stacking within 50metre lead as per direction of engineer-in- charge. ( The released material will be contractor's property and value of material will be recovered from bill as per rate nder relevant item of the schedule) 7

-

-

6

... More
Recovery of cost of released material

-

-

-21800

... More
Providing and fixing designer Wall Paneling with 3D engraving in 18mm thick acrylic solid surface sheet of approved make or as approved by Engineer basic white color. Design & fixing arrangement as per direction of Engineer. The material should be CNC 3D cut to achieve the desired design. The CNC cut Acrylic solid surface sheet to be fixed in a box frame or on a frame or on a flat 1 surface as per the drawing and design and as per the instrnctions of the Engineer. The material used shall be very translucent and the light shall pass through the acrylic solid surface enhancing the design and the lights passing should be very visible. The cost shall include the framing and Boxing of wood / plywood and the frame should be of stainless steel or wood as per requirement of stability and weight carrying capacity and its requirement for support. The 3D shall be done as per the requirement oflight translucency and reflection of lights required as per the design and instructions of Engineer. The backlit ceiling shall have the light passing and shall have translucency.

139

19417

2698963

... More
Paneling with acrylic solid surface. Providing and fixing wall cladding panels with 6mm acrylic solid surface, non-porous and homogeneous seamless, stain resistant, repairable, durable, hygienic environment friendly surfacing material acrylic solid surface sheet of or approved make with 2 a minimum thickness 06 mm in color, design, fixing m customize design arrangement as per direction of Engineer. Acrylic solid surface sheet to be fixed on wall on top of 12 mm marine ply. Adhesive of the same color to provide inconspicuous joints. Grooves to be given at every 1mtr to give expansion & contraction movement to material. The rate 1s inclusive of all operation, material and required pattern. Cost of base like framework and 12mm thick ply will be paid under respective item.

126.2

7505

947131

... More
Providing & Fixing premium quality Manually operated Roller blinds with Solar protection fabric of high tenacity Polyester Yarn with PVC Coating & Grey Backing, & offer 100% blackout / heat radiance. Fabric shall have GREENGUARD (Gold) Indoor Air Quality & Children & School Certified. Weight: 300 to 350 g/m2 (+/-5%), Thickness: 0.47 to 0.55 mm (+/-5%), Fabric Openness Factor: 0%, Tensile Strength (Warp/Weft): 160/170 daN / 5cm, Tearing Strength (Warp/Weft): 11/13 daN, Solar Transmission- 0%, Solar Reflectance 25-69%, Solar Absorption 28-31%, Fungistatic Treatment: Degree 0, Excellent (EN ISO 846-A). Roller Tube shall be of extruded Aluminium alloy 38mm O.D (or as per system dimension) with a minimum wall thickness of 1.0mm duly anodised for long life.Clutch shall be wrap spring design with high strength fibreglass reinforced polyster assembly 3 and high carbon steel springs to transmit motion from driving to driven members of clutch mechanism. Clutch shall operate by directionally with the use of an endless beaded chain. Clutch mechanism shall be crash proof, prevent slippage and shall raise and lower smoothly to any desired height. Clutch shall never need adjustment. Idler shall be of high strength fibreglass reinforced polyster, consisting of an outside sleeve and centre shaft. Sleeve shall provide bearing surface for roller tube and rotate freely on centre shaft, providing smooth, quiet and long wearing operation. Brackets shall be of tomised steel powder coated to give superior finish. Bracket shall accommodate overhead, side or face mounting with clutch assembly on either end of the roller.Bottom of the blind shall be provided with aluminium tube powder coated in a colour matching to the fabric. The fabric shall be enclosed in the suitably created pocket along with the tube. The tube shall be closed from sides with end caps.

225.17

1729

389318.93

... More
Modular rest rooms made of solid grade compact high pressure laminates as per IS : 4 2046 and EN 438. Standar dimension 2100X900X1550. Door dimension 1925 X 600 supported by 3 nos SS hinges. Pilaster dimesion 2100 X 300 supported by SS studs. Standard bottom gap 100 mm to 150 mm. All intermediate partitions / dividers to be made of 12mm thick HPL compact laminate panels afixed with SS made U channels at their ends for stability.

10

18000

180000

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

400

245

98000

... More
Providing and fixing of Lacquered Glass. 6 mm Extra Clear Glass used for lacquered glass should be of Saint Gobain/ ASAHI/ Pilkington and should be toughened in horizontal tempering line. Lacquered glass could be fixed with (Dow coming - 789) / Pentagon double sided tape @ 2-3 per Sqm) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fiber board which 6 is mounted on the RCC wall/any other structure Or installed using Stainless Steel Patch fitting Or Stainless Steel studs Or Aluminum frame. (Ply, MDF, MFB, SS Fitting, Aluminum Frame etc. to be paid separately) Lacquered glass to be made industrially (via air brushing process); opaque (if viewed against a support wall), coated with WATER BASED lacquer colour of brand Colour Spray AQUA by Regaled - United Kingdom Or Equivalent Brand ;Which is binded by Nano particle pure acrylic); Gloss Level - 40 ; where VOC < 1% ; highly durable ; humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, no formaldehyde; compressive strength (1000 MPa) & tensile strength (40 MPa),same as float glass as per the detailed drawings and as approved by Engineer. Colour to be checked and tested via INDEX Colour shade card used worldwide as a colour choosing parameter.

54

6965

376110

... More
PERFORATED ZINC TITANIUM CLADDING : Supply, & Installation of Titanium zinc Interlocking wall cladding panels in Pre Patina BLUEGREY/GRAPHITE GREY Finish. The wall cladding system shall comprise of the following described 0.8/1 mm interlocking panels of 250-300 mm width and max 1000 mm length. The interlocking panels are to be fixed using necessary accessories as 7 proposed by suppliers standard methodology and connected end to end. Screws should be of SS Grade 410.Rivets powder coated in same finish ans the sheets and made of Aluminium. The substructure should be erected using Aluminium box sections of 25/30 x 50/60 dimensions. The Zinc sheets shall be as per EN 988 standards and must have TUV Certifications. The sheets should be purely natural without addition of any pigmentations. Perforation : Custom CNC punching as per approved drawings . Circular perforation of varying diameters shall be done as per approved drawings to meet the facade intent .

40

6061

242440

... More
Supplying and laying wooden flooring at site 8mm thick of approved make using click laminated floor with inbuilt 3mm sound bloc class of use 31 water resistant AC 3 grade impact resistant IC3 (as per EN 130 900 / 1400) having 0.60mm MLC (Multi-Layer Guard + SRSG 2) (Scratch 8 Resistant surface Second Generation) on top of moisture high density fibre board substrate specially developed copr of plank size 1288 x 196 x 8mm having joints tongue and groove to secure long lasting joint. The tongue and groove having the edges duly pre impregnated with par affine including laying 0.20mm thick alkali resistant polyethylene sheet of density 850 kg / m3 beneath the laminated wooden panel to absorb the sound caused including labour charges, loading, unloading, transportation, etc., complete

29

3545

102805

... More
Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 9 confirming T is - 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer

1040

4836

5029440

... More
Providing & fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / tapping screws / fasteners @ 60cm c/c of approved make. A groove of 2mm to 3mm shall be maintained and grooves shall be sealed with silicon base sealant. The board shall be fixed in a staggered pattern. Csrews shall be counter sunk rib head of 1.6mm to 4mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and and internal 10 face 12.5 mm thick gypsum plaster board fixed board fixed on cement board as per standard sizes fixed with self drilling / tapping screws / fasteners @ 60mm c/c of approved make, proper tapping & jointing to be done using fiber mesh tape and epoxy & acrylic base jointing compound for seam,less finish. (Cost for framework to be paid for separately). Outer face having 8mm thick cement bonded particle board fixed on 10mm thick cement bonded particle board. (Termite, fire & moisture resistance) as per IS 14276:1995. Inner face 12.5mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8mm thick cement bonded particle board (Termite, fire & moisture resistance) as per IS 14276:1995.

170

3167

538534.5

... More
3300 Ansi Lumens Short Throw Projector, WXGA (1280 X 800) Resolution, Contrast Ratio: 3000:1

2

99180

198360

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to 12 finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Using R4 series with frame (115mm & above) x(45mm & above) & sash (30mm & above) x (55mm & above)with zinc alloy (zamak) powder coated handle on two end panelsalong with multi point locking system (height upto 1.8 metre)

31.6

9888

312471.86

... More
Ventilator casement window single panel with or without fixed panel with SS 304friction 13 hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles.Using R2 series with frame (39mm & above) x(39mm & above) & sash / mullion (39mm & above) x (60mm & above). (height upto 1.2 metre)

2.88

12254

35291.52

... More
Casement window double panel with fixed mullion with SS 304 friction hinges as per 14 size & weight of sash multipoint locking zinc alloy (zamak) powder coated handles.Using R4 series with frame (64mm & above) x (50mm & above) & sash (64mm & above) x (70mm & above) & mullion (64mm & above) x (70mm & above). Height above 1.8 metre

4.86

13477

65498.71

... More
Providing and laying full body Vitrified tiles in floor of minimum thiskness 15mm with water absorption less than 0.06% and conforming to IS: 15622, of approved brand & manufacturer, 15 laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with zero chipping diamond cutter only. Laying of slab shall be done with the help of notch trowel, wedge, clips of required thickness, vaccum cups for lifting, levelling system & rubber mallet for placing the slab gently & easily. Size of tile 800 X 2400 mm of all colours and shades.

183.33

3623

664378.75

... More
Supplying and installation of Anutone / Topakustiks / Idea Tec / Wood Fit / Equivalent Brand of Acoustic Wooden Wall Panelling with fire retardant grade pine wood fibre slats of size 2430 x 128 x 16mm with lineal perforation of 2mm back lined with soundtex black acoustical fleece 0.27mm thick, 63 g / m2, tongue-groove edge for a seamless look, 5 test fire retardant grade with noise 16 reduction coefficient not less than 0.75 NRC to absorb low and mid range frequencies from 125Hz to 4000Hz. GI strut CC50 frame work not more than 60 cm centre to centre using GI channels are fixed on the wall, over which an acoustic filling polywool material sound synth of 500 gsm density of 50mm thick has fixed and finally the panels are fixed and finished, so as to have an neat appearance as directed by the departmental offices. The cost includes cost of material, cost of Labours, scaffolding, transportation, conveyance, etc., complete complying to standard specication. "

163.72

9265

1516865.8

... More
Smart LED TV with Actual Screen Size (inches) 75. (Spec:- Minimum Audio Power 20W x 1 2; Resolution supported upto 3840x2160; operating system- android; min. TV channel supported (at RF input)- 16; inbuilt speakers with table & wall mount bracket; HDR; Screen mirroring; built-in Wi-fi, wi-fi direct, Bluetooth, LAN; Input port- RF input, video component input, HDMI port-1, USB port-1, ethernet port; warranty- 1 years; with installation & commissioning).

2

85766

171533

... More
Projector Screen 150 inches. (Spec:- min resolution supported- 1080p, 4K, 3D; SUPPORTED ASPECT RATIO- 1:1, 3:4; On site OEM warranty- 2 years; type of screen pulling - motorised; colour of screen- white; with wall mount fixtures for each screen). 3

2

11218

22436

... More
TV Stand for 75 inch LED TV with all accessories.

2

18500

37000

... More
Provision of controlling device for display system with latest specification like 13th gen processor or latest, OS-win 11 latest with networking feature with MS Office. (spec:- i7, 13th gen, win 11 professional; 8GB RAM and expandable upto 64 GB; 1024 GB SSD; wireless connectivity with wi-fi, Bluetooth 5.2 or latest with HDMI port, USB Port, 14 inch, non-touch, 1920x 1080 resolution with webcam integrated with display in HD supported). 5

1

75000

75000

... More
Installation & Labour charges with required accessories.

1

5000

5000

... More
Supply, Installation, Testing & commissioning of 3 KVA online UPS system with 2 Hrs backup (spec:- with battery of 100 Ah, 8 nos, 3 years warranty for battery; with installation & commissioning; floor standing; 3 KVA rating with 120 min backup).

1

119500

119500

... More
EPSON short Throw Multimedia Projector with 1280 x 800 (WXGA) Resolution (spec:- brightness- 4000 , laser light source, HDMI-2 with audio in and out with video in facility, wifi 7 connectivity, wireless screen share, LAN connectivity, LCD technology, projection method- Front and rear both, reso.- 1280x 800 (WXGA), min contrast ratio- 250000:1; remotely controlled , short throw (0.41 to 0.9), aspect ratio- 16:10, keystone correction- automatic & manual both, inbult speaker of 16 watt min.,; on site OEM warranty- 3 year ).

2

120398

240796

... More
Supply & installation of 150w RGBNW IP66 LED Floodlight including all accessories. 2

2

112100

224200

... More
Supply & installation of 80w RGBNW IP66 LED Floodlight including all accessories. 3

3

53100

159300

... More
Supply & installation of 27w RGBNW IP66 LED Floodlight including all accessories. 4

39

25960

1012440

... More
Supply & installation of 36w RGBNW IP66 LED Floodlight including all accessories. 5

31

41300

1280300

... More
Supply & installation of Uni Linear IP68 Cove lighting including all accessories. 6

58

33040

1916320

... More
Supply & installation of 27w RGBNW IP66 LED Floodlight including all accessories. 7

26

25960

674960

... More
Supply & installation of 60w RGBNW IP66 LED Floodlight including all accessories. 8

26

63720

1656720

... More
Supply & installation of 18w IP66 LED Linear Glazing light including all accessories. 9

43

33040

1420720

... More
Supply & installation of 35w IP66 LED Post Top light including all accessories. 10

4

29500

118000

... More
Supply & installation of 8w IP65 LED Bollard light including all accessories.

30

10620

318600

... More
Supply & installation of 1000 lumen recessed LED Downlight Dali version with system efficacy > 120 lm/w

267

8260

2205420

... More
Supply & installation of 1000 lumen recessed LED Downlight Non Dali version with system efficacy > 120 lm/w 13

48

2596

124608

... More
Supply & installation of 30w 2000 lumen recessed LED Linear Non Dali version.

12

9440

113280

... More
Supply & installation of 3000 lumen recessed LED Downlight Non Dali version with system efficacy > 120 lm/w

18

10620

191160

... More
Supply & installation of 800 lumen recessed LED Downlight Dali version with system efficacy > 120 lm/w

5

7670

38350

... More
Supply & installation of 1200 lumen surface LED Downlight Non Dali version with system efficacy > 120 lm/w

8

1416

11328

... More
Supply & installation of 1200 lumen recessed LED Downlight Non Dali version with system efficacy > 120 lm/w

24

2950

70800

... More
Supply & installation of 2000 lumen recessed LED Downlight Dali version with system efficacy > 120 lm/w

30

10030

300900

... More
Supply & installation of 800 lumen recessed LED Downlight Non Dali version with system efficacy > 120 lm/w 20

7

2360

16520

... More
Supply & installation of 5mtr LED strip light including driver

44

2596

114224

... More
WIRING IN STEEL CONDUIT // Wiring for light point/ fan point/ exhaust fan point/ call 21 bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable , etc. as required (Group C)

800

1920

1536528

... More
Wiring for circuit / sub main wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit as required (2 X 4 sq.mm + 1 X 4 sq.mm earth wire)

500

388

194385

... More
Wiring for circuit / sub main wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit as required (2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire)

500

450

225465

... More
Supply & erection of 6 way SPN DB with 32 A DP RCBO as incomer and 3 nos 16A DP MCB & 3 nos 10A SP MCB as outgoing as per specification.

10

9074

90744



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.