MECON Limited Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
MECON Limited - MECON Tender
Software and IT Solutions
Machinery and Tools
Eprocure
Opening Date12 Mar 2025
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 1,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Automation System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MECON_229806_1Tender No
M0065/Automation/Pkg22/15 dated 12.03.2025Tender Authority
MECON Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Training at site for 4 engineers for 5 days
20
-
-
... More
AO Card
1
-
-
... More
I/O cards, communication cards, power supply cards, MCB, TBs and other accessories with mounting plate required for retrofitting in enclosure of existing BLT I/O panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
3
-
-
... More
Loose spare 4 channel A0 card of BLT, Skip & RMHS Automation System
1
-
-
... More
32 Channel DI Card
2
-
-
... More
Engineering Stations as per TS & Automation Configuration Diagram (ACD).
5
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing RMHS PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
Two years Spares to be supplied in compliance with above supplied items
-
-
-
... More
BF Pump House Hot redundant PLC system as per TS & Automation Configuration Diagram (ACD).
1
-
-
... More
Fibre optic (FO) cables armoured & single mode 6C – (All 6 cores shall be terminated in LIU).
1500
-
-
... More
Loose spare 16 Channel AI card of BLT, Skip & RMHS Automation System
1
-
-
... More
Additional Analog Output Card along with connector & TB.
1
-
-
... More
Power supply units
2
-
-
... More
Control console desk (for installation of all HMI Operator Stations, engineering stations, printers etc) for Pump House control room shall be of modern & aesthetic design with Cable Management system. Control console shall have facility for post-mounted monitor arm with height adjustment for all HMI stations, Power socket outlet with spare and all hardware accessories mounting plates/ rails with tilting mechanism. Processor of Operator station & Engineering station shall be located on bottom cabinet.
Console structure shall be made of heavy-duty aluminium. Surface of console shall be made up of highly durable and high density laminate applied to a heavy duty MDF/ better board. Surface top should be fire retardant, scratch, moisture, stain and dent resistant. Control console desk shall have ergonomic design with dark base behind the operator station monitors.
Desk shall include 4 Nos. ergonomic revolving control room chairs.
1
-
-
... More
Additional 32 channel Digital Output card along with connector & TB.
1
-
-
... More
Shielded twisted pair CAT5e / CAT6 cables that complies with TIA/EIA/IEC to protect against the severe disturbance as per recommendation of automation OEM. All cables shall be industrial grade.
500
-
-
... More
Additional 32 channel Digital Output card along with connector & TB.
1
-
-
... More
65’’ Large video Display as per TS & Automation Configuration Diagram (ACD).
4
-
-
... More
A3/A4 printer with two spare cartridges and printer table as per TS.
1
-
-
... More
I/O cards, communication cards, power supply cards, MCB, TBs and other accessories with mounting plate required for retrofitting in enclosure of existing BLT I/O panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
3
-
-
... More
24 Port Industrial Layer-3 Managed Ethernet switch as per TS & Automation Configuration Diagram (ACD).
8
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing RMHS PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
BF Instrumentation & Stoves Hot redundant PLC system as per TS & Automation Configuration Diagram (ACD).
1
-
-
... More
3KVA non-redundant UPS system along with battery bank as per TS.
6
-
-
... More
A3/A4 printer with two spare cartridges and printer table as per TS.
1
-
-
... More
Multimeter
1
-
-
... More
Additional RTD Card along with connector & TB.
1
-
-
... More
HMI Operator Stations as per TS .
10
-
-
... More
Loose spare 8 channel A0 card of BLT, Skip & RMHS Automation System
1
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing BLT PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
Additional Analog Input Card along with connector & TB.
1
-
-
... More
(2X7.5) KVA redundant UPS system along with battery bank as per TS.
1
-
-
... More
Engineering Laptops with software & licenses as per TS.
2
-
-
... More
BF Instrumentation & Stoves RIO system as per TS & Automation Configuration Diagram (ACD). (IO count including spares is indicated below) Type of Signal IO Count (Nos.)
Digital Input - 320
Digital Output - 256
Analog Input - 1160
Analog Output - 60
Quantity of signal Isolator cum duplicator - 948
Quantity of signal Isolator cum duplicator - 121 Alarm Unit - 50 Relay (1 in 2 out 2 NO & 2 NC) - 85
Relay (1 in 3 out 3 NO & 3 NC) - 10 Note:
i. AI signals shall be provided with signal isolator cum duplicators.
ii. DI & DO cards shall be 32 channels.
iii. Number of RIO panels required shall be as per IO count stated above.
1
-
-
... More
Loose spare 24V DC DI card of BLT, Skip & RMHS Automation System
1
-
-
... More
Optical Link Modules (OLM), Light Interface Unit, patch chords, Redundant link modules, media converters, Converters, Terminators, Connectors, Network components like network interface modules, and other miscellaneous hardwares as per requirement of TS & Automation Configuration Diagram (ACD).
1
-
-
... More
Additional 32 channel Digital Input Card along with connector & TB.
1
-
-
... More
HMI Operator Stations software along with licenses as per TS.
1
-
-
... More
Engineering Stations as per TS.
5
-
-
... More
Crimping Tools
1
-
-
... More
Additional Analog Input Card along with connector & TB.
1
-
-
... More
Additional Analog Output Card along with connector & TB.
1
-
-
... More
Shielded twisted pair CAT5e / CAT6 cables that complies with TIA/EIA/IEC to protect against the severe disturbance as per recommendation of automation OEM. All cables shall be industrial grade.
500
-
-
... More
Optical Link Modules (OLM), Light Interface Unit, patch chords, Redundant link modules, media converters, Converters, Terminators, Connectors, Network components like network interface modules, and other miscellaneous hardwares as per requirement of TS.
1
-
-
... More
I/O cards, communication cards, power supply cards, MCB, TBs and other accessories with mounting plate required for retrofitting in enclosure of existing RMHS I/O panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
6
-
-
... More
Universal Hand-held HART calibrator
1
-
-
... More
Additional automation Testing & commissioning engineer services for post-commissioning automation works on call out basis. (This is in addition to Testing & trial run services to be provided by bidder)
100
-
-
... More
Loose spare 8 Channel AI card of BLT, Skip & RMHS Automation System
1
-
-
... More
Control console desk (for installation of all HMI Operator Stations, engineering stations, printers etc) for Pump House control room shall be of modern & aesthetic design with Cable Management system. Control console shall have facility for post-mounted monitor arm with height adjustment for all HMI stations, Power socket outlet with spare and all hardware accessories mounting plates/ rails with tilting mechanism. Processor of Operator station & Engineering station shall be located on bottom cabinet.
Console structure shall be made of heavy-duty aluminium. Surface of console shall be made up of highly durable and high density laminate applied to a heavy duty MDF/ better board. Surface top should be fire retardant, scratch, moisture, stain and dent resistant. Control console desk shall have ergonomic design with dark base behind the operator station monitors.
Desk shall include 4 Nos. ergonomic revolving control room chairs.
1
-
-
... More
Pump House RIO system as per TS & Automation Configuration Diagram (ACD). (IO count including spares is indicated below) Type of Signal IO Count
Digital Input - 983
Digital Output - 288
Analog Input - 188
Analog Output - 30
RTD - 90
Note:
i. AI signals are not required to be provided with signal isolator cum duplicators.
ii. DI & DO cards shall be 32 channels.
iii. Number of RIO panels required shall be as per IO count stated above.
1
-
-
... More
(2X5) KVA redundant UPS system along with battery bank as per TS.
1
-
-
... More
Establishment of existing DSP's Level-2 system communication with new Instrumentation PLC system & Pump House PLC system.
1
-
-
... More
Additional RTD Card along with connector & TB.
1
-
-
... More
Allen keys
1
-
-
... More
32 Channel DO Card
1
-
-
... More
BF Instrumentation & Stoves RIO system as per TS & Automation Configuration Diagram (ACD). (IO count including spares is indicated below) Type of Signal IO Count (Nos.)
Digital Input - 320
Digital Output - 256
Analog Input - 1160
Analog Output - 60
Quantity of signal Isolator cum duplicator - 948
Quantity of signal Isolator cum duplicator - 121 Alarm Unit 50 Relay (1 in 2 out 2 NO & 2 NC) - 85
Relay (1 in 3 out 3 NO & 3 NC) - 10 Note:
i. AI signals shall be provided with signal isolator cum duplicators.
ii. DI & DO cards shall be 32 channels.
iii. Number of RIO panels required shall be as per IO count stated above.
1
-
-
... More
Additional 32 channel Digital Input Card along with connector & TB.
1
-
-
... More
BF Instrumentation & Stoves Hot redundant PLC system as per TS & Automation Configuration Diagram (ACD).
1
-
-
... More
24 Port Industrial Layer-3 Managed Ethernet switch as per TS.
8
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing BLT PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
Table-2
List of equipment for “Erection supervision, Testing & Trial” by Bidder as per TS
-
-
-
... More
NOTE: 1. The quantities indicated above are estimated quantities and may vary during execution. Payment shall be made based on actual quantity executed and unit rate quoted by bidder. 2. Quantity of items indicated above can be ordered as partial lot wise considering the requirement of purchaser and front availability at site. 3. The unit rates quoted shall include all the works/ facilities/ requirements indicated in the specification against each equipment.
4. Shift wise working hours shall be followed when intimated by purchaser. 5. Price indicated against various items in Table-2 is including the man-hours required for erection supervision, testing & commissioning services.
-
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing SKIP PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
Design, engineering (site engineering for retrofitting works and engineering for new supplies), drawing document submission, incorporation of comments and approval as per TS & Automation Configuration Drawing (ACD).
1
-
-
... More
Engineering Laptops with software & licenses as per TS.
2
-
-
... More
Table-1
List of Equipment to be “Designed, engineered & Supplied” by bidder as per Technical Specification
-
-
-
... More
Loose spare 230V AC DI card of BLT, Skip & RMHS Automation System
1
-
-
... More
3KVA non-redundant UPS system along with battery bank as per TS.(including OEM/ Expert supervision on call out basis.
6
-
-
... More
Loose spare 8 channel RTD card of BLT, Skip & RMHS Automation System
1
-
-
... More
RTD Card
1
-
-
... More
Anti-virus software minimum three years license as per TS.
1
-
-
... More
65’’ Large video Display as per TS.
4
-
-
... More
I/O cards, communication cards, power supply cards, MCB, TBs and other accessories with mounting plate required for retrofitting in enclosure of existing RMHS I/O panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
6
-
-
... More
(2X7.5) KVA redundant UPS system along with battery bank as per TS.(including OEM/ Expert supervision on call out basis.
1
-
-
... More
Loose spare DO card of BLT, Skip & RMHS Automation System
1
-
-
... More
PLC processors, I/O cards, communication cards, power supply cards, MCB, TBs and other accessories factory wired in a mounting plate required for retrofitting in enclosure of existing SKIP PLC panel as per TS & Automation Configuration Diagram (ACD).
(Major component retrofitting list provided in TS clause 7.0.2 sub-clause (ii) Retrofitting Works of BLT, Skip & RMHS Automation System)
1
-
-
... More
Fibre optic (FO) cables armoured & single mode 6C – (All 6 cores shall be terminated in LIU).
1500
-
-
... More
(2X5) KVA redundant UPS system along with battery bank as per TS.(including OEM/ Expert supervision on call out basis.
1
-
-
... More
HMI Operator Stations as per TS & Automation Configuration Diagram (ACD).
10
-
-
... More
BF Pump House Hot redundant PLC system as per TS & Automation Configuration Diagram (ACD).
1
-
-
... More
Pump House RIO system as per TS & Automation Configuration Diagram (ACD). (IO count including spares is indicated below)
Type of Signal/ IO Count
Digital Input - 983
Digital Output - 288
Analog Input - 188
Analog Output - 30
RTD - 90
Note:
i. AI signals are not required to be provided with signal isolator cum duplicators.
ii. DI & DO cards shall be 32 channels.
iii. Number of RIO panels required shall be as per IO count stated above.
1
-
-
... More
FO splicing kit
1
-
-
... More
AI Card
4
-
-