Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Kolkata Port Trust - KOPT Tender

Works
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date30 Oct 2024
Closing Date20 Nov 2024
Tender Amount₹ 51,89,900 
Notes
Download

Costs

Summary

Sditc Of 2 Sets Of 50 Hp Vertical Turbine Pump Along With Suitable Induction Motor With A Defect Liability Period Of 2 Years And Non Comprehensive Maintenance Contract For 5years(for New Pump 3 Years After Dlp) For 2 Nos. New Installed Pumps Of Hdc

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 1.1 kV grade, 1C X 25 sqmm. unarmoured, stranded copper conductor, XLPE insulated, PVC inner sheathed, extruded PVC ST2 type outer sheathed power cable (FRLS), conforming to IS: 7098 (Part – I) , with latest amendment (if any), and as per "Technical Specification".

50

-

-

... More
Laying, Testing & Commissioning of 1.1 kV grade, 4 run of 1C X 25 sqmm. unarmoured, stranded copper conductor, XLPE insulated, PVC inner sheathed, extruded PVC ST2 type outer sheathed power cable (FRLS), on wall and fixing by aluminium saddling (approx. 200 mm interval) , with earthing attachment in 10 SWG GI (Hot Dip) 4wire [including supply of materials, as required] , a2s necessary, including mending good damages to building works.

50

-

-

... More
Connecting the leads of 1.1 kV grade, Alumin4ium Conductor, 3.5 C X 50 sqmm. Cable, with MC30CBs / MCBs / SDFUs/ Connectors [after finishing the ends by crimping method , including supplying & fixing solderless sockets , tapes, anticorrosive paste & jointing materials], at Distribution Board / Junction Box / SDFU, as per the 'Technical Specification & Scope of Work.

4

-

-

... More
Providing double compression type Cable Gland, complete with brass gland, brass ring & rubber ring, for dust & moisture-proof entry of 1.1 kV grade, Aluminium Conductor, 3.5 C X 50 sqmm. Cable, as per the 'Technical Specification & Scope of Work'.

2

-

-

... More
Connecting the leads of 1.1 kV grade, 1C X 25 sqmm. unarmoured, stranded copper conductor cable, with MCCBs / MCBs / SDFUs/ Connectors [after finishing the ends by crimping method, including supplying & fixing solderless copper sockets , tapes, anticorrosive paste & jointing materials], at Distribution Board / Junction Box / SDFU, Motor terminal as per the 'Technical Specification & Scope of Work'.

16

-

-

... More
Providing Earthing Stations, using Earth Electrode [ made of 3 m long Medium Galvanised Mild Steel Tubes (as per IS:1239) of Nominal Bore 65 mm ] , including G.I. Funnel / Cap , Masonry Inspection Chamber with removable RCC Cover with handle, etc., as per the 'Technical Specification & Scope of Work'.

4

-

-

... More
Providing Earthing Stations, using Earth Electrode [made of 3 m long Medium Galvanised Mild Steel Tubes (as per IS:1239) of Nominal Bore 50 mm] , including G.I. Funnel / Cap , Masonry Inspection Chamber with removable RCC Cover with handle, etc., as per the 'Technical Specification & Scope of Work'.

4

-

-

... More
Providing G.I. Strip (Hot Dip) of size 50 mm X 6 mm, with G. I. Bolts, Nuts, Washers, etc., as required, for interconnection & Equipment earthing.

30

-

-

... More
Providing Earth Busbar of galvanized (Hot Dip) MS Flat [ 100 mm X 6 mm , 250 mm long] on wall , having clearance of 6 mm from wall, including providing drilled holes on the Busbar, complete with G. I. Bolts, Nuts, Washers, Spacing Insulators, etc., as required.

4

-

-

... More
Providing G.I. Strip (Hot Dip) of size 25 mm X 6 mm, with G. I. Bolts, Nuts, Washers, etc., as required, for Panel / Equipment earthing.

50

-

-

... More
Servicing of pumps for 3 years after DLP of 2 years Inspection, testing and submission of report the defect in details for the turbine water pumps with remedial measures.

6

-

-

... More
Withdrawal of the pump set / damaged pump set from the underground reservoirs with motor in full and reinstallation of the same after necessary repairs including bowl assembly, if required, as per Scope of work of the Tender Document.

3

-

-

... More
Repairing of the damaged pump set (Bowl assembly only) with necessary spares (Excluding cost of spares)

5

-

-

... More
Withdrawal of the motor from the pump set to replace the damaged stuffing box and reinstallation of the Motor all complete (excluding the cost of stuffing box etc)

4

-

-

... More
Withdrawal of the damaged motor from the tube well and replacement of the same with spare motor all complete. (Excluding supply and delivery of Spare motor).

4

-

-

... More
Replacement of the worn-out Head shaft of underground reservoirs pump set and reinstallation of the Pump and Motor all complete (excluding the cost of Head Shaft to be supplied at work site by HDC). The job includes cutting, threading and forming recess for key in the shaft (other than head shaft) if supplied by HDC.

4

-

-

... More
Opening out ratchet cover of the motor, cleaning of the ratchet pins thoroughly with petrol/ diesel and repositioning of the pins & ratchet cover, as per scope of work of the Tender Document. (The operation will be carried out for each pump generally once in a month)

72

-

-

... More
Decoupling of the damaged pump set from the foundation chassis and reinstallation of the same after necessary repairs to the pump set, as per scope of work of tender document including Checking of alignment of the shaft of motor & pump set by suitable instrument and correction of the same by providing necessary sims, as per scope of work of the Tender Document. Testing & trial run for not less than 15 minutes are to be carried out.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.