Kolkata Municipal Corporation Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Kolkata Municipal Corporation - KMC Tender
Electrical and Electronics
Eprocure
Opening Date15 Mar 2024
Closing Date16 Apr 2024
Tender Amount₹ 1,08,38,528
Costs
EMD
₹ 2,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KMC_685927_1Bid Award Id
ViewTender No
KMC/LTG/73/INST/46/VI/II/23-24Tender Authority
Kolkata Municipal Corporation ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
COMMON AREA DISTRIBUTION PANEL
Supply, Installation, testing & commissioning of the unit.
Incomer 1 : 1 no. 160A rated 4P MCCB (25KA) with O/L, S/C protection, rotary operating handle, pad locking arrangement.
Voltmeter with S/S.
3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp Main Busbar: 1 set 160A, TPN AL. busbars of suitable
length. Bus bars shall be colour coded and insulated
by PVC heat shrinkable sleeves . OUTGOING:
8 nos. 63A TP MCB (10KA)
9 nos. 32A TP MCB (10KA)
1 no. 40A TP MCB (10KA)
4 no. 32A SP MCB (10KA)
Complete panel ( MCCB Make :- L&T / Legrand / Schneider / Havells or Equivalent )
1
92000
92000
AC CHILLAR PUMP SYSTEM DISTRIBUTION PANEL-1 CUM FIRE HYDRANT SYSTEM PANEL
Supply, Installation, testing & commissioning of the unit. Incomer: 1 no. 200A rated 4P MCCB (25KA) with O/L, S/C protection, rotary operating handle, pad locking arrangement.
Voltmeter with S/S.
3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp Main Busbar: 1 set 200A, TPN AL. busbars of suitable
length. Bus bars shall be colour coded and insulated by PVC heat shrinkable sleeves . OUTGOING:
1 no. 200A 4P MCCB (25KA) 3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp
1 no. 200A 4P MCCB with shunt trip coil (25KA) 3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp Complete panel ( MCCB Make :- L&T / Legrand / Schneider / Havells or Equivalent )
1
138000
138000
AC CHILLAR PUMP SYSTEM DISTRIBUTION PANEL-2 CUM FIRE SPRINKLER SYSTEM PANEL
Supply, Installation, testing & commissioning of the unit. Incomer: 1 no. 200A rated 4P MCCB (25KA) with O/L, S/C protection, rotary operating handle, pad locking arrangement.
Voltmeter with S/S.
3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp Main Busbar: 1 set 200A, TPN AL. busbars of suitable
length. Bus bars shall be colour coded and insulated by PVC heat shrinkable sleeves . OUTGOING:
1 no. 200A 4P MCCB (25KA) 3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp
1 no. 200A 4P MCCB with shunt trip coil (25KA) 3 nos. phase indication lamps alongwith ON,OFF,TRIP Lamp
Complete panel ( MCCB Make :- L&T / Legrand / Schneider / Havells or Equivalent )
1
126600
126600
B) CABLES
-
-
-
Supply of Cable Supply of following 1.1 KV Grade XLPE/PVC insulated armoured Al. conductor cable of IS 1554 (Part - I).
( Make :- Polycab,KEI or Equivalent )
-
-
-
3.5 core x 300 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
150
368296
2455.31
3.5 core x 95 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
400
343200
858
3.5 core x 70 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
650
446160
686.4
4 core x 16 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
450
119691
265.98
4 core x 10 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
425
94507
222.37
4 core x 6 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
400
73788
184.47
4 core x 2.5 sq.mm 1.1 KV Grade XLPE insulated armoured Cu.conductor cable
100
28243
282.43
2 core x 4 sq.mm 1.1 KV Grade XLPE insulated armoured Cu.conductor cable
70
16516
235.95
Laying on Wall / surface with Saddles / clamps
-
-
-
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
70
3990
57
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
1375
82500
60
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
650
53950
83
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
400
34400
86
Laying on Wall / surface with Saddles / clamps
-
-
-
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
150
28050
187
Cable Termination : Compression Gland Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of
XLPE/PVC armoured cables as below :
-
-
-
3.5 core x 300 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
4
2068
517
3.5 core x 95 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
16
4384
274
3.5 core x 70 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
44
9328
212
4 core x 16 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
32
4224
132
4 core x 10 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
30
3960
132
4 core x 6 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
34
3910
115
4 core x 2.5 sq.mm 1.1 KV Grade XLPE insulated armoured Cu.conductor cable
8
2173
271.63
Finishing cable ends
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
-
-
-
3.5 core x 300 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
4
3528
882
3.5 core x 95 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
16
4960
310
3.5 core x 70 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
44
11572
263
4 core x 16 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
32
3040
95
4 core x 10 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
30
2010
67
4 core x 6 sq.mm 1.1 KV Grade XLPE insulated armoured Al.conductor cable
34
2108
62
4 core x 2.5 sq.mm 1.1 KV Grade XLPE insulated armoured Cu.conductor cable
8
448
56
Finishing Copper Wire ends Finishing of the PVC insulated wire ends by socketting with pin/
ring type copper sockets and insulated tapes etc., including
supplying sockets, tapes
-
-
-
2 core x 4 sq.mm 1.1 KV Grade XLPE insulated armoured Cu.conductor cable
4
28
7
C) LIGHTING ARRESTOR EQUIPMENTS :
-
-
-
Supply installation testing of Surge Lightning Arrester conforms to NFC 17-102-2011. This provides an enhanced 30 mtr. Radius protection, reducing the number of Lightning Arresters and down conductors needed for your structure.
Complying Standard: NFC 17-102 Body of Device: Copper Alloy Tested At: 200KA
ΔT: Advanced Triggering Delta T 60µs
With respect to mast height 5meter, ASLA 60 willl cover 60m Radius of protection at Level 4 protection.
1
45000
45000
Supply installation testing of GI Mast for 5 Meter Height with Guy Wire and accessories
1
12500
12500
Supply installation testing of Digital Lightning Strike Counter-6 digit- digital with IP 67 Protection.
6
45000
7500
Supply installation testing of Down Conductor with fixing arrangement & others acessories: 70Sqmm flexy copper cable.
50
42500
850
Supply installation testing of Maintenance Free Earthing with:
1. UL certfied 17.2 mm dia 3000mm long 250 Micron copper bonded rod.
2. Brass Connection Clamp.
3. Earthing Chemical-50 Kg
4. 300mm*300mm HDPE earthing pit chembar with 5000kg load capacity.
6
49200
8200
D) D.G SET:
-
-
-
Supply, installation, comissioning & testing of 400 KVA SILENT D.G. SET consists of RADIATOR COOLED coupled with 415V 400 KVA, AMF controller mounted on a common base frame along with other standard accessories i.e. residential silencer, batteries with leads, fuel tank, AVM pads enclosed in CBCB - II approved acoustic enclosure including transportation up to site except unloading with isolator panel (Including full fuel as per tank capacity) (Make :- Sterling / kirloskar or Equivalent )
1
4618400
4618400
C) EXTERNAL ELECTRICAL WIRING:
-
-
-
Supplying and fixing MCCB SS enclosure with IP 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachmen(4 WAY) (MCCB Enclosure Make :- Legrand / L&T / Schneider / Havells or Equivalent)
5
6110
1222
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and
necessary connection (MCCB Make :- Legrand / L&T / Schneider / Havells or Equivalent) 160A 4P MCCB
2
14584
7292
200A 4P MCCB
3
30054
10018
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. ( MCB Make :- Legrand / L&T / Schneider / Havells or Equivalent)
4 Way
11
3476
316
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (MCB Make :- Legrand / L&T / Schneider / Havells or Equivalent) 63A 4P MCB
3
4575
1525
40A 4P MCB
5
5230
1046
32A 4P MCB
3
3138
1046
Earthing :
-
-
-
Earthing Installation – with CU Plate Earthing : Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
4
41864
10466
Earthing Installation – with GI Pipe Earthing : Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts.
long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20
mm dia x 125 mm long galvanized bolt, double nuts, double
washers including socketing at both ends of stranded GI (Hot
Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia
GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with
bitumen partly under the ground level and partly above ground
level to an average depth of 3.65 Mts
6
18876
3146
Earthing connection from earth electrode to Equipment Neutral : Extra for connecting the neutral of Transformer/Earth busbar to earth electrode including S & F 50 mm x 6 mm Galvanized (Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape.
60
13440
224
Equipment earthing : Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
60
11880
198
Earth Continuity Conductor : Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
10 SWG GI Wire
200
1200
6
GI Pipe Protection
Supplying & fixing medium gauge GI Pipe ( ISI-Medium)
Protection with necessary fittings and jointing metarials as
required 150 mm dia
50
56850
1137
Laying through RCC/Hume/GI Pipe Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
180
7740
43