Kolkata Municipal Corporation Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Kolkata Municipal Corporation - KMC Tender

Works
Civil And Construction
Eprocure
Opening Date5 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 1,77,024 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Carriage of CI / Dl / ERWMS / AC pipes including loading into truck at the lifting point, unloading at destination and stacking properly in godown or yard etc. as directed (Including carriage by head load upto 30 metres at each of the two points. The rate covers all the above operations, actual transport all complete.diameter in mm 100 per km beyond 10km to 20km

17.6

281

16

... More
Carriage of CI / Dl / ERWMS / AC pipes including loading into truck at the lifting point, unloading at destination and stacking properly in godown or yard etc. as directed (Including carriage by head load upto 30 metres at each of the two points. The rate covers all the above operations, actual transport all complete.diameter in mm 100 per km beyond 20km

40.48

526

13

... More
Manufacturing and. supplying M.S. Saddle with 10mm thick M.S. pipe, 25mm thick M.S. Flange including fabrication true to size with M.S. clamp, drilling hole on angle/ flat, gas cutting and welding etc. complete. 12in /4in dia

1

11483

11483

... More
Supplying including cost of installation of C.I. Mechanical joint Tee as dimensionally described in IS:13382/2004. Each Tee consists of One C.I. Body, Two C.I. Follower Glands, Two sealing Rubber Gaskets of EPDM quality (Conforming to IS:5382/1985 Type-4) and Zinc coated M.S. Fasteners. The Branch Flange is drilled as per IS: 1538. The whole assembly is mechanically and hydraulically tested to provisions as laid down in IS: 13382/2004.Diameter in mm 150 x 150 x 100

2

12270

6135

... More
Cost iron double flanged manually operated sluice valves generally conforming to IS 14846 : 2000, having four faces and spindle nut of gunmetal. inside screw non- rising type quality gunmetal /AISI 410 spindle: seat tested to 10kg/CM... and body tested to 15kg/CM..., flanges flat faced and drilled to 1.S.: 1538 : 1993. Painted black all over with asphalt base paint. Valves tested by closed end method. NB Diameter in mm 100

2

10134

5067

... More
All types of Ductile Iron (D.I) Specials (viz. Bend. Tee. Taper. Tail piece etc), size conforming to I.S. Specification No. 9523/2000 with cement mortar lining (inside) and bituminous coating (outside). (25% of payment will be held up till successful hydraulic testing)c) Tail Piece 100 mm to 300mm dia.

20

2880

144

... More
All types of Ductile Iron (D.I) Specials (viz. Bend. Tee. Taper. Tail piece etc), size conforming to I.S. Specification No. 9523/2000 with cement mortar lining (inside) and bituminous coating (outside). (25% of payment will be held up till successful hydraulic testing) b) Doubled Socketed Bend 100 mm to 300mm dia

84

10500

125

... More
All types of Ductile Iron (D.I) Specials (viz. Bend. Tee. Taper. Tail piece etc), size conforming to I.S. Specification No. 9523/2000 with cement mortar lining (inside) and bituminous coating (outside). (25% of payment will be held up till successful hydraulic testing) a) All Socket Tee 100 mm to 300mm dia.

30

3840

128

... More
Supplying, fitting and fixing of C.I. Mechanical Compression flexible Collar Couplings suitable for C.I. Spun Pipes (as per IS: 1536) and D. I. Pipes (as per IS: 8329) complete with Sealing Rubber Gasket of EPDM quality (IS:5382/1985 Type - 4), Cast Iron Follower Glands and Mild Steel Nut Bolts (Zinc Coated). The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538. Fitting and fixing should be in proper position with proper care of main pipe line for leak proof condition. Diameter in mm 100

2

3300

1650

... More
Supply of Single/Double bit SBR gasket suitable for jointing CI/DI pressure pipes, conforming to IS : 5382 : 1985 [Popularly known as `Tyton Gasket...] 100mm dia

54

2106

39

... More
Excavation of trial pit (3.0 m x 1.0 m x (upto) 3.0 m) for fixing of pumping main, washout line raking every detection against damage of S.W. pipe line electrical cable etc. as underground obstruction including 37.5 mm timber shuttering, earth cutting, dewatering, barricading and back filling etc. as per directionj of E-I-C

3

5601

1867

... More
Hire and labour charges for 75 mm dia bamboo railing on Jhau/Eucalyptusor other approved timber\bamboo posts 1.4 m above G.L and 0.60 m below G.L including tying strongly with coir ropes and boring holes for posts in any soil/ concrete surface/Bituminious surface packing the sides etc including cost of carriage of all materials and labour complete including cost of restoration to the damages of the ground to its original condition as per direction of Engineer in charge after removing the barricade.(Cost of restoration would be paid seperately. a) 75mm. dia bamboo railing & 125mm. Dia Jhau/Eucalyptus/other approved timber posts @ 1.60m apart (ii) Railing with 3 rows.

16.8

823

49

... More
Hire and labour charges for coloured and twisted cloth rope fencing as per design approved by Engineer-in-charge one line with 100 mm dia Eucalyptus or bamboo posts 0.60 m above G.L and 300 mm below G.L 1.50 m apart fitted and fixed complete including painting with white zinc painting (2 coat) complete.Payment of painting to be made seperately.

176

3520

20

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

0.94

11193

11927

... More
Dewatering by pumps including all leads, lifts and making all arrangements of disposal. where continuous flow of water from a source other than natural or ground water is encountered in case of emergency maintenance works related to leakage. breakage and making wet connections. [Note ;- In case of any other situation demanding such emergency dewatering. use of this item is to be approved by the Superintending Engineer/Tender Accepting Authority. This item shall be executed on the specific direction duly supported by proper clarification of the E.I.C. who will be satisfied in absolute discretion that such work has not been necessitated due to any natural source of water or any fault of the Contractor]

50

1650

33

... More
Hire & labour charges for diesel generating set for lighting including fuel,300M wire, 11 points with 200 Watt bulb with post for hanging & maintaining the same for day & night for the period.

2

3300

1650

... More
Wet connection with M.S. saddle on running mains by drilling with electric drill. plugging with wooden plug. using nuts and bolts. rubber insertion.dewatering trenches all complete excluding cost of M.S. saddle & Earthwork. 12in /4in dia

1

16330

16330

... More
Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane(for diameter above 250 mm) by providing temporary support,as required,gaskets,nuts& bolts etc.all cornplete as per specification and direction of the Engineer-in-Charge.[The rate Includes cost of flange joints]50mm dia.

2

1972

986

... More
Lowering any type of Ductile Iron (DI) pipes & specials and laying along trench at any depth as per speclfication and direction of the Engineer-incharge, ( laying over ground. the rates shall be, reduced by 10% and the rates so reduced shall be inclusive of cost of all sorts of holding arrangements]Diameter in mm 100mm dia.

1.76

2464

1400

... More
Cutting of C.l/D.I pipes for fitting with pipes and-or specials of similar or dissimilar materials at the time of laying without damaging any part of the required length including taking out of the broken pieces from the trench and restacking the same at the specified location as per direction of the Engineer-in-Charge.D iameter in mm 150mm dia.

2

252

126

... More
Cutting of C.l/D.I pipes for fitting with pipes and-or specials of similar or dissimilar materials at the time of laying without damaging any part of the required length including taking out of the broken pieces from the trench and restacking the same at the specified location as per direction of the Engineer-in-Charge.D iameter in mm 100mm dia.

12

1092

91

... More
Chamfering the spigot end of C.l./D,l. pipes for fitting with the socket of C.I./D.I pipes and/or specials in tyton jointed water mains or other wise using electric grinder as per specification and direction of the Engineer-in-Charge. Diameter in mm 150mm dia.

2

226

113

... More
Chamfering the spigot end of C.l./D,l. pipes for fitting with the socket of C.I./D.I pipes and/or specials in tyton jointed water mains or other wise using electric grinder as per specification and direction of the Engineer-in-Charge. Diameter in mm 100mm dia.

24

1776

74

... More
Rubber gasket joints to C.l./D.l. pipes and specials all complete to makesthe joint water tight as required hydraulic pressure as per specification and direction of the Engineer-in-Charge.[Cost of Rubber. gasket of approved make induding supply to any pointwithin the Kolkata Municipal Area shall be paid separately.}Diameter in mm 100mm dia.

54

3186

59

... More
Shifting house connection or stand post connection from existing main to new main after excavation through any kind of soil and road materials up to required depth. dismantling existing ferrule with all fittings. plugging hole of old main with G.I. plug. drilling and tapping the new main. refixing the ferrule on the new main with serviceable old G.I pipes and other specials (New G.l. pipes and other specials. if required to be installed shall be paid extra) and back filling the trench with excavated materials all complete as per specification and direction of the Engineer- in-Charge.

11

15697

1427

... More
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (ii) 20 mm dia. medium quality

19.8

4752

240

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992.(A)(iii) Single Socketed 1.8 Metre Length.(b) 110 mm

9

2637

293

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials.(B) Under ground.(ii) 110 mm dia.

9

756

84

... More
Hydraulically testing of C.l./D.I/A.C pipe lines in sections, under a head of water not less than 60m{6Kg/Cm....pressure) or above as per specific requirements by filling the main with supply of water including supply of all specials and equipments like pump sets, gauges, end caps blank flange etc.all complete as per specification and direction of the Engineer-in-Charge.[After successful completion of test. removal of ancillary specials.equipments. plugging arrangements and disposal of water sholl be made at no extra cost] Diameter in mm 100

1.76

3833

2178

... More
Disinfection of water main by filling with water containing bleaching powder of sufficient quantity capable of maintaining a residual chlorine concentration of 10mg/l within the main after a detention period of two hours and flushing the same with fresh water all complete as per specification and direction of the Engineer-in- Charge.[After successful completion of the process, disposal of water and bacteriological testing of sample of flushed out water from the mains should be made at no extra cost] Diameter in mm 100

1.76

1446

822

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.(Payment to be made based on the basis of measurement of finished quantity of work.(a) With earth obtained from excavation of foundation

0.89

6895

7754

... More
Removal of rubbish, earth etc. from the working site and disposal of thesame beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning thesite in all respect as per direction of Engineer in charge.

1.99

330

166

... More
Sub Total

-

-

-

... More
GST 18%

1

26736

26736

... More
CESS 1%

1

1752

1752.72



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.