Kolkata Metropolitan Development Authority Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Kolkata Metropolitan Development Authority - KMDA Tender

Works
Civil And Construction
Electrical Goods and Equipments
Machinery and Tools
Electrical and Electronics
Eprocure
Opening Date11 Apr 2025
Closing Date6 May 2025
Tender Amount₹ 3,45,98,245 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder includes completion certificates for fully completed works during the last five financial years. Partly completed works valued more than the estimated cost of this tender will also be considered. The value of similar works completed is not explicitly mentioned, but it is stated that partly completed works valued more than the estimated cost of the tender will be considered. No specific amount is mentioned for similar works completed, but a credit worthiness certificate/Bank Solvency of not less than 20% of the estimated value put to tender is required.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, delivery , storage and installation at site of MS pipes, specials, joints, flanges as per specification and Technical offer. (for both individual pump delivery pipe and extended part of common manifold if required) .

1

-

1260000

... More
Supply, delivery and installation and commissioning of valves complete at site with fixture as per specification and Technical offer & as follows :-

-

-

-

... More
DI Butterfly valve for delivery side of pump fitted with electrical actuator suitable for local and control desk operation and display system for the individual pump delivery pipe line. (350 mm minimum))(PN 16 type)

1

-

447595.01

... More
DI Non-Return Valve for individual pump delivery pipe line. (350 mm. minimum))(PN 16 type)

1

-

527226.47

... More
Supply, delivery at site and storage of M.S. dismantling joint assembly for the individual pump delivery pipe line as per specification (350 mm minimum).

1

-

130200

... More
Supply, delivery ,storage and installation at site of Pressure gauges complete with fittings and fixture as per specification

-

-

-

... More
Pressure gauge for Delivery side (0– 10 Kg / cm2)

1

-

35700

... More
Supply, delivery ,storage and installation at site of pressure transmitter complete with fitting and fixture as per specification as follows:-

-

-

-

... More
Pressure transmitter for delivery side ( 0 – 10 Kg / cm2 )

1

-

67200

... More
Supply, delivery at site and installation of M.S. Structural materials for cable tray / rack, panel installation supports, Pipes & valves supports, fabricated stairs & all other fabrication work.

1

-

252000

... More
LT Panel

-

-

-

... More
Modification / retrofitting/expansion/addition of the existing PMCC with supply , delivery & installation of a new additional motor starter feeder at RWPH in order to accomodate the extra pump-motor feeder of requisite rating not less than 110 KW .The modification/addition should match/synchonise the existing panel and should ensure smooth operation of the complete panel as a single entity and should be fit to install at the existing pump house.

1

-

1053080.6

... More
Retrofitting of existing Control Desk at site with supply,wiring, installation of additional items like Temparature Scanner , Multifunction meter , Microprocessor Based Position Indicator, Digital Pressure Indicator,TNC switch, push button switch, indication lamps etc .as required to complete for the new Pump motor set.

1

-

223668.5

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size from Motor feeder to Motor .(Min. 2 Run x 3Core , 185 sq mm XLPE Armoured AL. for each feeder)

1

-

463191.3

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size and length from PMCC to Motor Space Heater . (Min. 3 Core 2.5sq mm. Armoured CU for each motor)

1

-

33663.3

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size and length from PMCC to Valve Actuator etc. elsewhere required. (Min . 4 Core 2.5 sq mm. Armoured CU)

1

-

41003.6

... More
Making end termination of all the Power Cables as stated in sl no 11,12,13 with all necessary equipments like termination kits(Dry type), lugs , glands etc , installed for the modification job.

1

-

31697.6

... More
Supply ,delivery, Laying, installation of Control Cables of different size as required for the purpose and length for completing the different control connections between Control Desk, Motor feeders , LPBS, PMCC etc.to the satisfaction of the EIC for completion of the entire scheme and smooth operation.

1

-

31697.6

... More
Supply ,delivery, Laying, installation of Signal Cables of different size as required for the purpose and length for completing the different Signal connections to the satisfaction of the EIC for completion of the entire scheme and smooth operation.

1

-

584684.1

... More
Making end termination of all the Control/ Signal Cables as stated in sl no 15 and 16 with supplying all necessary equipments like termination kits,lugs , glands etc , installed for the modification job.

1

-

30212.6

... More
Supply, Installation, testing and commissioning of new Heavy Duty Box type capacitors of adequate rating replacing the faulty Capacitor Banks of the RWPH PMCC as per site requirement and to achive power factor 0.98 lag .

1

-

82471.4

... More
Civil Modification of the MCC Panel Room with re-orientation of Aluminium glass Door along with minor civil works including reorientation of stairs as necessary for modification the job to complete.

1

-

272580

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

40

-

7760

... More
For CWPS

-

-

-

... More
Supply, delivery , storage, installation, testing & commissioning of horizontal axially split case type Centrifugal Pump of 760m³/hr discharge at a Head of 52 mtr at duty point with horizontal squirrel cage TEFC motor rated at 415 V ± 10%, 50 Hz ± 5% , 3 phase 1500 RPM (syn) of adequate capacity to match the pump complete with coupling hub and all other accessories as required and as per technical specification . (Rating of motor shall not be less than 160 KW).

2

-

4586722.56

... More
Supply, delivery , storage and installation at site of MS pipes, specials, joints, reducer/enlarger, flanges, supports etc. to complete the job as per specification and direction of the EIC . (for both individual pump delivery pipe and extended part of common manifold ) .

1

-

1260000

... More
Supply, delivery at site & installation of valves complete with fixture as per specification and Technical offer & as follows :-

-

-

-

... More
DI Non-Rising Sluice valve for individual suction side of pump.(400 mm minimum))(PN 16 type)

2

-

669846

... More
DI Butterfly valve for delivery side of pump fitted with electrical actuator suitable for local and control desk operation and display system for the individual pump delivery pipe line.(350 mm minimum))(PN 16 type)

2

-

891510

... More
DI Non-Return Valve for individual pump delivery pipe line.(350 mm. minimum))(PN 16 type)

2

-

1050118

... More
Double throat air valve with Isolating Valve at pump delivery line as per specification (100 mm)

1

-

68250

... More
Supply, delivery at site and storage of M.S. dismantling joint assembly for the individual pump delivery and suction pipe lines as per specification & direction of the EIC .(350 mm minimum)

2

-

260400

... More
Supply, delivery ,storage and installation at site of Pressure gauges complete with fittings and fixture as per specification :-

-

-

-

... More
Pressure gauge for Delivery side (0– 10 Kg / cm2)

2

-

71400

... More
Supply, delivery ,storage and installation at site of pressure transmitter complete with fitting and fixture as per specification as follows.

-

-

-

... More
Pressure transmitter for delivery side ( 0 – 10 Kg / cm2 )

2

-

134400

... More
Supply, delivery at site and storage of M.S. Structural materials for cable tray / rack, panel installation supports, Pipes & valves supports, fabricated stairs & all other fabrication work as required. (For two pump motors).

2

-

409500

... More
LT Panel

-

-

-

... More
Modification/Servicing & retrofitting of the 2 Nos. Motor Starter feeder including all components like Contactors , MCCB etc. calibration and checking of the microprocessor based Motor Protection relay and making all required modification to make the starter feeder capable of smooth running & synchronization of the proposed Clear Water Pumps with respective feeder to complete and as per direction of EIC . (Necessary Spares shall be supplied and installed if required ).

1

-

126555

... More
Checking of the control circuit of the LT Panel and Control Desk and re-calibration of all the equipments concerned after successful connection of all the signal and control cables required for the modification and smooth running & synchronization of the proposed Clear Water Pumps with respective feeder to complete and as per direction of EIC . (Necessary Spares shall be supplied and installed if required).

1

-

42185

... More
Supply, Installation, testing and commissioning of new Heavy Duty Box type capacitors of adequate rating replacing the faulty Capacitor Banks of the CWPH PMCC and MV Panel at sub station as per site requirement to achive P.F.-0.98 lag .

1

-

85213.7

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size and length from LT PMCC Motor feeder to newly installed Motors . (each min. 2 Run, 3 core, 185 sq mm XLPE Armoured AL.) x 2 Set. motors

1

-

1764760.8

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size and length from LT PMCC to Motor Space Heater. (each min. 3 Core 2.5sq mm. Armoured CU) x 2 Set.

1

-

134654.3

... More
Supply ,delivery, Laying, installation of Power Cable of adequate size and length from LT PMCC to Valve Actuators . (each min . 4 Core 2.5 sq mm. Armoured CU) x 2 set

1

-

328031

... More
Supply , delivery, Laying, installation of additional Power Cable of adequate size and length from Substation PDB Outgoing feeder to pump house MCC Incomer. (each 2 Run, 3.5 Core, 300 sq mm, XLPE, Armoured AL.) x 2 set. ( for 2 nos.incomer of pump house)

1

-

3727582

... More
Making end termination of all the Power Cables given in sl no 31, 32,33,34 with with supplying all necessary equipments like termination kits (Dry type), lugs , glands etc , installed for the modification job.

1

-

91128.4

... More
Supply ,delivery, Laying, installation of armoured copper Control Cables of adequet size as required for the purpose and adequate length for completing the different control connections between Control Desk, Motor feeders , LPBS, PMCC etc.to the satisfaction of the EIC for completion of the entire scheme and smooth operation.

1

-

763801.5

... More
Supply ,delivery, Laying, installation of armoured copper Signal Cables of different size as required for the purpose and adequate length for completing the different Signal connections to the satisfaction of the EIC for completion of the entire scheme and smooth operation.

1

-

2338736.4

... More
Making end termination of all the Control/ Signal Cables givenin Point No: 36, 37 with all necessary equipments like termination kits (dry type), lugs , glands etc , installed for the modification job.

1

-

82682.6

... More
Supply, delivery, installation at site of GI Cable tray (Ladder Type) min. 300 mm or higher size for smooth laying the cables for both RWPS and CWPS .

1

-

649649

... More
Supply, delivery, installation at site of GI Cable tray (Perforated) MIN. 300 mm or higher size for smooth laying the cables for both RWPS and CWPS .

1

-

275721.6

... More
Supply, delivery, installation at site of Supports and fixture required for Hanging and laying of the above cable trays for both RWPS and CWPS .

1

-

287212.2

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required along with earthing arrangement of three (03) nos. motors as per IE rules and specification . (for 1 no. motor at RWPS and 2 nos. motors at CWPS )

150

-

29100

... More
Supply ,delivery ,laying of RCC Spun pipe /heavy duty PVC/HDPE Pipe of adequate dia and length in pre excavated trench required for road crossing of cables at CWPS . (Excavation and mending good of damages are included within scope of this item).

1

-

93456

... More
Painting and Testing, Commissioning of the whole installation including trial run for three months on load operation as per specification & direction of EIC for both RWPS & CWPS .

1

-

265760

... More
N.B :- No extra payment would be made if the length and diameter of the different sizes of cable & joints varies on the higher side to meet up the requirement of the specification and site condition. Rates must be quoted carefully. This is also applicable for all type of cable joints.Visit of actual site is advisable before quotting for the job.The rates quoted are non-exhaustive and will include the entire electrical job required to fullfill the smooth operation of the plants post modification.

-

-

-

... More
Added:- @ 1% as labour cess

1

-

342556.86



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.