Kolkata Metropolitan Development Authority Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Kolkata Metropolitan Development Authority - KMDA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 Jan 2025
Closing Date28 Jan 2025
Tender Amount₹ 3,54,193 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Preliminary cheching and testing and of IR value, insulation leakage of startor, cracks of porcelin bushing, conn. Terminal leads, fibre glass terminal blocks and rotor end ring joints etc, before to detect the fault for 3.3KV/ 3.3KV sq. cage induction motor.

1

11239

11239

... More
Blow off the dust and dirt from the winding and ventilation duct by dry compressed air at a pressure of about 2 Kg/ cm2 as directed by the EIC.

1

2761

2761.9

... More
Cleaning of the winding with dry cambric cloth if found the winding oily/ greasy surface, then clean with wet cambric cloth soaked in trichloroethylene or carbon tetra choloride as directed by the EIC.

1

7809

7809.52

... More
Heat varnishing the stator winding by DR. Beck class F varnish and also finishing the surface with Dobeckor and hardner 520 F hardner compound with appropriate proportion so that it can withstand temparature as specified for class F and IS 325 as directed by EIC.

1

64476

64476.19

... More
Checking of bracing ring on overhang winding if found loose tighten it by retaping as per direction of EIC.

1

2761

2761.9

... More
Checking all the mouth block and packing pieces are in position as per direction of EIC.

1

1619

1619.05

... More
Checking the contacts at the terminals and earthing points, clean throughly if required.

1

1428

1428.57

... More
S & F of 4m length of 95sqmm/ 3.3kv/ 6.6 kv grade HT glass copper leads with end finishing by 95 sq.mm. heavy duty dowells copper lug at STAR conn. Terminal leads including replacement of Glass fibre terminal block and SS bolts etc.

1

16504

16504

... More
Carring out of replacement work of worn out bearing by new bearing no 7224B (NDE) by heat shirnk method as directed by EIC.

1

50761

50761.9

... More
Carring out of replacement work of worn out bearing by new bearing no NU228 (DE) by heat shirnk method as directed by EIC.

1

54076

54076.2

... More
Greasing the DE and NDE bearing by Lithium base grease type IOC Servogem 3 ( No deviation will be allowed in this case.)

1

4380

4380.95

... More
Reassembling all component with great care as directed bt the EIC

1

18095

18095.24

... More
Inserting the rotor inside the stator very carefully & so caustiously that in any case does not rub with stator as directed by EIC.

1

12476

12476.19

... More
Properly checking, testing of developed IR value of the motor, leakage factor of bushings, terminal shirtings, IR value of G.F. blocks etc. after the necessary repaing works for 3.3KV/ 6.6 Kv sq. cage induction motor.

1

11265

11265

... More
Painting of the motor unit with epoxy based paint as per direction of EIC.

1

5904

5904.76

... More
Box up the total motor unit with connecting the bearing temperature detector and conforming its fuction as directed by EIC.

1

4571

4571.43

... More
Charges for return back of the HT motor from workshop to pum phouse including loading unloading charge and other as directed by the EIC.

1

5714

5714.29

... More
Added GST @ 18%

1

53494

53494.51

... More
Added:- @ 1% as labour cess

1

3506

3506.86



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.