Kolkata Metropolitan Development Authority Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Kolkata Metropolitan Development Authority - KMDA Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Sep 2022
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 19,312Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KMDA_404299_2Bid Award Id
ViewTender No
KMDA/EM/EE/ED-II/NIT-26/22-23Tender Authority
Kolkata Metropolitan Development Authority ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Single arm bracket(exceeding 1.5M but not exceeding 3M.
2
-
42.9
Fixing of bracket arms of length as given below suitable for steel tubular pole having outside dia.upto 115mm including S & F GI nuts, bolts, washers etc.as required and making necessary holes as required as directed by EIC
-
-
-
1.5m but not exceeding 3.0mtr. Single arm bracket.
2
-
53.62
Removing of luminaries with lamps from the pole/column and keeping them ready for despatch as per direction of EIC & Hoisting, fixing and commissioning of luminaries incl making necessary connections & earthing attachement.
2
-
122.52
Dismantling of OH line comprising of copper/AAC/ACSRconductor, cross arms / ‘D’ iron clamps / brackets / ‘V’ brackets
etc. insulators, earthwire, cradle guard, safety devices, staywireetc., incl. sorting out, rolling the conductors, stacking, loading atsite and delivering, unloading , measuring the conductors,sorting, stacking properly at any place as per direction upto alead of 1.6 km
-
-
-
OH line comprising of 3 phase, neutral, street light phase & earth wire
2
-
601
Supply, Delivery of 11 Mtr Swaged Type Steel Tubular Pole Non- Slotted (410SP-53) having dimension overall length 11mtr bottom-165.1x4.85mm, middle-139.7x4.5mm & top- 114x3.65mm incl carriage of pole from workshop to site as per direction f EIC.
12
-
15888
S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of Each 1058.00 1. 5 m (5’) length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps, etc. as required with fabrication.
-
-
-
1500mm long with 48.8 OD MS Pipe single arm
12
-
1058
2000mmlong with 48.8 OD MS Pipe single arm
4
-
2534
2000mmlong with 48.8 OD MS Pipe double arm180 degree
3
-
4002
Erection of Single Steel tubular pole of length as given belowwith/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600 x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. above 9.0 mtr.
12
-
3355
Supply & Delivery of 1100 volt Grade PVC/XLPE insulated un-armoured aluminium conductor cables of following sizes.
-
-
-
4Cx16Sq mm unarmoured.
325
-
230
Erection of PVC/XLPE insulated aluminium conductor cable upto 4 core 16 Sq.mm by catenary system incl S&F of 1 no 6 SWG GI wire, porcelain reel insulator (3x3.5'), hexagonal galvanised bolts & nuts incl painting complete as per direction of EIC.
325
-
54
S & F & replacement of cable core termination special head at the pole top with necessary GI nuts, bolts, washers etc.as per required complete as per drawing and direction of the EIC.
12
-
424
Supplying Fixing bakelite cable core termination block inside pole slot/loop-in box including making necessary connections as per direction of EIC.
12
-
142
Supplying & Erection of Galv. ‘D’ iron complete with suitable pole clamp 100mmx114mm porcelain shackle insulator & 19 mm dia Galv. bolts & nuts. incl. painting.
12
-
133
S&D of 5/8 tene screw arrangement at pole clamp for fastening arrangement of catenary
24
-
56.7
Supplying cable socket(lug) and making core termination including soldering/ crimping etc. suitable for the following PVC insulated AL/CU conductor as required including making connection (cable socket made of aluminium) i)4Cx16Sq mm cable.
24
-
95
Supply and wiring in 2x1.5Sq mm Cu conductor single core PVC insulated 250V grade wire from cable termination block to luminaires with earthing attachment in 14 SWG GI wire including making necessary connection com- plete as per direction of the EIC.
50
-
34
Supply, Delivery, Hoisting & fixing of suitable LED fitting 27800 lumen output complete in all respect .(make- Philips or eqivalent).
28
-
15906
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projectedfrom the wall of the building incl. making holes/providing clamping arrang- ement & necy. GI reducer as required. S&F 40 mm GI pipe(ISI-Medium) quality 1.5 mts. average length having suitable bendS&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required andmending good damages to wall incl. painting etc.
3
-
807
Earthing with 50mm dia GI Pipe 3.64mm thick x3.04mtr.long and 1x4 SWG GI (Hot Dip) wire (4mtr.long) 13mmx80mm long GI bolts, doub- le nuts, double washers including S & F 15- mm dia GI pipe protection (1mtr.long) to be fil- led with bitumen partly under ground level and partly above the ground level driven to an ave. depth of 3.65mtr.below the ground level and restoring surface duly rammed as below. i)ISI-Medium GI pipe
12
-
1369
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary. Without Loop Box
7
-
1134
Add : GST@ 12.00%
1
-
102430.31
Add CESS @ 1.00%
1
-
9560.16
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements