Kolkata Metropolitan Development Authority Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Kolkata Metropolitan Development Authority - KMDA Tender
Machinery and Tools
Eprocure
Opening Date19 Jul 2024
Closing Date3 Aug 2024
Tender AmountRefer Documents
Costs
EMD
₹ 32,517Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KMDA_713689_1Bid Award Id
ViewTender No
EE(E/M)/JNNURM-I/KMDA /2W-05/2024-25/205Tender Authority
Kolkata Metropolitan Development Authority ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
S & D of Submersible Copper cable of 3 core 6 sq mm 1100 V grade.
148
-
-
C.I sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gun metal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed completed. size-150 mm.
2
-
-
CI doble flange type NRV face to face IS 5312 hinge pin SS 410 driling IS 1538 pressure rating PN 1.0
4
-
-
Supply of all types of CI specials viz bend, tee, tapper, tail piece, collars, bell mouth, with puddle collar etc as per specification. CI plain end IS 5531.
-
-
-
a D & F 150 mm dia 90 bend
4
-
-
b All end flanged 150 x 150 x 150 CI T -Piece
2
-
-
Supply, Delivery & Installation of 415 V, 3 Phase, 50 hz Auto-manual 20 KW Star-Delta starter Control Panel for Sub. P/M Set.
2
-
-
Supplying of following XLPE industrial aluminum conductor armored cables of 1.1KV grade as per IS 7098 (Part1) 1988 with upto date amendments. 3.5 core 35 sqmm.
36
-
-
Supply of HT rubber mat of size 3' x 6'.
36
-
-
Supply & delivery of 1200 mm sweep A.C Ceiling Fan without regulator with all accessories.
2
-
-
Supply and fitting of smart bright street light (36watt) complete with all accessories to be fixed/projected from the wall of the building or on pole including making holes/providing clamping arrangement & necessary GI reducer as required. S&F 40mm GI pipe (ISI-Medium) quality1.5mts. average length having suitable bend S&F necy. length1.5sqmm PVC insulated single core standard annealed copper wire and making connection as required and mending good damaged to wall incl. painting etc. make Philips
2
-
-
Supply TMC 501 conventional industrial batten Philips LED modelno. TMC 501P 2 x T-LED 22W P3242
2
-
-
Supply, delivery, installation, testing & commissioning of suitable 415V, 3 phase, 50 Hz, 30/40 kva voltage stabilizer(Air cooled) with U/V, O/V, O/L, protection .voltage range 200-500V
2
-
-
Supplying and fixing changover switch with sheet steel encloser on angle iron frame on wall with nuts bolts etc. 100Amps, make Havels.
2
-
-
S & F MS top clamp 12 x 80 mm section for Sub P/M Set in two halves.
4
-
-
S & F of safety clamp for the P/M Set 6 mm x 40 mm section.
2
-
-
S & F of pressure gauge of range 0-200 sq in with cock.
2
-
-
Split type M.S fabricated suitable tube well cover for the tube well non-sign with necessary damping arrangement including holes for column pipe, air pipe & cable entry.
2
-
-
Construction of supporting pillar supporting platform for the resting of valves for easy operation with neat cement finish as per direction of EIC.
2
-
-
S & F of CI double flanged pipe fitting 1 no 150 mm.
30
-
-
Supply, painting best quality weather thermal resistance paint appv quality two coats with necessary smoothening of surface and application primer incl material, labour and hire charge of tools & plants etc all complete.
6
-
-
S & F of protecting device comprising of wire rope clamps etc.
2
-
-
Flange joint to CI/DI/MS pipes and specials incl supply of rubber gasket, nuts,bolts,washers etc of quality to make the joint water tight as reqd hydraulic pressure and direction of EIC.
12
-
-
Installation of pumping machinery with valves, pipe & pipe specials short piece, depth gauge, pressure gauge including hoisting of column pipe, making all electrical and water line inter-connection complete as per direction including supply of necessary materials as reqd. for the work.
2
-
-
Supplying and fixing sheet steel main switch on angle iron frame on wall 125 /150 amp 415 V TPN with fuse on L & N Make-Havells/ Flora.
2
-
-
Supplying and fixing sheet steel main switch on flat iron frame on wall 15/16 amp, 240 V DP with fuse on L & N Make-Havells/Flora.
2
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC cable for 3 1/2 core upto 35 sq mm.
14
-
-
Finishing end of XLPE/PVC armoured cables by crimping method incl. Supplying fixing solderless socket(dowels make), tapes, anti corrosive paste & jointing materials 35 sq mm 3.1/2 core.
14
-
-
Laying of two cables upto 35 sq mm in underground trench in single tire formation (horizontal) the trench size 680 mmx 760 mm average depth, with brick protection on the top of the each cable with 8 (eight) nos per mtr and 4(four) nos bricks per mtr as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed.
6
-
-
Laying of cable upto 3/3.5 core 35 sq mm - 50 sq mm on wall/surface incl. S&F MS saddle with earthing attachment in 2x10 SWG GI (hot dip) wire making holes etc. as necessary mending good damages and painting.
24
-
-
Supply & Fixing bulkhead light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceilling incl. 8 Watt CFL / 100watts GLS lamp complete set.
2
-
-
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]. Average run 6 mtr.
18
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By TATA-Medium GI pipe.
6
-
-
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
1.8
-
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of solid GI Wire size No. 4 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
24
-
-
Connecting the equpments/body to earth busbar including S&F 25 mmx6mm galvanised (Hot Dip) M.S flat on wall/ floor with GI shaddles as required and making connection to equipments with bolts,nuts and washers etc.
12
-
-
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
2
-
-
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting.
2
-
-
S & F at site of TW single board size 14" x 16".
2
-
-
Supply of fabricated MS Kiosk made from 14 SWG MS Angle incl. Providing Al busbar of 60 A rating for main supply transmission with proper stamping and to be fixed on pedestal as per direction of EIC.
2
-
-
Supply, delivery at site and storage of glowing plastic sign board for identification mark as per direction of EIC.
15
-
-
Erection of glowing plastic sign board for identification mark as per direction of EIC.
15
-
-
Supply & fixing, fitting of lightning arrestor/conductor of G.I stick of size 1x5 Mtr long x 25 mm dia with G.I flange at bottom of size 75 x 75 x 5 mm thk.with copper discharge points including grouting by cement morter 1:4 as per direction of EIC.
2
-
-
Operation & minor maintenance of pump house on trial run basis for 180 days per PH. (1semi skilled labour per station=180X2=360man days)
360
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements