Kolkata Metropolitan Development Authority Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Kolkata Metropolitan Development Authority - KMDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Sep 2024
Closing Date25 Sep 2024
Tender Amount₹ 12,59,457 
Notes
Download

Costs

Summary

Ing And Renovation Of A Part Of Existing Toilet Blocks Situated At Different Locations With Provision Of Ramps To Facilitate Physically Challenged Persons With In Boimela Prangan Bidhannagar.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm

31.39

3743

119.27

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation.

6.28

486

77.54

... More
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water ramming complete including the cost of supply of sand, (payment to be made on measurement of finished quantity)

17.19

22636

1317.14

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

62.19

22450

361

... More
25 mm. thick damp proof with cement concrete (1:1.5:3) .............[Bitument to be supplied by the Agency]

8.91

2322

260.64

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concretes slabs, beams, columns, lintels curved or straight i/c. fitting, fixing and striking out after completion of works. c) 9 to 12mm thick approved quality ply board shuttering in any concrete work. ground floor (f) 25 mm to 30 mm shuttering without staging in foundation

52.68

11010

209

... More
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In Ground Floor

89.93

33182

369

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes Rate Analysis Enclosed

4.66

24626

5284.7

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. ADD@95/-FOR UPPER FLOORS REF P-35/i-23

15.11

87108

5763.84

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.SAIL/ TATA / RINL

2.37

130464

54978.63

... More
Brick work with 1st class bricks in cement mortar (1:4) (a) In foundation and plinth

15.17

85135

5613.93

... More
(b) In superstructure, ground floor (Add extra for basement and each additional floor over the rate for ground floor on item of brickwork (a) Upto 4th floor)

22.28

130017

5836.93

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.(Add extra for each additional floor over the rate for ground floor on items from@12/- per sqm)

36

26226

728.5

... More
Labour for chipping of concrete surface before taking up plastering work.

89.93

1888

21

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 20 MM THICK cement mortar

94.77

17916

189.05

... More
PLASTER………….(Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 15 MM THICK cement mortar

89.45

14598

163.21

... More
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in roof.

18.38

4740

258

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a)(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground Floor

36.75

33810

920

... More
(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white In Ground Floor

62.37

65301

1047

... More
Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick

35.64

17107

480

... More
Anodised aluminium barrel /tower/ socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(ix) 300mm long x 12mm dia. bolt.

3

453

151

... More
Aluminium Louvered windows(B) In 15 Micron coloured Annodizing

2.7

21365

7913.33

... More
Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria 66mm x 70mm

14.85

6623

446

... More
Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor.(ii) 25 mm thick

4.73

12195

2581

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

6.68

218

32.75

... More
(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick)

89.45

9838

110

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat ii) Solvent based interior grade Acrylic Primer

89.45

3014

33.7

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer): (Two coats)(ii) Luxury Quality

89.45

6261

70

... More
Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of the EIC. Two coat

94.77

4274

45.1

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b)Normal Acrylic Emulsion

94.77

6349

67

... More
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointedwith white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi/ Udaypur pink / Udaypur Green / Black Bhaslana(i) Area of each Slab/tile upto 0.3 sq.m.

17.28

25160

1456.07

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor Grill weighing above 16 Kg./sq.mtr and above

9.99

96901

9696

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. at all floor.

62.46

1811

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. pin the surface, if necessary in all floors.(b) On steel or other metal surface With super gloss (hi-gloss) - [iv) Two coats (with any shade except white)

62.46

4934

79

... More
Supplying and application of chemical for post installed rebar connection by using ETA approved for seismic criteria in rebar connection , including drilling hole to the required depth by rotary hammer drill, cleaning with brush & jet of clean air , filling chemical using serrated nzzle to eliminate mixing error and in a voidless manner including charges for all tools & plants . application to be designed for post installed rebars aas per EC2/TR023 or relevant tested and accepted design guidelines and the design document to be furnished by the manufacturer. The chemical should have ETA approval for seismic criteria of rebar fixing of rebar fixing which should be furnished by manufacturer. The installation and the setting instruction s should be strictly followed as per manufacturer specification as approved by EIC prior to drilling along with post installed rebar embedment design report . The existing concrete member should be scanned using rebar scanner to avoid hitting existing reinforcement in concrete during drilling. Notes : 1)This rate Is excluding the cost of scaffolding. 2)Thls work should not be excuted without specific permission of Superentending Engineer of the respective circle and injection process should be executed in the presence of officer not below the rank Assistant Engineer to supervise the work minutely. 3) Rebar grouting Is specifically required for extension and strengthening purpose of old or existing RCCstructural members with new RCCstructural members through rebar fixing chemical Item without breaking beam, coloumn, roof slab, lintel, cellina etc.

-

-

-

... More
ii) Cost of post installed rebaring application with chemical as specified for 8mm dia per cm of depth

400

6400

16

... More
Cost of post installed rebaring application with chemical as specified for 10mm dia per cm of depth

160

2880

18

... More
Cost of post installed rebaring application with chemical as specified for 12 mm dia per cm of depth

240

5040

21

... More
Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with Concrete grade as specified as per Table 1 of IS 15658: 2006) manufactured from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No 3.26 of IS: 15658)and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CLNo.3.3 of IS: 15658) as per Table 2 of IS :15658 with flexural strength/breaking load as per Annexure G of IS:15658,on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP- 63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction,levelling and filling up of the edge gap. 60mm thick i) Colour and decorative.

4.86

5603

1153

... More
PLUMBING WORKS,

-

-

-

... More
Supplying, fitting and fixing UPVC down pipes A type and fittings conforming to IS 13592-1992 with necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete.

-

-

-

... More
i) UPVC Pipe 110 mm dia

22

5522

251

... More
ii) UPVC Bend 87.5 degree 110 mm dia

6

840

140

... More
iii) UPVC Shoe 110 mm

6

666

111

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (i) CPVC Pipes Class-1, SDR-11 a) For Exposed Work

-

-

-

... More
20 MM DIA

18

2574

143

... More
32 MM DIA

15

4245

283

... More
40 MM DIA

12.6

5077

403

... More
(b) For Concealed Work 15 mm Dia

12.4

1736

140

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.).

-

-

-

... More
20 MM DIA

1

657

657

... More
32 MM DIA

1

1258

1258

... More
40 MM DIA

1

1646

1646

... More
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with WallHook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).

3

3753

1251

... More
Supplying, fitting and fixing bib cock or stop cock.

-

-

-

... More
(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm

9

1386

154

... More
D(i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).

3

2445

815

... More
Suppling,fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with 'P' trap

3

4263

1421

... More
Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws supplied, fitted and fixed complete. (a) E.W.C. (ii) Plastic (hallow type) white

3

1140

380

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe

3

465

155

... More
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv) 600 mm long

6

642

107

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size

3

6624

2208

... More
Supplying, fitting and fixing pillar cock of approved make. b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). P.W.D. / S & P /P-45/It. No-19

3

666

222

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I, specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm

3

1839

613

... More
Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass (iii)25 mm dia. and 600 mm long

3

1290

430

... More
Supplying, fitting and fixing soap holder. (b) Fibre glass

3

174

58

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – Multilayer (g) 1000 litre capacity

1

5128

5128

... More
Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.

1

96

96

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.

2

38

19

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit,providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved makesupplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL)

1

7253

7253

... More
Cutting hole through wall,roof or cornice and mending good all damages. P.W.D. /S&P/P-97/It.-9

4

272

68

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm

18

3528

196

... More
(b) 110 mm

20

5840

292

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings (i) Coupler

-

-

-

... More
(a) 75 mm

2

92

46

... More
(b) 110 mm

2

170

85

... More
(ii) Plain Tee

-

-

-

... More
(a) 75 mm

2

92

46

... More
(b) 110 mm

2

170

85

... More
(iii) Door Tee (b) 110 mm

2

390

195

... More
vi) Door Y (LH) & (RH) (b) 110 mm

4

1104

276

... More
x) Bend 87.5º

-

-

-

... More
(a) 75 mm

2

122

61

... More
(b) 110 mm

2

240

120

... More
xi) Door Bend (T.S.) 110 mm

2

294

147

... More
xiv) Cross Tee with Door

-

-

-

... More
(a) 75 mm

2

432

216

... More
(b) 110 mm

2

478

239

... More
xv) Vent Cowl 110 mm

2

66

33

... More
xvi) Pipe Clip

-

-

-

... More
(a) 75 mm

3

48

16

... More
(b) 110 mm

3

63

21

... More
xviii) W.C. Connector (450 mm long) W / lipring (a) 75 mm

2

554

277

... More
xxiii) 110/110 S Trap

3

1302

434

... More
xxvi) Reducer 110 X 75 mm

2

160

80

... More
xxvii) Reducing Tee (110 X 75 mm)

2

284

142

... More
xIix) Door Gasket ( b)110 mm

2

16

8

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor)... (A) Above ground

-

-

-

... More
(a) 75 mm

42

1890

45

... More
(b) 110 mm

12

684

57

... More
Supplying, fitting and fixing C.I. round grating. 150 mm dia

3

255

85

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

3

3045

1015

... More
Add GST@18% on total of sl no1 to 85

1056768.45

190218

0.18

... More
Add L.Cess @1% on total of sl no1 to 86

1246986.77

12469

0.01



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.