Kalyani University Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Kalyani University Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date18 Nov 2022
Closing Date30 Nov 2022
Tender Amount₹ 4,29,661
Costs
EMD
₹ 8,593Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_UOK_423681_1Bid Award Id
ViewTender No
WD/3T-1/890Tender Authority
Kalyani University ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Laying of cable upto 3/4 core 25 sq.mm on wall / surface including S & F MS / GI saddle heavy type double screw system with earthing attachment in 2 x 10 SWG GI (Hot Dip) wire , making holes etc as necessary inclding mending good damages and possible finish .(F-1 / 2.b)
25
-
-
Laying of cable as below on existing cable tray and binding with suitable size GI wire / PVC tie. Upto 50 sq.mm (F-3 / 6.i)
10
-
-
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland.as per GS 4 Core 25 Sq. mm [7(c)/F4 ]
4
-
-
Finishing of the 3.5 / 4 core XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket (DOWELS) make , tapes , anticorrosive paste & jointing materials as per GS. 3.5 / 4 Core 25 Sq. mm [ 8(b) /F5 xiii]
4
-
-
Supplying & fixing sheet steel 16 SWG cable end box on the top of the TPN SFU Enclosure with nuts bolts etc. Including powder coated painting . (D - 5 / 5) 63 / 125 / 160A SFU (D - 5 / 5)
2
-
-
Supplying & fixing 415V 63A TPN SFU Seimens make as per Cat no. 3KL 8151-3TA10 including 3 nos. HRC din type fuse 63A on wall with iron frame / suitable size fastner with double nut including mending good damages & finish. (NS)
1
-
-
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection fixed in wall on iron frame / concealed in wall after cutting wall & mending good damages to original finish including inter connection with suitable size of copper wire and neutral link & provision for earthing attachment . as per GS ( Make - Siemens ) Siemens make 4 Way ( Enclosure 8GB32202RC04 ) [ D- 10 / 14 ]
1
-
-
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [ Make - Siemens] Siemens make 100 A FP [ D- 5 / 6 ]
1
-
-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make - Siemens ] Siemens make 6-32 A SP as per instruction of EIC [ D-6 / 7 ]
12
-
-
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make Medium / MMS ] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as per GS. (Should be use Precision make shaddle & the saddles should be fixed at 325mm interval ) 20mm size [ 7(a)/ E- 16 ]
75
-
-
25mm size [ 7(b)/ E- 16 ]
25
-
-
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall / stair by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 00mm x 100 mm x 65mm [11(a)/E-4]
160
-
-
150 mm x 100 mm x 65 mm [11(b)/E-4]
1
-
-
175 mm x 100 mm x 65 mm [11(c)/E-4]
1
-
-
200 mm x 150 mm x 65 mm [ 11 (d) / E -4 ]
2
-
-
240 mm X 200 mm x 65 mm [ 11(e) / E -4 ]
2
-
-
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 100mm x 100 mm x 65mm [13(a)/E-4]
160
-
-
150 mm x 100 mm x 65 mm [13(b)/E-4]
1
-
-
175 mm x 100 mm x 65 mm [13(c)/E-4]
1
-
-
200 mm x 150 mm x 65 mm [ 13 (d) / E -4 ]
2
-
-
240 mm X 200 mm x 65 mm [ 13 (e) / E -4 ]
2
-
-
Supplying & drawing 3 Core 2.5 Sq.mm multi core PVC insulated , PVC sheathed industrial cable with flexiable bright annealed copper conductor for voltage grade upto 1100V Gloster / FINOLEX (Gold) make in the existing suspended Ladder / pre laid rigid conduit precission make in the under ground trench etc as required including making connection complete . (Used for Flood lighting Installation ) (NS)
290
-
-
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised Hot Dip MS flat on wall / floor with GI Saddles / floor cutting / existing `L` hook as required and connecting to the equipments including drilled holes with bolts , nuts , washers etc. complete including mending good damages to finish as per GS [ G 3 / 5 d ] (For use of Earthing Connection & extended arm of 200W LED set.)
25
-
-
Cutting Channel of size (40 mm x 40 mm) / (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19/25 mm, 3 mm thick Polythene pipe (to be supplied as per sample provided) by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS. (For circuit drawing & as per requirement of Job / as per instruction of EIC) 19mm dia 3 mm thick polythene pipe as per sample. (Stair Cutting) [ 6(a)/ E- 2 ]
130
-
-
Supplying and Drawing 1.1 KV single core multistrand FRLSH / FR PVC insulated & unsheathed single core stranded copper wire Gloster / Finolex make in the following sizes prelaid polythene pipe as per GS. 2 x 22 / 0.3 (1.5 sqmm) [ E-9 / 1 a ]
10
-
-
3 x 22 / 0.3 (1.5 sqmm) [ E-9 / 1 b ]
75
-
-
2 x 36 / 0.3 (2.5 sqmm)+1 x 22 / 0.3 (1.5 sqmm) as ECC [ E-9 / 1 S ] [ 1(s) / E-9 ] ( For foot light connection)
180
-
-
2 x 56 / 0.3 (4 sqmm) ( Continuious running earthing from Busbars to TPN DBs ) [ E-9 / 1 (g)]
30
-
-
Supplying & fixing 200W LED Street Light luminaries Crompton make Cat Ref. - LFLN -200- CDL / 60-M Projected from the existing Ladder at 20 ft height for light installation system with GI flat clamping arrangement as per requirement made with 25x6 GI flat with nut bolts including suitable bend , drilled holes comlete including S&F GI clamp , nut bolts etc as required .[NS ]
12
-
-
Supplying & fixing 1100V grade heavy type 3 way best quqlity PVC connector as per instruction of EIC (approved by the EIC) (NS)
140
-
-
Supplying & Fixing Philips & Legrand Myrius make step light / foot light (The foot/step Lights should be fixing at stair) with necessary material & making connection complet after releasing the existing foot cover & should be re-setting the foot cove after completion of job & details of the foot / step lights are given below - At wall sides (Legrand make Myrius light) after cutting the existing wall protected ply wood / wooden cover cautiously & fixed 3 Module metal board with the help of 6.25 mm dia 150 mm (approx) / required size long fastner with double nuts system rigidly including S&F Legrand (Myrius) make foot light Cat no 6730 36 with 3 Module white LED 3W including flush mounting boxes (6890 08) , Cover plate + frame (6732 13) also making connection complete .
46
-
-
At opposite end i.e chair side fixing the Philips make 2 W white LED Step / foot light Cat no / Artical no.-30974 with the help of 32x6 mm GI Flat including suitable length & twisting bend / as per instruction of EIC and both end of the 32x6 mm GI flat should be drilled hole complete as per required dia whose one end shuold be fixed in the chair bolts & other end should be fixed at the middle of the existing inspection box 100x100x65mm with 6.25 mm dia & 25 mm long GI bolt , nuts & washers / as required and the foot / step light should be fitted / flushed in the inspection box after cutting the balelite top cover (as per size of LED light ) with addition should be driled at least 2 nos in the bakelight cover & flange of light & fixing the LED module with the help of 3/16 x 25mm long hex nut bolts & washer with the bakelite cover including making connection complete.
90
-
-
Dismantling the existing foot / step light cautiously without any damage of existing foot lights after releasing the stair fixing screws , necessary existing connections , foot cover etc as required / as per availablity at site / existing lights / exhaust fans etc. and the release materials should be deposited in KU store including carrying charges complete also including mending good damages & smooth finish (NS)
1
-
-
Supply & delivery of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC Electrical PVLtd) (NS) 230V 50 Hz 230MM / (9``) 1370 RPM
4
-
-
Fixing the supplied exhaust fan 9`` in the existing hole with the help of fixing nut bolts (6.25 mm dia & 100 mm long) around the existing hole with anti rotating facility after grouting the wall and mending good damages & finish. (NS)
4
-
-
Add Labour Cess 1%
1
-
-
Evaluation Notes How It Works ?
Potential Partner