Jadavpur University Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Jadavpur University - JU Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date29 Dec 2022
Closing Date13 Jan 2023
Tender AmountRefer Documents
Costs
EMD
₹ 2,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_JU_439388_1Bid Award Id
ViewTender No
JU/e-tender/EW/05/2nd Call/2022-23Tender Authority
Jadavpur University ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Air-cooled Outdoor Condensing Unit suitable for 415V ± 10%, 50Hz ± 5%, 3Ø AC Power Suply, complete with Hermetically Sealed Type Scroll Compressor for R410A Refrigerant, Drive Motor, Air-cooled Condenser with protective coating and Propeller Type Fan with motor and other standard accessories, housed in compact powder coated sheet metal enclosure
Nominal Capacity - 11TR
8
-
-
Microprocessor Controller suitable to control four numbers Condensing Units having Fault Display, Run-time equaliser, Touch key switch, time delay for compressor, temperature control etc
2
-
-
Insulation of refrigerant piping can be of elastomeric Class-O nitrile rubber tubing of specified thickness covered with glass cloth at site for Mechanical protection.
-
-
-
Suction Line 1.1/8 " / 28.57MM OD with 19MM thick Tubing Insulation
80
-
-
Liquid Line - 1/2" / 12.7 MM OD with 13MM thick Insulation
80
-
-
14SWG Perforated GSS Cable Tray for Laying of Refrigrant Piping
80
-
-
Condensing Unit accessories for 11TR Units like Drier, Hand Shutoff Valvs, Thermostatic Expansion Valves etc. required to make the circuit complete
8
-
-
Ductable Split Air conditioner Units with Air-cooled Outdoor Condensing Unit suitable for 415V ± 10%, 50Hz ± 5%, 3Ø AC Power Suply, complete with Hermetically Sealed Type Scroll Compressor for R410 Refrigerant, Drive Motor, Air-cooled Condenser with protective coating and Propeller Type Fan with motor and other standard accessories, housed in compact powder coated sheet metal enclosure and Ceiling Suspended Indoor Unit in Powder Coated Construction complete with Non wovn Polyester media Air Filter enclosed in HDPE mesh, DX Type Cooling Coil, Condensat Drain Pan, DIDW Centrifugal Fan with Forward Curved Impeller and Drive Motor complete all necessary accessories like Microporocessr based Controller with LED Display, Contactor for Compressor, Capacitor for Outdoor Fan, Single Phase Preventor, Safety Pressure Switch, Crank Case Heater, Thermostatic Expansion Valve, Drier, Shut off Valve etc
Nominal Capacity - 8.5TR , Air Flow - 3400CFM
1
-
-
Inter-connecting Refrigerant Piping between Outdoor Unit and Indoor Unit with 20SWG thick hard drawn Copper Seamless Pipes and Fittings and insulated with Factory laminated Glass Cloth coated Elastomeric Nitrile Insulation 19MM / 13MM Thick
-
-
-
Suction Line 7/8 " / 22.2MM OD with 19MM thick Tubing Insulation
20
-
-
Liquid Line - 3/8" / 9.5 MM OD with 13MM thick Insulation
20
-
-
14SWG Perforated GSS Cable Tray for Laying of Refrigrant Piping
20
-
-
Double Skin Supply Air Plenum in 25MM Sandwich Insulated Construction with Extruded Aluminium Frame Structure and 25MM Polyurethane Foam density 40 ± 2 Kg/Cumtr injected between outer skin of 0.6MM Pre-coated GSS and Inner Skin of 0.6MM Plain GSS, Plenum Dimension will be 1850W X 650H X 450MM D. Plenum will be provided with 3Nos Jet Nozzles, suitable to handle total of 3400CFM flushed with it.
2
-
-
Double Skin Return Air Plenum in 25MM Sandwich Insulated Construction with Extruded Aluminium Frame Structure and 25MM Polyurethane Foam density 40 ± 2 Kg/Cumtr injected between outer skin of 0.6MM Pre-coated GSS and Inner Skin of 0.6MM Plain GSS, Plenum Dimension will be 1850W X 650H X 350MM D. Plenum will be provided with a Return Air Grill of suitable size. Suitable Access Door shall be provided for attending to Inddor Unit Filter.
2
-
-
Ceiling Susension arrangement for Indoor Unit and Plenums with necessary GI Suspendors and Slotted Channels etc.
2
-
-
Acoustic Insulation of AHU Room Wall between Auditorium and AHU Room with fiber free Open Cell Nitrile Rubber foam Density 140-180 Kg/Cumtr - 15MM Thick, stuck to the wall with manufacturer recommended adhesive. All longitudinal and transverse joints shal be sealed with 50MM Wide - 22SWG GI Strips fixed with Screws
75
-
-
Acoustic Insulation of Supply Air Duct from inside with fiber free Open Cell Nitrile Rubber foam Density 140-180 Kg/Cumtr - 15MM Thick, stuck to the wall with manufacturer recommended adhesive
600
-
-
Thermal Insulation of Suply Air Ducting with 19MM thick Closed Cell Elastomeric Nitrile Rubber Insulation with factory backed Aluminium Foil one one Side fixed to Ducting by manufacturer recommended adhesive. Maximum Thermal Conductivity of the Insulation Material shall be 0.035 Wa/ (m-K)
700
-
-
GI volume control Damper within ducts to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system as per direction of EIC complete with locking arrangement
-
-
-
Motorized Fire damper of 90 mins Fire Rating as per specification with Limit Switch, Actuator, Some & Fire Sensor Controller
3
-
-
Fire Damper
3
-
-
Spring Return Type Actuator suitable for 230V AC Power Supply for above
2
-
-
Limit Switch for above
2
-
-
Control Panel for above
2
-
-
GSS sheet metal rectangular ducting as per specification complete with accessories as specified
-
-
-
24 G GI Sheets
450
-
-
22 G GI Sheets
150
-
-
20 G GI Sheets
10
-
-
GI Fresh Air Intake louvers with Bird/Insect Screen and GI Volume Control Damper Size 750MM X 600MM
2
-
-
Extruded Aluminium powder coated Fixed Bar Supply Air Grille with removable core and Integral Extruded Aluminium Black Volume Control Dampers
6
-
-
Extruded Aluminium powder coated Fixed Bar Return Air Grille without Volume Control Dampers
9
-
-
Condensate drain water piping with CPVC pipes, rated for 6Kg/cm2 as insulated with 6mm thick Elastomeric Nitrile insulation from respective Air Handling Units to nearest floor drain point
40 mm dia
30
-
-
MS Structural base for placement of Outdoor condensing units duly painted with two coats of Zinc rich primer followed by two coats of Synthetic enamel paint
500
-
-
Floor / Wall mounted TOP Connection cubicle type indoor compartmentalized 415V., 50 Hz. dust & moisture proof LT Distribution panel board with following electrical accessories fabricated from 14 SWG CRCA sheet with MS angle frame as requried. . The panel should have adequate strength & space to accommodate the incoming & outgoing switches and bus-bars with all interconnection in between the switches and bus-bars with copper flat / flexible wire of suitable capacity. The panel should be provided with cable alley for facilitating connection of all the incoming & outgoing FRLS Cables with termination arrangement by S&F copper terminal stud / bolt of required sizes. The panel board should consist with the followings:-
(A) INCOMER:-
a) 415V., 250 Amp. 36 KA 4-Pole MCCB with Thermal - Magnetic release , - 1 No.
(B) BUSBAR CHAMBER:-
200 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu bars - 1set.
(C) OUTGOING:-
a) 415V., 40Amp. 36 KA 4-Pole MCCB with Thermal - Magnetic release, - 4 Nos. for Condensing Units
b) 415V., suitable rating of MCCB, suitable rating FASD starter for operation of AHU Motor with over load relay, inbuilt single phasing protection, ON & OFF switch and outgoing feeder to Air Handling Unit Motor. The compartment shall contain an indicating lamp for ‘ON’ & OFF status - 4 nos
c) 16Amps - 230V - MCB Feeder - 1 No (Spare)
(D) METERING:-
(a) 500V., C.T. Coil (C.T. Ratio-200/5A.) - 1 Nos.
(b) LED Indicator lamps - 03 nos.
(c) Panel mounted digital Voltmeter in 96x96 mm² (AE/ HPL) [0 - 500 Volt] - 01 no.
(d) Panel mounted digital Ammeter in 96x96 mm² [0 - 200 Amp.] - 01 no.
(e) Danger Board - 01 no.
2
-
-
Power and Control Cabling between Panel and drives with PVC Armoured, PVC Sheathed 1100V FRLS Cables with Copper Conductor as per IS 1225 complete with end terminations with Doube Compression Cable Glands laid on 14SWG Perforated GSS Cable trays
-
-
-
4C X 10 Sqmm - Copper Conductor
120
-
-
3C X 6 Sqmm - Copper Conductor
30
-
-
7C x 1.5 Sqmm - Copper Conductor
210
-
-
4C x 1.5 Sqmm - Copper Conductor
60
-
-
2C x 1.5 Sqmm - Copper Conductor
60
-
-
Earthing between Equipment and Panel with 4Sqmm X 1C Copper Cable (unarmoured - GREEN)
200
-
-
First Charge of Refrigerant - R410A for the complete installation
Commissioning, Balancing and Performance Testing of the complete Installation
1
-
-
PART - B
ALL INCLUSIVE ANNUAL MAINTENANCE CONTRACT CHARGES FOR 3 YEARS AFTER DEFECTS LIABILITY PERIOD
-
-
-
1st YEAR AFTER DLP
1
-
-
2ND YEAR AFTER DLP
1
-
-
3RD YEAR AFTER DLP
1
-
-
PART - C
BUY BACK FOR THE EXISTING AIR CONDITIONING SYSTEM
-
-
-
Dismantling, Removal and disposal of the existing Air Conditioning System
1
-
-