Irrigation And Waterways Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Irrigation And Waterways Department Tender

Works
Civil And Construction
Irrigation Work
Eprocure
Opening Date15 Feb 2024
Closing Date23 Feb 2024
Tender Amount₹ 9,57,059 
Notes
Download

Costs

Summary

E-n.i.t No - Wbiw/ee/bdd/e-nit-16e /2023-24, Sl-02

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
IN 1ST FLOOR.

0.52

3627

6975.6

... More
IN 2 nd FLOOR.

0.4

2836

7088.82

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation, basement and upto roof. (i) Tor steel/Mild Steel (b) JSW/ JSPL/SRMB/ BMASL/ ELECROSTEEL/SSL IN GROUND FLOOR.

0.22

14669

65782.4

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. IN GROUND FLOOR.

8.06

3218

399.25

... More
IN 1ST FLOOR.

8.06

3391

420.71

... More
IN 2 nd FLOOR.

4.9

2167

442.16

... More
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.

715.95

16209

22.64

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints ncluding throating, nosing and drip course, scaffolding/staging where necessary. (i)With 1:4 cement mortar (b)20 mm thick plaster IN GROUND FLOOR.

312.45

70361

225.19

... More
IN 1ST FLOOR.

282.45

64952

229.96

... More
IN 2 nd FLOOR.

106.07

24897

234.72

... More
(ii)With 1:4 cement mortar (c)10 mm thick plaster IN GROUND FLOOR.

45.61

7092

155.49

... More
IN 1ST FLOOR.

45.61

7309

160.26

... More
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. IN GROUND FLOOR.

48.99

2919

59.59

... More
IN 1ST FLOOR.

48.99

3270

66.74

... More
Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.

53.01

2067

39

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles etc. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative IN GROUND FLOOR.

48.99

53132

1084.54

... More
IN 1ST FLOOR.

48.99

53424

1090.5

... More
Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative IN GROUND FLOOR.

36.54

48295

1321.71

... More
IN 1ST FLOOR.

36.54

48513

1327.67

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coat ii) Solvent based interior grade Acrylic Primer IN GROUND FLOOR.

313.43

18117

5780.23

... More
IN 1ST FLOOR.

311.57

18273

5864.85

... More
IN 2 nd FLOOR.

22.83

1358

5949.47

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer): (Two coats) Standard Quality

647.83

47868

73.89

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

152.6

6911

45.29

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

35.55

1229

34.56

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface: With other than hi-gloss - (iv)Two coats (with any shade except white)

152.6

13641

89.39

... More
(b) On steel or other metal surface: With other than hi-gloss - (iv)Two coats (with any shade except white)

35.55

3051

85.81

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. One Coat. IN GROUND FLOOR.

105.74

3957

3742.25

... More
IN 1ST FLOOR.

105.74

4047

3826.87

... More
IN 2 nd FLOOR.

88.01

3443

3911.49

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat) b) Premium 100% Acrylic Emulsion IN GROUND FLOOR.

105.74

10586

100.11

... More
IN 1ST FLOOR.

105.74

10676

100.96

... More
IN 2 nd FLOOR.

88.01

8960

101.81

... More
Renewing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. In cement concrete(1:2:4) including cutting of brick work/concrete work as per direction. (a) 40 mm X 6 mm, 250 mm Length

100

5601

56.01

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, as per relevant IS codes. Pakur Variety IN GROUND FLOOR.

3.22

20200

6273.37

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

15

429

28.6

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iv)75 mm. X 63 mm. X 3.20 mm.

32

2364

73.89

... More
(v)100 mm. X 63 mm. X 3.20 mm.

52

4462

85.81

... More
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (b) 250 mm long.

8

1516

189.5

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (vii) 225 mm long x 10 mm dia. bolt.

20

2002

100.11

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:With continuous plate base (Hexagonal/ Round rod) (v)125 mm grip x 12 mm dia rod.

12

1473

122.76

... More
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. Upto area 2.5 Sq.m

59.64

8458

141.82

... More
Shutters of 2/3rd panel and 1/3rd glazed of doors and windows as per design (each panel consisting of a single plank etc. (iii) 35mm thick shutters with 19mm thick panel. Sishu, Gamar, Champ,Badam, Bhola, Mogra, Hallak. IN GROUND FLOOR.

5.99

22794

3806.61

... More
IN 1ST FLOOR.

5.99

23001

3841.17

... More
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. 35 mm thick shutter. Sishu, Gamar, Champ,Badam, Bhola, Mogra, Hallak. IN GROUND FLOOR.

7.5

26351

3513.43

... More
IN 1ST FLOOR.

5.77

20472

3547.99

... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (f) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. IN GROUND FLOOR.

0.29

25847

90691.21

... More
IN 1ST FLOOR.

0.29

25915

90929.57

... More
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge.

6.1

17724

2905.61

... More
Supplying, Fitting & Fixing Factory made prelaminated P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm Prelami- nated PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as perManufacturer ‟specification and direction of Engineer-in-Charge."

28.38

13022

458.84

... More
Supplying best Indian sheet glass panes set in putty (as per I.S specification) and fitted and fixed with teak wood beads and nails complete. (In all floors for internal wall & upto 6 m height for external wall) 3 mm thick (weighing 7.4 kg/Sq.m)

2.16

2005

928.41

... More
Supplying, fitting and fixing shower of approved brand and make. PTMT overhead shower (Prayag or equivalent) 150 mm round

4

1621

405.21

... More
Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap (with vent)

4

14797

3699.35

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.

4

4839

1209.68

... More
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size

4

10526

2631.49

... More
Dismantling wash basin with brackets with or without waste fittings.

4

167

41.71

... More
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. Sink only 630 mm X 550 mm X 180 mm

4

18058

4514.54

... More
Dismantling sink with brackets with or without waste fittings. (i) Upto 450 mm length

4

191

47.67

... More
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 450 mm long

8

782

97.73

... More
Supplying,fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 900 mm long

8

715

89.39

... More
Indian W.C. including taking out base concrete as necessary.

4

215

53.63

... More
Supplying, fitting and fixing bib cock or stop cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).

8

5139

642.38

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm

4

2922

730.57

... More
Supplying, fitting and fixing PTMT Smart Shelf of approved make of size 300 mm.

4

1063

265.77

... More
Supplying, fitting and fixing towel rail with two rackets.C.P. over brass 25 mm dia. and 600 mm long

12

6150

512.47

... More
Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. b) Slab Thickness above 25 mm and upto 37.5 mm For Ground floor

3.61

3068

849.75

... More
IN 1ST FLOOR.

3.61

3119

864.06

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

1.5

17677

11784.52

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm.

2.63

374

14214.6

... More
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. ground floor

0.87

463

532.73

... More
IN 1ST FLOOR.

0.87

515

592.32

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof. (a) upto 150 mm. thick 3rd floor

1.01

1311

1297.87

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

15

6454

430.24

... More
Brick work with 1st class bricks in cement mortar (1:4) (a) Superstructure 3rd floor

0.38

2643

6953.97

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

7.5

6510

868

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (I) CPVC Pipes Class-1,SDR-11 15 mm dia

35

4422

126.33

... More
20 mm dia

15

2556

170.43

... More
(b) For Concealed Work (I) CPVC Pipes Class-1,SDR-11 15 mm dia

15

2503

166.85

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992A)     (i) Single Socketed 3 Meter Length (a) 75mm

28

6541

233.59

... More
(b) 110 mm

16

5568

348.01

... More
xvi) Pipe Clip (b) 110 mm

10

250

25.03

... More
(a) 75mm

14

267

19.07

... More
x) Bend 87.5º (a) 75mm

4

291

72.7

... More
(b) 110 mm

4

572

143.02

... More
xv) Vent Cowl (a) 75mm

4

119

29.8

... More
(b) 110 mm

4

157

39.33

... More
vii) Double Y 110mm

6

1959

326.55

... More
v) Plain Y 110mm

6

1473

245.51

... More
(ii) Plain Tee 75mm

4

219

54.82

4

405

101.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.