Irrigation And Water Resources Department Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Irrigation And Water Resources Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 40,87,272 
Notes
Download

Costs

Summary

Renovation Of Elec. Illumination System At Keyatala Sluice, Dhosa Sluice, Hobka Sluice, Suryapur Stackyard, Dhosa Rest Shed, Joynagar Irrigation Division, Mograhat Drainage Division Compound..majilpur, Mograhat, Baruipur, Dist.- South 24 Parganas.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.

540

67

36682.2

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.

37

545

20196.08

... More
Supply and fixing of smart bright street light (36 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Philips, 36 watt

22

6335

139383.42

... More
Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Philips, 68 watt

15

7410

111159.15

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 2 core, upto 10 sq mm

74

137

10142.44

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : For 2 core, 10 sq mm

74

40

2998.48

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages Solid GI Wire No. 6 SWG

560

15

8674.4

... More
SITC of Feeder Pillar panel box of dim : 2mm thk CRCA sheet of dimension : 750mm (H) x 500 mm (B) x 300 mm (D) double door, with double coated powder paint having the following materials including fixing the same in CC foundation of (1:3:6) as per enclosed drawing with base frame structure made by 25 x 25 x 5 mm thk MS angle, as per direction of EIC. 1. MCCB DU100H, 25-32A, Cat No : CM97898OOE2, Braking Cap : 65KA Make L & T = 1 NO 2. Supply of 22.5 mm dia LED indicating lamps = 1 No 3. Fr 1, 2P Power Contactor, 32A, MNX 22-2P, Cat No : CS90238, Make : L & T = 1 NO 4. FM1 / Quartz Daily, 240 VAC Base/DIN Mounting, Cat No : J648B1, Make : L & T = 1 No 5. Multi Step Switches with OFF, 2 P 3W, Cat No : 61080, 32A, Make : L & T = 1 No 6. Single Pole (SP) MCB 6A, C Curve, Cat No : BB10060C, make : L & T = 1 NO. 7. 32A, Double pole (DP) MCB C curve, Cat No : BB20320C, Make : L & T = 1 NO Including Power Circuit Connection by 10 sq mm stranded CU wire & Timer Control circuit connection by 2.5 sq mm

3

26173

78519.36

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

3

1631

4894.71

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil

3

256

768.72

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required

6

185

1115.52

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

3

1090

3271.5

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

3

632

1898.55

... More
PART B : Illumination of Suryapur Stackyard Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980 9m length, 133Kg, 410-SP-30

23

21267

489156.41

... More
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts

23

3378

77711.25

... More
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box

23

1238

28480.44

... More
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS.

-

-

-

... More
2 CORE, 6 sq mm (for gate light)

25

190

4767.25

... More
2 CORE, 25 sq mm (for st light)

596

296

176868.96

... More
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.

621

193

119896.47

... More
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp.

10

19

190.7

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. ISI Medium, 25 mm dia

14

206

2886.52

... More
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 200 x 150 x 100mm

27

593

16025.04

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :

-

-

-

... More
2 core 6 sqmm cable

8

38

305.12

... More
2 core 25 sqmm cable

48

81

3889.92

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :

-

-

-

... More
For 2 core upto 6 sq mm

8

81

648.32

... More
For 2 core upto 25 sq mm

48

157

7551.36

... More
Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Crompton, 72 watt

23

9559

219866.89

... More
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole

-

-

-

... More
One coat of red lead/Zinc chromate priming

23

233

5372.57

... More
1st coat of synthetic enamel paint over the primer

23

178

4111.71

... More
2nd coat of synthetic enamel paint over the 1st coat

23

163

3755.44

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

1

1631

1631.57

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil

1

256

256.24

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

1

1090

1090.5

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

1

632

632.85

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand, SP, 6-32 A

27

226

6113.88

... More
Supply and fixing of Havells Post top Luminaries model no : CORAL PT35WLED (35Watt) over the preinstalled GI Pipe over the gate structure or similar structure incl. connection by 1.5 sq mm cu wire from loop box to the light.

4

11597

46389.64

... More
SITC of Feeder Pillar panel box of dim : 2mm thk CRCA sheet of dimension : 750mm (H) x 500 mm (B) x 300 mm (D) double door, with double coated powder paint having the following materials including fixing the same in CC foundation of (1:3:6) as per enclosed drawing with base frame structure made by 25 x 25 x 5 mm thk MS angle, as per direction of EIC. 1. MCCB DU100H, 25-32A, Cat No : CM97898OOE2, Braking Cap : 65KA Make L & T = 1 NO 2. Supply of 22.5 mm dia LED indicating lamps = 1 No 3. Fr 1, 2P Power Contactor, 32A, MNX 22-2P, Cat No : CS90238, Make : L & T = 1 NO 4. FM1 / Quartz Daily, 240 VAC Base/DIN Mounting, Cat No : J648B1, Make : L & T = 1 No 5. Multi Step Switches with OFF, 2 P 3W, Cat No : 61080, 32A, Make : L & T = 1 No 6. Single Pole (SP) MCB 6A, C Curve, Cat No : BB10060C, make : L & T = 1 NO. 7. 32A, Double pole (DP) MCB C curve, Cat No : BB20320C, Make : L & T = 1 NO Including Power Circuit Connection by 10 sq mm stranded CU wire & Timer Control circuit connection by 2.5 sq mm

1

26173

26173.12

... More
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

5

109

548.25

... More
SITC of GI Earthing spike of size 1833 MM x 20 mm including inserting at required depth and connection by supplying and fixing GI (Hot dip) strip 20mm x 3 mm thick from earth spike to pole (2.5 Mtr distance from earth spike connection point to pole) complete in all respect as per direction of the EIC.

23

824

18968.79

... More
PART C : Outdoor illumination and SITC of AC Machines at Dhosa Rest shed Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980 9m length, 133Kg, 410-SP-30

8

21267

170141.36

... More
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts

8

3378

27030

... More
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box

8

1238

9906.24

... More
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS.

-

-

-

... More
2 CORE, 10 sq mm (for st. light)

150

232

34860

... More
2 CORE, 6 sq mm (for Bollard & Post top)

87

190

16590.03

... More
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.

237

193

45757.59

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 8 SWG

10

10

107.3

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. ISI Medium, 25 mm dia

32

206

6597.76

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint (for st light + bollard)

29

545

15829.36

... More
Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm thick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary (for Bollard Lighting)

17

297

5065.15

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :

-

-

-

... More
2 core 10 sqmm cable

18

40

729.36

... More
2 core 6 sqmm cable

34

38

1296.76

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :

-

-

-

... More
For 2 core upto 10 sq mm

18

137

2467.08

... More
For 2 core 6 sqmm cable

34

81

2755.36

... More
Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Philips, 68 watt

13

7410

96337.93

... More
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole

-

-

-

... More
One coat of red lead/Zinc chromate priming

8

233

1868.72

... More
1st coat of synthetic enamel paint over the primer

8

178

1430.16

... More
2nd coat of synthetic enamel paint over the 1st coat

8

163

1306.24

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

1

1631

1631.57

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil

1

256

256.24

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

1

1090

1090.5

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

1

632

632.85

... More
Supply and fixing of LED Bollard (10watt) complete with all accessories, Make : Havells, 10 watt

17

9529

162003.71

... More
SITC of 1 No Glow Sigange Board for DHOSA REST SHED as per enclosed drawing Supply and installation of Polyvinylidene Fluoride coated Aluminium Composite Panel board (3mm) of Aludecor /Alstone size (as per drawing)to be made such a manner that it can be opened towards up direction for taking maintenance. (0.5M x 0.5M X 1 board) = 0.25 sqm = 2.69 sqft

3

221

665.01

... More
S&F of Acrylic letter scripted in English/Bengali. size and matter of letter as per approved drawing by EIC, front side of the letter to be made 6mm thick imported (White- 0.40) uv stabilized excellent to self display. Make Acast, Mitsubishi, all letter will be raised minimum 2" to be fixed by special type of solution. (total sqm of Each letter is to be measused based on its front surface area) (As per enclosed Drawing) 0.16 sqm

0.16

13691

2190.62

... More
S & F LED lamp incl. best quality LED lighting arrangement to be fixed by proper arrangement with complete connection. (1 module contain 3 nos LED, 0.5 W Each) board letter surface area 0.16 sqm (248 sq inch) considering 90% area will be covered by LED lights, 3sq inch (surface area of each module) = (248x 90%)/3 sq inch = 100 nos

100

63

6317

... More
S&F Water proof power supply system IP65, output volatge : 12V/24V DC, 50/60Hz frequency, 108 to 305 VAC power supply, .95 power factor for LED lamp. (Make : Meanwell) 200 Watt, Model ELG 200

1

5975

5975.69

... More
26 Gauge Galvanized iron sheet for back panel with one coating of white paint, Make - Aarti / Bansal / Jindal

3

151

454.08

... More
M.S. structural works with hollow sections ( square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. a) Span up to 12 Mtr 25 x 25 hollow bar, thk = 4 mm,

0.01

70115

490.81

... More
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment, 2 way

2

321

643.58

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand, DP, 6-32 A

2

650

1301.44

... More
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)

15

121

1823.4

... More
SITC of GI Earthing spike of size 1833 MM x 20 mm including inserting at required depth and connection by supplying and fixing GI (Hot dip) strip 20mm x 3 mm thick from earth spike to pole (2.5 Mtr distance from earth spike connection point to pole) complete in all respect as per direction of the EIC.

8

824

6597.84

... More
Supply and fixing of Havells Post top Luminaries model no : CORAL PT35WLED (35Watt) over the preinstalled GI Pipe over the gate structure or similar structure incl. connection by 1.5 sq mm cu wire from loop box to the light.

4

11597

46389.64

... More
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 200 x 150 x 100mm (For Post Top)

4

593

2374.08

... More
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm)

48

157

7551.36

... More
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

4

934

3737.48

... More
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.

4

420

1682.84

... More
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.

4

153

614.96

... More
Supply and Installationof Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC. 1.5 Ton (Make : Hitachi) 3 star non-inverter type

4

52005

208021.52

... More
SITC of Feeder Pillar panel box of dim : 2mm thk CRCA sheet of dimension : 750mm (H) x 500 mm (B) x 300 mm (D) double door, with double coated powder paint having the following materials including fixing the same in CC foundation of (1:3:6) as per enclosed drawing with base frame structure made by 25 x 25 x 5 mm thk MS angle, as per direction of EIC. 1. MCCB DU100H, 25-32A, Cat No : CM97898OOE2, Braking Cap : 65KA Make L & T = 1 NO 2. Supply of 22.5 mm dia LED indicating lamps = 1 No 3. Fr 1, 2P Power Contactor, 32A, MNX 22-2P, Cat No : CS90238, Make : L & T = 1 NO 4. FM1 / Quartz Daily, 240 VAC Base/DIN Mounting, Cat No : J648B1, Make : L & T = 1 No 5. Multi Step Switches with OFF, 2 P 3W, Cat No : 61080, 32A, Make : L & T = 1 No 6. Single Pole (SP) MCB 6A, C Curve, Cat No : BB10060C, make : L & T = 1 NO. 7. 32A, Double pole (DP) MCB C curve, Cat No : BB20320C, Make : L & T = 1 NO Including Power Circuit Connection by 10 sq mm stranded CU wire & Timer Control circuit connection by 2.5 sq mm

1

26173

26173.12

... More
PART D : Outdoor illumination at Campus area of Mograhat Drainage Division & Joynagar Irrigation Division Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km

4

773

3093.92

... More
Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980) 9m length, 133Kg, 410-SP-30

10

21267

212676.7

... More
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts

10

3378

33787.5

... More
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box

10

1238

12382.8

... More
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS.

-

-

-

... More
2 CORE, 6 sq mm (for Bollard Lighting + wall fixing light)

82

190

15636.58

... More
4 CORE, 16 sq mm (for St Lights)

340

352

119941.8

... More
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.

392

193

75683.44

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. No. 8 SWG

30

10

321.9

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. ISI Medium, 25 mm dia

35

206

7216.3

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.

27

545

14737.68

... More
Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm thick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary (for Bollard Lighting)

17

297

5065.15

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :

-

-

-

... More
2 core 6 sqmm cable

37

38

1411.18

... More
4 core 16 sqmm cable

20

113

2264.4

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :

-

-

-

... More
For 2 core upto 6 sq mm

37

81

2998.48

... More
For 4 core 16 sqmm cable

20

157

3146.4

... More
Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Philips, 68 watt

18

7410

133390.98

... More
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint, Upto 9.0 mtr. long pole

-

-

-

... More
One coat of red lead/Zinc chromate priming

10

233

2335.9

... More
1st coat of synthetic enamel paint over the primer

10

178

1787.7

... More
2nd coat of synthetic enamel paint over the 1st coat

10

163

1632.8

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe (for St Light Feeder Pillar)

1

1631

1631.57

... More
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil

1

256

256.24

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

1

1090

1090.5

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

1

632

632.85

... More
Supply and fixing of LED Bollard (10watt) complete with all accessories, Make : Havells, 10 watt

17

9529

162003.71

... More
SITC of 2 Nos Glow Sigange Board for Joynagar Irrigation Division & Mograhat Drainage Division & 1 NO Board for Sub-Division Office Supply and installation of Polyvinylidene Fluoride coated Aluminium Composite Panel board (3mm) of Aludecor /Alstone size (as per drawing)to be made such a manner that it can be opened towards up direction for taking maintenance. (3.0M x 1.5M x 2 Boards + 6.0M x 1.5M x 1 board) = 18 sqm = 193.75 sqft

194

221

43003.98

... More
S&F of Acrylic letter scripted in English/Bengali. size and matter of letter as per approved drawing by EIC, front side of the letter to be made 6mm thick imported (White- 0.40) uv stabilized excellent to self display. MakeAcast, Mitsubishi, all letter will be raised minimum 2" to be fixed by special type of solution. ( total sqm of Each letter is to be measused based on its front surface area) (As per enclosed Drawing) 1.26sqm + 1.15sqm + 2.72 sqm = 5.13 sqm

5.13

13691

70236.88

... More
S & F LED lamp incl. best quality LED lighting arrangement to be fixed by proper arrangement with complete connection. (1 module contain 3 nos LED, 0.5 W Each) board letter surface area 5.13 sqm (7952 sq inch) considering 80% area will be covered by LED lights, 3sq inch (surface area of each module) = (7952x 80%)/3 sq inch = 2200 nos

2200

63

138974

... More
S&F Water proof power supply system IP65, output volatge : 12V/24V DC, 50/60Hz frequency, 108 to 305 VAC power supply, .95 power factor for LED lamp. (Make : Meanwell) 200 Watt, Model ELG 200

12

5975

71708.28

... More
26 Gauge Galvanized iron sheet for back panel with one coating of white paint, Make - Aarti / Bansal / Jindal

194

151

29363.84

... More
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment, 2 Way

3

321

965.37

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand, DP, 6-32 A

3

650

1952.16

... More
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)

50

121

6078

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface] Average run 5 mtr

16

785

12566.4

... More
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]. On Board

2

257

514.86

... More
Supply and fixing of EnduraLED Bulkhead Pressure Die cast housing LED bulkhead with IP66 Protection and IK09 impact resistance suitable for surface and wall mounting applications on ceiling fitting on wall /ceiling by screws etc. Make: Crompton, 10 watt LED

16

1356

21700.32

... More
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp

392

19

7475.44

... More
SITC of GI Earthing spike of size 1833 MM x 20 mm including inserting at required depth and connection by supplying and fixing GI (Hot dip) strip 20mm x 3 mm thick from earth spike to pole (2.5 Mtr distance from earth spike connection point to pole) complete in all respect as per direction of the EIC.

10

824

8247.3

... More
SITC of Feeder Pillar panel box of dim : 2mm thk CRCA sheet of dimension : 825mm (H) x 500 mm (B) x 300 mm (D) double door with double coated powder paint having the following materials including fixing the same in CC foundation of (1:3:6) as per enclosed drawing with base frame structure made by 25 x 25 x 5 mm thk MS angle, as per direction of EIC. Material Description : 1. MCCB DU100H, 50-63A, Cat No : CM97933OOH2, Braking Cap : 30KA Make L & T with extended ROM rotary handle= 1 no 2. 22.5 mm dia LED indicating lamps = 1 no 3. Fr 2, 4P Power Contactor, 63A, MCX 12, Cat No : CS97014, Make : L & T = 1 No 4. FM1 / Quartz Daily, 240 VAC Base/DIN Mounting, Cat No : J648B1, Make : L & T = 1 NO 5. Multi Step Switches with OFF, 2 P 3W, Cat No : 61080, 32A, Make : L & T = 1 NO 6. Single Pole (SP) MCB 6A, C Curve, Cat No : BB10060C, make : L & T = 1 NO 7. 32A, Double pole (DP) MCB C curve, Cat No : BB20320C, Make : L & T = 1 NO BUS BAR : 25 X 5 mm thk CU Busbar 400 MM (L) x 4 Nos All internal power connection to be made by 10 sq mm CU wire, control circuit wiring by 2.5 sq mm CU wire.

1

35147

35147.37

... More
For new AC machine Line connection Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand, 2+8 WAY, Enclosure (607711)

1

1760

1760.29

... More
Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 25 mm dia 3 mm thick polythene pipe without earth continuity wire

5

132

661.45

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC

5

295

1477.85

... More
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

6

934

5606.22

... More
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works, 2 Module.

6

204

1229.94

... More
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

6

232

1394.4

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
Legrand 6-32A, SP

8

226

1811.52

... More
Legrand 63A, DP

1

1117

1117.91

... More
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm)

75

157

11799

... More
Back side frame structure for Glow Sign Boards M.S. structural works with hollow sections ( square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. a) Span up to 12 Mtr 25 x 25 hollow bar, thk = 4 mm,

0.12

70115

8694.38



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.