Indian Army Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Indian Army Tender
Machinery and Tools
GEM
Opening Date15 Oct 2024
Closing Date6 Nov 2024
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
CATEGORY: Open Jaw Wrenches (Spanners) as per IS 2028 (Q3) , Dismantling of Old Us Distribution Boards alongwith its all accessories i.e. MCCB MCB wiring etc ,
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5463675Tender No
GEM/2024/B/5463675Tender Authority
Indian Army ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
235___17_2024-10-02-20-51-12_fe8809e3725b3dfd28f960b253be7809.pdf
235___17_2024-10-02-20-51-12_f54675cb85a0bad179ca1a9965b3fb01.csv
BOQ Items
AS PER SERIAL NO. 3 BUT SIZE 16 Sqmm 4 Core , (b) 16 Sqmm 4 Core
650
-
-
AS PER SERIAL NO. 3 BUT SIZE 25 Sqmm 4 Core , (c) 25 Sqmm 4 Core
400
-
-
AS PER SERIAL NO. 3 BUT SIZE 35 Sqmm 3.5 Core , (d) 35 Sqmm 3.5 Core
250
-
-
AS PER SERIAL NO. 3 BUT SIZE. 50 Sqmm 3.5 Core , (e) 50 Sqmm 3.5 Core
150
-
-
Relaying of existing cable XLPE Insulated galvanized steel strip or wire armoured electric power cables 1100 Volts 10 Sqmm 4 Core 2Core , Relaying of existing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes. (a) 10 Sqmm 4 Core/2 Core Note . Earth work shall be measured and paid seperately.
450
-
-
AS PER SERIAL NO. 3 BUT SIZE 16 Sqmm 4 Core. , (b) 16 Sqmm 4 Core.
450
-
-
AS PER SERIAL NO. 3 BUT SIZE 25 Sqmm 4 Core. , (c) 25 Sqmm 4 Core.
350
-
-
AS PER SERIAL NO. 3 BUT SIZE 35 Sqmm 3.5 Core. , (d) 35 Sqmm 3.5 Core.
350
-
-
AS PER SERIAL NO. 3 BUT SIZE 50 Sqmm 3.5 Core , (e) 50 Sqmm 3.5 Core
150
-
-
M and L for Excavation in trenches upto 1.5m deep Hard dense soil , M & L for Excavation in trenches upto 1.5m deep (Hard/dense soil)
617
-
-
M and L for Sand filling in trenches including watering and consolidation , M & L for Sand filling in trenches including watering and consolidation
182
-
-
M and L for removing of surplus excavated soil , M & L for removing of surplus excavated soil
226
-
-
M and L for Returning and filling of surplus excavated soil , M & L for Returning and filling of surplus excavated soil
391
-
-
Supply and laying Burnt clay fly ash building bricks designation 75Kg cm2 complete all as specified. , Supply and laying Burnt clay fly ash building bricks designation 75 Kg cm2 complete all as specified.
33
-
-
M and L for Floor of tiles PCC Footpath cutting through existing PCC floor Footpath approx size width 15cm or as required X 60cm as required , M&L for Floor of tiles /PCC/Footpath cutting through existing PCC/floor/Footpath approx size width 15cm or as required X 60cm (as required) depth as required for Realying/Laying of cable/ pipe etc and making good with and including earthwork and necessary excavation, complete material required to match with the existing one or with PCC 1.2.4 type B1 complete all as specified and as directed by EIC.
190
-
-
SPN Distribution Board 8 way 230V 50Hz IP54 and IK09 Suitable for Surface mounting with 100 A copper Busbar for each phase , SPN Distribution Board , 8 way, 230V,50Hz, IP54 & IK09, Suitable for Surface mounting, with 100 A copper Busbar for each phase, With fully shrouded Neutral Bar, Earth bar and Cable ties for cable management, as per IEC 61439 3 Make Legrand Cat Part No 507641 with Reversible Door, MCB SPN 40 A to 63 Amp Incomer 01 Nos, MCB SP 6 to 32 Amp Outgoing 04 Nos
90
-
-
S and F Distribution Box 4 way 430V 50Hz IP54 and IK09 Suitable for Flush mounting and Surface mounting with 100 A copper Busbar for each phase , Supply & fix Distribution Box , 4 way, 430V,50Hz, IP54 & IK09, Suitable for Flush mounting and Surface mounting, with 100 A copper Busbar for each phase, With 2 Neutral Bar, 2 Earth bar and Cable ties, as per IEC 61439 3 , Make Legrand Cat Part No 507735 ,Cable management , Fully insulated busbar & shrouded Neutral bars , Improved Pan assembly for ease of installation, Prefitted masking sheet , Reversible Door DBs , With provision for FP MCB as incomer and SP/TP MCBs as outgoing. Incomer MCCBs 100 A 415V, 16 KA, 4 Pole Complete all as specified Outgoing Shall be paid and measured seperately
33
-
-
S and F Distribution Box 4 Module 230V 50Hz IP65 and IK09 classII weatherproof cabinets Door and Cabinet fully reversible Removable chassis and faceplates , S & F Distribution Box , 4 Module, 230V,50Hz, IP65 & IK 09 class II, weatherproof cabinets, Door and Cabinet fully reversible, Removable chassis and faceplates, including weatherproof galnds, rails, etc Cat Part No 6019 94 Make Legrand Incomer 32 AMP MCB SPN 01 Nos Outgoing 6 to 32 Amp SP 02 Nos
34
-
-
S and F Automatic changeover with current limiter ACCL SPN 30A 30A Automatic source chage over between Mains and Generator supply Break , S & F Automatic changeover with current limiter(ACCL) SPN 30A/30A ,Automatic source chage over between Mains & Generator supply Break before make change over system Buzzer and Led Indication of status, Current limitation prevents overloading of the generator including SMC/FRP Box for Fixing ACCL of size (Inside Dimension) 270 X 225 X 135
19
-
-
S and F MCB SP 240V 10 KA B curve miniature circuit breaker MCB of single poles and current carrying capacity 6 to 32 AMP , Supply and fixing MCB SP 240V, 10 KA B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB Complete with connection testing and commissioning.
198
-
-
M and L for Wiring for circuit submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor single core cable , M & L for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed in PVC Conduit as required of size 06 Sqmm 2x6.0 sq. mm + 1x6.0 sq. mm earth wire complete all as specified and directed.
979
-
-
Earthing for poles and other machinery equipment using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm , Earthing for poles & other machinery/equipment using 4 mm GI wire as earthing lead and MS galvanized plate of size 60 cm x 60 cm x 6 mm, as earth electrode including dismantling existing one
66
-
-
S and F Cable Junction Box, made of CRCA Sheet Single door outdoor type factory made and assembled of size not less than 450x150x450 , Supply & Fix Cable Junction Box, made of CRCA Sheet Single door outdoor type factory made and assembled of size not less than 450x150x450(LXBXH) with 3.15mm thick CRCA Sheet, with aluminium Busbar 03 Nos for RYB Phase and 01 No as Neutral Busbar for 200 Amp , angle iron supports up to each 0.6 Mt height duly painted with anti corrosive black paint and grouted in PCC 1.3.6 at suitable depth/floor mounting with fasteners, nut bolts etc as per site requirement incuding dismantling existing one.
41
-
-
M and L for plain concrete cement 1.3.6 type C2 using 40mm graded coarse aggregate for foundation of Busbar Box including necessary form work , M&L for plain concrete cement 1.3.6 type C2 using 40mm graded coarse aggregate for foundation of Busbar Box including necessary form work including PCC demolition of busbar Box of any type any description and in any postion
10
-
-
M and L for Plywood of 09 mm thick grade BWR type BB fixed with screws to puff panel work complete for fixing of DBs , M & L for Plywood of 09 mm thick, grade BWR, type BB, fixed with screws to puff panel work complete for fixing of DBs complete all as specified and directed.
18
-
-
M and L for Straight through LT cable heat shrinkable jointing kit suitable for LT UG of following sizes cable complete a. 10 Sqmm 4 Core. , M&L for Straight through LT cable heat shrinkable jointing kit suitable for LT UG of following sizes cable complete Make. 3M /Mseal (a) 10 Sqmm 4 Core.
10
-
-
AS PER SERIAL NO. 3 BUT SIZE 16 Sqmm 4 Core , (b) 16 Sqmm 4 Core
10
-
-
AS PER SERIAL NO. 3 BUT SIZE 25 Sqmm 4 Core , (c) 25 Sqmm 4 Core
6
-
-
AS PER SERIAL NO. 3 BUT SIZE 35 Sqmm 3.5 Core , (d) 35 Sqmm 3.5 Core
6
-
-
AS PER SERIAL NO. 3 BUT SIZE 50 Sqmm 3.5 Core , (e) 50 Sqmm 3.5 Core
6
-
-
M and L for fixing of MCCBs in replacement of 100 Amps 3 Pole 415 Volts thermal nd magnetic adjustable type 0.8 to 1In Magnetic Adjustable 5 to 10In , M & L for fixing of MCCBs in replacement of 100 Amps, 3 Pole , 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole , Ics 100% Icu, with spreader links and Phase barriers including taking down existing one complete all as specified and directed
9
-
-
M and L for fixing of MCCBs in replacement of 125 Amps 3 Pole 415 Volts thermal nd magnetic adjustable type 0.8 to 1In Magnetic Adjustable 5 to 10In , M & L for fixing of MCCBs in replacement of 125 Amps, 3 Pole , 415 Volts thermal & magnetic adjustable type 0.8 to 1In, Magnetic Adjustable 5 to 10In, Breaking capacity 16 kA, 4 Pole , Ics 100% Icu, with spreader links and Phase barriers complete all as specified and directed.
6
-
-
S and Fix HDPE Pipe of 50mm dia for protection of cable under the floor etc complete all as specified and directed , S & Fix HDPE Pipe of 50mm dia for protection of cable under the floor etc complete all as specified and directed
180
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements