Health And Family Welfare Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Health And Family Welfare Department - HFWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Apr 2023
Closing Date10 May 2023
Tender Amount₹ 29,45,979 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)

41.9

3248

77.54

... More
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)

8.36

5011

599.61

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.

107.58

2581

24

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).

3.53

683

194

... More
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.

180.09

58710

326

... More
Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering.

6.1

30872

5061.53

... More
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. 100 km

3.14

15788

5025.45

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes

38.83

214633

5527.32

... More
First floor

17.72

99636

5622.32

... More
Staircase Head Room

3.38

19331

5717.32

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(Jsw/jspl/shyam/srmb/bmasl/electrosteel), A) In foundation upto + Ground Floor Roof

3.66

201913

55199.27

... More
B) In Ground floor Slab To First Floor Roof Slab

1.67

92867

55629.27

... More
C)In First Floor Roof Slab To Staircase headroom

0.32

17854

56059.27

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete work Foundation & Ground floor

284.54

103856

365

... More
First floor

171.65

65740

383

... More
Staircase Head Room Total

40.28

16151

401

... More
Brick work with 1st class Bricks with cement morter (1:6), i) In Foundation & Plinth, a) above tie beam wall

12

58593

4882.81

... More
Ground floor, ii) In Superstructure

16.28

83116

5105.81

... More
First floor

16.67

86977

5216.81

... More
Second floor

5.56

29629

5327.81

... More
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) , Ground floor

89.81

60133

669.56

... More
First floor , ii) In Superstructure

64.93

44250

681.56

... More
Second floor

29.77

20290

681.56

... More
Labour for Chipping of concrete surface before taking up Plastering work. ground floor

58.93

1237

21

... More
First floor

57.38

1204

21

... More
Second floor

12.44

261

21

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary. Outside plaster(20 mm. thk), Ground floor

137.65

21980

159.68

... More
First floor

117.86

19290

163.68

... More
Second floor

111.16

18639

167.68

... More
Inside plaster(15 mm. thk) , Ground floor

309.38

43223

139.71

... More
First floor

287.44

41308

143.71

... More
Second floor

15.52

2292

147.71

... More
Ceiling plaster(10 mm. thk), Ground floor

58.93

7349

124.71

... More
First floor

57.38

7385

128.71

... More
Second floor

12.44

1650

132.71

... More
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

19.65

643

32.75

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement , Roof area

58.91

15080

256.01

... More
Extra cost of labour over grey artificial stone for (i) Chequering

58.91

883

15

... More
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.

19.64

2336

119

... More
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. Ground floor

52.05

65763

1263.43

... More
First floor

53.59

67969

1268.43

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 ......................... (White cement, synthetic adhesive and grout material to be supplied by the contractor). Ground floor

19.6

17757

906

... More
Kota stone vertical, First floor

11.66

10559

906

... More
Ground floor

7.86

7121

906

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. , b) Area of each tile above 0.09 Sq.m, Ground floor

7.02

4921

701

... More
First floor

3.51

2478

706

... More
With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. , (a) Area of each tile upto 0.09 Sq.m, Wall , Ground floor

32.76

23063

704

... More
First floor

16.38

11613

709

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Ground floor

368.31

25781

70

... More
First floor

344.82

24137

70

... More
Second floor

27.96

1957

70

... More
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Ground floor

137.65

6208

45.1

... More
First floor

117.86

5398

45.81

... More
Second floor

111.16

5171

46.52

... More
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Ground floor

137.65

11562

84

... More
First floor

117.86

9983

84.71

... More
Second floor

111.16

9495

85.42

... More
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete.

14.85

4143

279

... More
PVC 26 Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid hinges, hasp bolt, tower bolt,door ring etc. In ground floor.

3.15

7204

2287

... More
first floor

1.58

3624

2301

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.

4.73

20459

4330

... More
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.

0.47

47

100.9

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs . (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

1.82

17982

9888

... More
First floor

2.21

22021

9986.88

... More
Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. Ground floor

18.59

538

29

... More
First floor

16.56

480

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with Other than Hi Gloss

35.15

2776

79

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge.

93.06

41690

448

... More
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white

213.57

82224

385

... More
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work). i)Top, bottom and side member

7.2

1317

183

... More
ii) Louvered Section

3.24

2131

658

... More
iii) Cleat angle ( Non-annodized)

3.24

852

263

... More
g) Fixed glazing i)Top, bottom and side member.

9

2889

321

... More
ii) Mulion

9

3051

339

... More
iii) Glazing clip.

1.62

81

50

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (vii) 100x75x4.00 mm

66

6138

93

... More
Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.

11

2332

212

... More
Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units, (iv) fixed glazing

1.62

1244

768

... More
(v) Louvered window

1.08

788

730

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. i) 4 mm thick clear glass.

12.42

4941

398

... More
viii) 8mm thick coloured / tinted / smoke glass.

6.28

5697

907

... More
Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge. In ground floor

6.31

5552

880

... More
In first floor

3.96

3538

894

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:

22

2090

95

... More
Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (vii) 225mm long x 10mm dia. Bolt

11

924

84

... More
(iv)150mm long x 10mm dia. Bolt

11

693

63

... More
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting

11

1749

159

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: , (ii) 110 mm. Dia.

20.7

5195

251

... More
a) Plain Tee , (ii) 110 mm. Dia.

3

516

172

... More
b) Plain Y, (ii) 110 mm. Dia

3

669

223

... More
c) Bend 87.5 degree, (ii) 110 mm. Dia.

3

420

140

... More
d) Shoe , (ii) 110 mm. Dia.

3

333

111

... More
Sanitary & Plumbing Works ( As per EIC )

1

164789

164789

... More
Electrical Works ( As per EIC )

1

210650

210650

... More
G.S.T@18%

1

444937

444937.19

... More
Labour Welfare Charge@1%

1

29168

29168.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.