Haldia Development Authority Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Haldia Development Authority - HDA Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date19 Nov 2024
Closing Date3 Dec 2024
Tender Amount₹ 26,38,359 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation of 10 Mtr long G.I octagonal pole.

50

780

39000

... More
Preparation of RCC foundation of 550 dia for Mini Mast and 500 mm dia for street Light and 1800 mm height (1500 mm below the Ground Level and 300 mm above the Ground Level) with required rod, cement, chips and sand etc. at the ratio 1:1:5:3 with ground bolt 4 nos. for fixing the 10Mtr Height G.I Octagonal pole & 12 Mtr Height Mini mast (excluding supply and delivery of Nut Bolts).

51

7370

375870

... More
Erection, Testing and commissioning of 12 Mtr High Mast on existing civil foundation by bolts with Suitable Tool, Tackles, Machines etc. All complete as per direction of EIC

1

25483

25483

... More
Installation of Feeder Pillar Box only on Cement Brick foundation including plastering and neat cementing as per specification and direction of EIC.

4

2396

9584

... More
Supply, drawing and Connection of luminaries with 3C X 1.5 Sqmm [Make : Havells/Finolex] pvc insulated FR copper conductor through 10 mtr. Poles from looping box to light fittings as required.

51

494

25194

... More
Fixing only Street / Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. (excluding the cost of RCC Foundation)

53

559

29627

... More
Supply and fixing of SPMCB "C" Curve 1-4 Amp [Make: Legrand/L&T] with ISI marked to be placed on a din channel of Pole and supply and fixing of Terminal connector at the suitable location of the pole.

51

196

9996

... More
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/tubular Pole, on brick foundation of meter box, feeder pillar box. (3 nos. Logo p/pole, per meter box, per feeder pillar box.)

162

100

16200

... More
Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire with the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole).

51

200

10200

... More
Supply and delivery of 1.1 KV grade 4 C X 25 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1 with latest amendment if any. The cable should have ISI mark.(Make: Havells, Gloster, Polycab)

2596

310

804760

... More
Supply and delivery of 1.1 KV grade 4 C X 16 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1 with latest amendment if any. The cable should have ISI mark.(Make: Havells, Gloster, Polycab)

100

253

25300

... More
Supply of HDPE Plb Duct pipe of size 32/26 mm.

2150

38

81700

... More
Laying of Cable by Jack push method through micro tunneling 2-3M deep under black top surface with excavation of double earth pit 1400×600×3000 mm on hard soil, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe)

72

945

68040

... More
Supply GI earth Spike (1830 X 20 mm) (Each Pole).

51

358

18258

... More
Earthing complete with driving of earth spike & connection of Earth electrode with noncurrent carring metallic parts of supports (Each Pole).

51

267

13617

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. ( 2.8 sqmm per panel x 4+1.54sqmm Pole/Mini mast x 51)

89.74

42

3819.33

... More
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. ( 2.8 sqmm per panel x 4+1.54sqmm Pole/Mini mast x 51).

89.74

110

9950.37

... More
Laying of one No. cable upto 35 Sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.

230

167

38410

... More
Laying of one No. HDPE Pipe in underground trench 460 mm wide x 760 mm average depth including filling the trench with shifted soil, leveling up and restoring surface duly rammed.

2150

101

217150

... More
Laying only Cable upto 50 sq.mm through existing RCC/Hume/ GI /HDPE Pipe/open masonry trench for single, 2, 3, 3½ & 4 core

2150

44

94600

... More
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia

72

340

24480

... More
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. 4 Core X 16 Sqmm

160

98

15680

... More
4 Core X 25 Sqmm

240

118

28320

... More
Connecting the equipments body to earth bus bar including S & F 50 mm x 6 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc

18

204

3672

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

6

1410

8460

... More
Excavation of soil for installation of Earth Electrode and filling & ramming (a) For Soft Soil

6

221

1326

... More
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe.

6

942

5652

... More
18% GST

2213760

-

398476.8

... More
1% CESS

2612237

-

26122



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.