Haldia Development Authority Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Haldia Development Authority - HDA Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date8 Jun 2024
Closing Date22 Jun 2024
Tender Amount₹ 22,83,739
Costs
EMD
₹ 45,700Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HDA_689757_1Bid Award Id
ViewTender No
02/HDA/EC-ELECT/2024 2025Tender Authority
Haldia Development Authority ViewPurchaser Address
-Website
http://https://www.hda.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply & delivery of LED Flood light of following specification: a) 200 W (+/-5%) for each set.
b) System efficiency at Luminaries level shall be minimum 120 Lumen/Watt whereas LED Chip level efficiency shall be minimum 160 Lumens/ Watt. c) The luminaries should be of IP 66 protection, Driver IP 66 & IEC 61000-4-5
d) In put Voltage of 130 V – 270 Volt, 50 Hz. A.C. supply
e) Driver should have in-built protection against high voltage surge, open circuit & short circuit.
f) Housing should be of Die-cast aluminium housing with epoxy powder coating and having cooling fins for effective heat dissipation. Separate cavity for driver & LED lamp.
g) Operating Temperature: 0 deg to +55 Degree C with a relative humidity of 10-95% RH
h) Third party test report from NABL accredited laboratory of LM-79, LM-80 & IP-66. i) CRI (Color Rendering Index) shall be 70 or above.
j) Make of LED Chip:- Nichia, Cree, Osram, Lumileds. k) Life of LED shall be rated at 50,000 Hrs or above.
l) Correlated Color Temperature normal (CCT) 3700K m) The luminaries withstand voltage stress of 440V for 8 Hrs, should have an auto shutdown @325V and have an auto recovery feature. n) The product should have 5 years warranty period.
4
-
-
Supply, delivery & transportation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal/polygonal Mini-mast (single section) with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 6 nos. of non integral flood light fittings (with luminaries mounting plate and provision of passing wire) along with G I nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. The rate should include testing at your works, all taxes and delivery the materials at different locations of HDA planning area. (Make: UTKARSH INDIA LTD/TRANSRAIL LIGHTING LIMITED/BAJAJ ELECTRICALS LTD).
1
-
-
Erection, Testing and commissioning of the Mini Mast 12 Mtr. With modern engineering practice (Excluding the cost of RCC foundation).
1
-
-
Supply and fixing of Pole numbering Sticker (5" X 3") at the street light pole.
51
-
-
Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire with the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole).
51
-
-
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/tubular Pole, on brick foundation of meter box, feeder pillar box.
105
-
-
Laying of GI pipe by Jack push method through micro tunneling 2-3M deep under black top surface with excavation of double earth pit 1400×600×3000 mm on hard soil, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe).
7
-
-
Supply and fixing of 1-4 A SPMCB "C" Curve, 10 KA (Legrand/ L&T/Havells).
54
-
-
Earthing with Supply & erection of GI earth Spike (1830 X 20 mm) (Each Pole).
50
-
-
Supply of 1.1 KV grade 4 C X 10 Sqmm XLPE insulated and PVC sheathed aluminium armoured Cable, As per IS 7098.Make-KEI/Glaster/Havells/Policab/RR.
1950
-
-
Supply, delivery, installation, testing & commissioning of single phase Feeder pillar box of size 1000 X 750 X 525 mm made of 3 mm x 6mm MS plate including suitable foundation with foundation bolt coated outdoor type with top canopy, sides having lovers for ventilation, double door thick CRCA steel sheet with zinc powder coated outdoor type with top canopy, sides having lovers for ventilation, double door, complete with components iron clad bus bar chamber on iron frame with 4 bars,415V,63A,4x20x5 mm and 1 no 4P 32 A MCB ,4 no 4P 16A MCB.1 no. timer switch model TSQ-100 type QTN,1 no contactor cat no- SS90910(or equivalent,1 no auto manual selector, Push Bottom sets and 2 nos. earthing with 50mm dia. GI pipe. Installation of the feeder to be done by the earth cutting, brick soiling and cc foundation as required & sand filling, ramming and muffing around the feeder pillar box by brick and cement mortar work as per the direction of the Engineer-in-charge.
3
-
-
Fixing only Flood light fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
4
-
-
Fixing Street light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
50
-
-
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting, b) 250 x 250 x 100mm.
51
-
-
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required. 3 x 22/0.3 (1.5 sqmm)
500
-
-
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required. 3 x 22/0.3 (2.5 sqmm)
30
-
-
RCC Foundation for 12 Mtr. high mast as per the enclosed drawing and details schedule.
1
-
-
Erection of single steel tubular pole of length upto 9 mtrs. With sole plate in C.C. (6:3:1) foundation 0.6x0.6x1.91 mtrs. as to G.S. having 600x600x150 mm thick C.C. (4:2:1) base block below sole plate with jhama metal incl. C.C. (6:3:1) muffing 0.3 mtr. dia & 0.3 mtr. above ground level including 3 mm thick neat cemented finish & providing GI earth bolt after making drilled holes etc. on the pole & carriage of pole upto 1.6 km from store depot. to work site including filling up the excavated earth pit with shifted soil & ramming properly. Size 0.6x0.6x1.70 mts.
50
-
-
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (ii) No. 6 SWG
100
-
-
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (0.35 sqm per pole x 50 + 2.8 sqm per panel x 3+1.54sqm mini mast x 1).
27.72
-
-
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint. (0.35 sqm per pole x 50 + 2.8 sqm per panel x 3+1.54sqm mini mast x 1). (b)Two coats.
27.72
-
-
Laying of one No. cable upto 35 Sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed, for looping cable.
100
-
-
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 40 mm dia
10
-
-
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i) 4 core X 10 sqmm
110
-
-
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. i) 4 core X 10 sqmm.
110
-
-
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
20
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe.
4
-
-
Excavation of soil for installation of Earth Electrode and filling & ramming. (1Cu mtr. X7).
4
-
-
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
4
-
-
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. DP 10Amps
1
-
-
Providing and fixing typical citizen information board constructed with BFS, PCC, 250 mm & 125 mm brick wall (1:4) with necessary 15 mm thick plastering (1:4) & rule pointing, including supply & fixing of white marble stone (1100mm X 800mm X 18mm) with black colour engraved lettering as per the enclosed drawing.
3
-
-
Supply of HDPE pipe conforming to IS-4984-1985 (Dia) [PE-63], 6Kg/Sq.cm(Working Pressure), 40mm Dia.
1640
-
-
Laying of PVC/GI/MS pipe in UG trench 460mm width x 760mm avg. depth including excavation, filling the trench with shifted soil, leveling up and restoring the surface duly rammed for 40mm dia.
1647
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements