Haldia Development Authority Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Haldia Development Authority - HDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date11 Aug 2023
Closing Date8 Sep 2023
Tender Amount₹ 2,17,89,221 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Ref:- PWD(B)-17, Page no-2, Item no-4(A)

85.6

46524

-

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Ref:- PWD(B)-17, Page no-14, Item no-1

434.59

150368

-

... More
Ordinary Cement concrete (mix 1:3:6) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes.(A) Pakur Variety Ref:- Derrived rate.

60.95

280883

-

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. (i) 35 mm thk. (i)Ground Floor. Ref:- PWD(B)-17, Page no-48, Item no-6(iii)

25

8025

-

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. Ref:- PWD(B)-17, Page no-47, Item no-3.

136

3264

-

... More
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. Ref:- PWD(B)-17, Page no-47, Item no-4.

10

2780

-

... More
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. Ref:- PWD(B)-17, Page no-45, Item no-9.

10

2570

-

... More
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. Ref:- PWD(B)-17, Page no-45, Item no-8b.

5

595

-

... More
Antitermite treatment to back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS-6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). Ref:- PWD(B)-15-16, Page no-5, Item no-10-D.

174.62

23922

-

... More
Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hardwood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (i)25 mm to 30 mm shuttering without staging in foundation Ref:- PWD(B)-2017, Page no-42, Item no-36(a)

338.64

109719

-

... More
(ii) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (upto roof of ground floor) Ref:- PWD(B)-2017, Page no-42, Item no-36(c)

490.25

175999

-

... More
(iii) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. 1st Floor. Ref:- PWD(B)-2017, Page no-42, Item no-36(c)+d(i)

260.16

98080

-

... More
iv) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. 2nd Floor. Ref:- PWD(B)-2017, Page no-42,It-36(c)+d(i)

260.16

102763

-

... More
vi) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. Above Roof. Ref:- PWD(B)-2017, Page no-42, Item no-36(c)+d(i)

772.48

332938

-

... More
Providing Bored Cast-in-situ M25 grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2). (b) Using tripod, winches.(i) Pile diameter - 500 mm. Ref:- PWD(B)-2017, Page no-36, Item no-24(b)(i)+ M25 grade Concrete rate.

1426

1894640

-

... More
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor. (b) above 150mm thick. Ref:- PWD(B)-2017, Page no-11, Item no-2(b)

108.61

153900

-

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Ref:- Derrived rate.

25

144753

-

... More
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade. (i) Pakur Variety. (i) foundation & ground floor Ref:- Based on Rate Analysis

160

988892

-

... More
(ii) 1st floor Ref:- Based on rate analysis + Page no-35, Item no-23(i)

50

313779

-

... More
(iii) 2nd. Floor Ref:- Based on rate analysis + Page no-35, Item no-23(i)

50

318529

-

... More
(iv) Above roof Ref:- Based on rate analysis + Page no-35, Item no-23(i)

28

181036

-

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.[SRMB, ELEGANT, CAPTAIN, RASHMI) (a) Tor steel. (i) For works in foundation and upto roof of ground floor/upto 4 m. Ref:- PWD(B)-2017, Page no-44, Item no-40(a)(i)(I) Derrived rate.

65.63

3751017

-

... More
ii) 1st. Floor to 2nd. Floor Ref:- PWD(B)-2017, Page no-44, Item no-40(a)(i)(I) + (b)(i) Derrived rate.

7.85

452034

-

... More
iii) 2nd. Floor to 3rd. Floor Ref:- PWD(B)-2017, Page no-44, Item no-40(a)(i)(I) + (b)(i) Derrived rate.

7.85

455409

-

... More
iv) Above Roof Ref:- PWD(B)-2017, Page no-44, Item no-40(a)(i)(I) + (b)(i) Derrived rate.

4.4

257153

-

... More
Brick work with 1st class bricks in cement mortar (1:4). In foundation and plinth. Ref:- Derrived rate.

16.5

89060

-

... More
Brick work with 1st class bricks in cement mortar (1:6). (i) In Super Structure, Ground Floor. Ref:- Derrived rate. Ref:- PWD(B)-2017, Page no-15, Item no-8 (b)

12.4

66645

-

... More
(ii) First Floor Ref:- Derrived rate. PWD(B)-2017, Page no-15, Item no-8

19.2

105324

-

... More
(iii) Second Floor Ref:- Derrived rate. PWD(B)-2017, Page no-15, Item no-8

19.2

107456

-

... More
(iv) Upper roof & Mumty Ref:- Derrived rate. PWD(B)-2017, Page no-15, Item no-8

18.55

105877

-

... More
125mm thick brick work with 1st class bricks in cement mortar (1:4). (i) In Super Structure, Ground Floor. Ref:- PWD(B)-2017, Page no-16, Item no-16

228.68

161095

-

... More
(ii) First Floor Ref:- Derrived rate, PWD(B)-2017, Page no-17, Item no-24(b)

220.35

157431

-

... More
(iii) Second Floor Ref:- Derrived rate, PWD(B)-2017, Page no-17, Item no-24.

197.53

143102

-

... More
(iv) Upper roof Ref:- Derrived rate, PWD(B)-2017, Page no-17, Item no-24.

33.26

24428

-

... More
Extra for using approved H.B. netting in every third layer in 125 mm. thick brick work in any floor Ref:- PWD(B)-2017, Page no-16, Item no-18

679.82

27872

-

... More
Plaster (to wall,floor,ceiling etc)with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating,nosing and drip course, scaffolding /staging where necessary(Ground floor)(excluding cost of chipping over concrete surface) Extra for each additional floor over the rate for Upto 4th floor. with 1:6 cement mortar. 20mm thick plaster ( External wall ) (i) Ground Floor Ref:- PWD(B)-2017, Page no-189, Item no-1(i)b Derrived rate.

74.4

12950

-

... More
(ii) First Floor Ref:- PWD(B)-2017, Pg-193,It-1(a) Derrived rate.

148

26352

-

... More
(iii) Second Floor Ref:- PWD(B)-2017, Pg-193,It-1, Derrived rate.

148

26944

-

... More
(iv) Upper roof Ref:- PWD(B)-2017, Pg-193,It-1, Derrived rate.

49.6

9228

-

... More
Plaster (to wall,floor,ceiling etc)with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating,nosing and drip course, scaffolding /staging where necessary(Ground floor)(excluding cost of chipping over concrete surface) Extra for each additional floor over the rate for Upto 4th floor. (i) Ground Floor. 15mm thick plaster (Internal wall ) with 1:6 mortar. Ref:- PWD(B)-2017, Page no-189, Item no-1(i)(C) Derrived rate.

500.98

68393

-

... More
(ii) First Floor Ref:- PWD(B)-2017, Pg-193,It-1 Derrived rate.

473.74

66569

-

... More
(iii) Second Floor Ref:- PWD(B)-2017, Pg-193,It-1 Derrived rate.

433.58

62660

-

... More
(iv) Upper roof Ref:- PWD(B)-2017, Pg-193,It-1 Derrived rate.

99.34

14753

-

... More
Plaster (to wall,floor,ceiling etc)with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating,nosing and drip course, scaffolding /staging where necessary(Ground floor)(excluding cost of chipping over concrete surface) Extra for each additional floor over the rate for Upto 4th floor. with 1:4 cement mortar. 10mm thick plaster (Ceiling). (i) Ground Floor Ref:- PWD(B)-2017, Page no-189, Item no-1(iii)(c). Derrived rate.

161.98

19845

-

... More
(ii) First Floor Ref:- PWD(B)-2017, Page no-189, Item no-1. Derrived rate.

139.26

17619

-

... More
(iii) Second Floor Ref:- PWD(B)-2017, Page no-189, Item no-1. Derrived rate.

177.01

23103

-

... More
(iv) Third Floor Ref:- PWD(B)-2017, Page no-189, Item no-1. Derrived rate.

10.98

1477

-

... More
Labour for Chipping of concrete surface before taking up Plastering work. Ref:- PWD(B)-2017, Page no-192, Item no-1

451.48

9481

-

... More
Water proofing treatment over roof as per following: i) Cleaning the concrete surface by removing dirt and debris,marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge Ref:- PWD(B)-2017, Page no-45, Item no-5

200

18000

-

... More
ii) Applying 2 coats of bonding agent with synthetic multi functional rubberemulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification Ref:- PWD(B)-2017, Page no-45, Item no-8(a)

200

17600

-

... More
iii) Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in aney floor as per relevant IS codes. Ref:- Derrived rate.

25.45

147359

-

... More
iv) Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point 150 deg C, Cold Flexibility -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse). (PWD SOR-2018, Page No-92 Item No-4) Ref:- PWD(B)-2017, Page no-92, Item no-4.

216

87912

-

... More
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)(size not Iess than 600mmX 600 mm X 9.5 mm thick) (i) ln Ground FIoor: Ref:- PWD(B)-2017, Page no-69, Item no-41(a)

25

39150

-

... More
(ii) First floor

90

142020

-

... More
(iii) Second floor

90

143100

-

... More
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance 0.5, Mohr's hardness 5.0, Staining resistance: Class-1, Water Absorption: E 0.5%], MOR 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete includingthe cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength 1500 N. (i) Ground floor. Ref:- PWD(B)-2017, Page no-280, Item no-1(b)

12

18960

-

... More
(ii) First floor

200

318400

-

... More
(iii) Second floor

200

320800

-

... More
Supplying, fitting & fixing true to line and level digital elevation Ceramic tiles of approved brand conforming to IS:15622:2006 Group B III and tested as per IS:13630:2006 as ornamental cladding on external wall in natural stone, brick, wood, bamboo pattern/ design fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. Ref:- PWD(B)-2017, Page no-68, Item no-40

50

49100

-

... More
Supplying, fitting & fixing 1st quality glazed Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m. Coloured decorative. In Wall. (i) Ground floor Ref:- PWD(B)-2017, Page no-64, Item no-35(B)(b)(i) (a)(i)

60

65580

-

... More
(ii) First floor

160

175680

-

... More
(iii) Second floor

160

176480

-

... More
Supplying and laying true to line and level High Grip, Scratch resistant, Neutral to UV rays, Full Body Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness 7.0, Staining resistance: Class- 1, Water Absorption E 0.5%] & MOR 35N/sq.mm and Breaking strength 1500 N for Outdoor area of building e. g. Gang-way, Corridor, Driveway, Parking lots, Courtyards, Sloping ramps, Entrance lobbies, Patios, Portico etc. set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in- Charge. In Ground Floor: Sizes-300 mm x 300 mm x10 mm Ref:- PWD(B)-2017, Page no-281, Item no-2

36

28260

-

... More
Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness 7.0, Staining resistance: Class-1, Water Absorption E 0.5%], MOR 38N/sq.mm & Breaking strength 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge. In Ground Floor: Sizes-300 mm x 300 mm x15 mm Ref:- PWD(B)-2017, Page no-281, Item no-3

187

330616

-

... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] Ref:- PWD(B)-2017, Page no-54, Item no-17.

45

45270

-

... More
Wood work in the door frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, iron Butt Hinges and M.S clamps. (The quantum should be corrected upto three decimals). (e) Sal: Malaysian Ref:- PWD(B)-2017, Page no-114, Item no-1(e)

0.4

30228

-

... More
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf) Ref:- PWD(B)-2017, Page no-124, Item no-11(a)

20

53180

-

... More
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat (b) 40mm X 6mm, 200mm Length Ref:- PWD(B)-2017, Page no-140, Item no-4(b)

60

1500

-

... More
Providing and fixing IS:12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. Complete: 100x60x 2.50 mm. Ref:- CWD DSR- Vol-I, Page No-192 Item No-9.70.2.

36

3101

-

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (viii) 225mm long x 12mm dia. bolt. Ref:- PWD(B)-2017, Page no-145, Item no-26(viii)

34

3876

-

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod). (vii) 150 mm grip x 12 mm dia rod. Ref:- PWD(B)-2017, Page no-146, Item no-30(a)(vii)

18

1998

-

... More
(i) Door stopper.(Brass) Ref:- PWD(B)-2017, Page no-143, Item no-19(i)

17

1989

-

... More
i) Godrej Hydraulic door closer fitted and fixed complete. Ref:- PWD(B)-2017, Page no-143, Item no-23(ii)(a)

17

35088

-

... More
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers includingfitting & fixing complete. Ref:- PWD(B)-2017, Page no-143, Item no-16(b)

17

33218

-

... More
Supplying, fitting & fixing of 2-Track / 3-Track powder coated Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminiumalloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVCroller, EPDM gasket, maruti lock, screws etc. including labour chargesfor fitting & fixing of aluminium 2-track/3-track sliding window withfixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr.and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottomand Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kgper Mtr. and Interlock member @ 0.612 Kg per Mtr. Ref:- PWD(B)-2017, Page no-245, Item no-15

115

51520

-

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass. Ref:- PWD(B)-2017, Page no-243, Item no-9 (ii)

25

11700

-

... More
Providing and fixing two track/three track powder coated aluminum sliding door in 25mm series standard tubular sections of approved make having two/three glazed panels of appropriate size running on two / three seperate tracks in the channel conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including 5 mm thick coloured/tinted/smoke glas, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. All the panels shall be of appropriate size having overlaps as required and including all required beadings, clips, rollers, rubber gaskets, cleats,etc. complete and powder coating in approved shade and colour.( 25 series shutter-A section, Interlock , H section, 25mm series Frame-3track top & bottom) Ref:- Based on rate analysis.

102

1069572

-

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. xiv) 12mm thick coloured / tinted / toughened glass coforming to IS: 2553-1992 (Part-II) Ref:- PWD(B)-2017, Page no-243, Item no-9 (xiv)

31

127658

-

... More
Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. (a) Pre-laminated Colour. Ref:- PWD(B)-2017, Page no-129, Item no-19(b)

60

33720

-

... More
35 mm thick factory made Solid panel PVC Door shutter made out of single piece extruded solid PVC profiles, 5 mm (± 0.2mm) thick, having styles & rails (except lock rail) of size 95 mm x 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitred cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 8 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge. b) Factory made Single piece extruded PVC laker coated tapered profile door shutter of both side laminated wood grains decorative Finish. Ref:- PWD(B)-2017, Page no-131, Item no-22(b)

22

63184

-

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottomguide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsiblebracings properly rivetted and washered including 38mm steelrollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessaryholes, chasing etc. in walls, floors etc. and making good damages complete. (i) Ground floor Ref:- PWD(B)-2017, Page no-106, Item no-18

5

17010

-

... More
ii) 2nd floor

5

17351

-

... More
Rendering the interior surface of walls with white cement based putty(two coats - 1.5 mm thk.) Ground floor Ref:- PWD(B)-2017, Page no-198, Item no-5

500.98

61119

-

... More
i) First floor

473.74

58137

-

... More
ii) 2nd floor

433.58

53521

-

... More
iii) 3rd floor(Mumty)

99.34

12334

-

... More
Providing and applying interior grade Acrylic primer of approved quality and brand on new plastered surface to receive Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per direction of Engineer in charge in ground floor. Two coats with solvent based interior grade Acrylic primer and two coats of Plastic emulsion paint finishing with roller. b) Two Coats. (ii) Solvent based interior grade Acrylic Primer PWD(B)-2017, Pg-195 It-7(b)(2)

1117.64

54205

-

... More
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of SuperintendingEngineer) : (exept toilet) (Two coats) Luxury quality Ref:- PWD(B)-2017, Page no-201, Item no-4(2)

1117.64

78234

-

... More
Providing and applying Exterior grade Acrylic primer of approved quality and brand on new plastered surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,complete as per manufacturers specification and as per direction of Engineer in charge. (i) Ground Floor. Ref:- PWD(B)-2017, Page no-196, Item no-8(b)

74.4

3355

-

... More
(ii) First Floor

148

6779

-

... More
(iii) Second Floor

148

6884

-

... More
(iv) Roof

49.6

2377

-

... More
Protective and decorative Acrylic exterior emulsion paint of approved quality as per manufacturers specification and as per direction of engineer in charge to be applied over acrylic primer as required. The rate includes cost of material, labour,scafolding and all incidental charges but excluding the cost of primer in ground floor Two coats. (c) Super Protective 100% Acrylic Emulsion. (i) Ground Floor Ref:- PWD(B)-2017, Page no-197, Item no-17(c)

74.4

7216

-

... More
(ii) First Floor

148

14461

-

... More
(iii) Second Floor

148

14566

-

... More
(iv) Roof

48.6

4852

-

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ref:- PWD(B)-2017, Page no-200, Item no-1(a)

30

870

-

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ref:- PWD(B)-2017, Page no-200, Item no-1(a)

50

1900

-

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: a) On timber or plastered surface: iv) Two coats (with any shade except white) Ref:- PWD(B)-2017, Page no-200, Item no-2(A)a(iv)

50

4050

-

... More
b) On steel or other metal surface : (iv) Two coats (with any shade except white) Ref:- PWD(B)-2017, Page no-201, Item no-2(A)b(iv)

30

2370

-

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) Ref:- PWD(B)-2017, Page no-109, Item no-22

59

452943

-

... More
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc.fitted and fixed with necessary screws and lugs in ground floor. (ii)Grill weighing above 16 Kg./sq.mtr and above. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. Floor above 4th floor). (i) Ground floor. Ref:- PWD(B)-2017, Page no-104, Item no-13(ii)

1.8

12682

-

... More
(ii) First floor

1.2

8539

-

... More
iii) Second floor

1.2

8624

-

... More
M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mm x0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete) Ref:- PWD(B)-2017, Page no-165, Item no-17.

160

185440

-

... More
Supplying, fitting & fixing UPVC pipes A Type and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A)(i) 110mm dia pipes. B) UPVC Fittings. Ref:- PWD(B)-2017, Page no-213, Item no-21(A&B)

50

12550

-

... More
i) Bend 87.5degree

10

1600

-

... More
ii) Shoe

10

1110

-

... More
Providing and fixing at or near ground level precast cement concrete in kerbs (size: 410 mm x 310 mm x width 150 mm at bottom with circular nosing at top) (Nano kerb) of cement concreat M25 Grade without reinforcement, fixing as per approved pattern and setting in position at site after preparing the bed grade and slopes by laying Cement concrete with jhama khoa (1:4:8) as per specification and direction of Engineer-in- Charge including filling of joints with 10 mm thick cement morter (3:1) and back filling the vertical piece properly with earth duly compacted and curing the morter joints for atleast 3 days including cost and carriage of all materials complete. Ref:- PWD(B)-2017, Page no-228, Item no-7

50

47400

-

... More
80 mm thick interlocking designer concrete paver block M-40 grade formedium-traffic zone & utility cuts on arterial roads etc. as per IS: 15658-2006(over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices ofblocks with fine sand by brooming & subsequent watering including cost ofsand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge. Colour Decorative Ref:- PWD(B)-2017, Page no-286, Item no-31(ii).

250

396750

-

... More
Preforming Vertical Load Test on single pile in accordance with IS:2911 (Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design laod including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancilliary arrangements for setting up gauges, construction of suitable platforms, keeping the loads and dismantling etc. complete as per direction of the Eingineer-in-charge. (i) Testing load up to 100T Ref:- PWD(R)-2016, Pg-292,It-12.19(i)

1

47500

-

... More
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. (a) Span up to 12 Mtr Ref:- PWD SOR-2018, Page No-101, Item No-2A (a)

0.7

41182

-

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). a) With 0.5 mm thick sheet. Ref: PWD(B)-2017, Page No -82, Item no-14,a

45

40320

-

... More
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping). (A) 300 mm lapping each way. (a) With 0.71 mm sheet Ref:- PWD(B)2017, Page No-84, Item No-18(A)(a)

25

9850

-

... More
Supplying profiles of required section made of Aluminium Alloy Extrusion conforming to IS: 732-1983 and IS: 1285-1975; Anodised with required film thickness and specified colour/natural matt finished conforming to IS: 1868-1983 for fabrication of Structural Glazing, Curtain Wall formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-in-charge. ( Payment will be made on finished length of the work). 15 micron colour anodising Structural glazing /Curtain Wall. (i) Mulion & Transom (Weight @1.819 Kg per Meter) Ref:- PWD SOR-2018, Page No-248 Item No-19(i)

60

27780

-

... More
ii) Sub frame for fixing Glass (Weight @0.31 Kg per Meter) Ref:- PWD SOR-2018, Page No-248 Item No-19(ii)

60

4860

-

... More
Supplying Glazing Silicon of approved make and brand for fixing of Glass on Sub-frame as per direction of Engineer-in-charge forStructural Glazing/Curtain wall etc. Glazing Silicon for fixing Glass on Sub frame. Ref:- PWD SOR-2018, Page No-248, Item No-20

60

6720

-

... More
Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge. for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work. Ref:- PWD SOR-2018, Page No-248, Item No-21

60

3420

-

... More
Labour charge for fabrication and installation of structural Glazing/Curtain Wall made from annodized extruded allooy aluminium sections for the following units:-Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. Ref:- PWD SOR-2018, Page No-248 Item No-23

90

76500

-

... More
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II). (i) 6mm thick Ref:- PWD SOR-2018, Page No-248 Item No-24 (i)(ii)

90

86130

-

... More
Making V-groove line ( 12 mm wide,12 mm deep) in plastered surface. Ref:- PWD SOR-2018, Page No-192 Item No-4

251.4

1458

-

... More
Sanitary & Plumbing Work Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap Ref:- PWD SOR(S&P) 2017, Page No-79, Item No- 2(a)

3

4263

-

... More
Suppling, fitting and fixing Wall mounted water closet of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to Code No. 20061 or 92065 & Model Studio or Rubbic of Hindware or equivalent.) Ref:- PWD SOR(S&P) 2017, Page No-79, Item No- 5

8

31904

-

... More
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of proved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm Ref:- PWD SOR(S&P) 2017, Page No-80, Item No- 6(i)

11

31559

-

... More
Supplying, fitting and fixing dome shaped C.P. waste grating for urinals. (i) 32 mm Ref:- PWD SOR(S&P) 2017, Page No-46, Item No- 23(i)

11

1980

-

... More
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(a) E.W.C. (iv) Bestolite (solid type) white. Ref:- PWD SOR(S&P) 2017, Page No-81, Item No-10(a)(iv)

3

2145

-

... More
Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White. Ref:- PWD SOR(S&P) 2017, Page No-84, Item No-28(B)(b)

8

10392

-

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.i) Polythene Flush Pipe. Ref:- PWD SOR(S&P) 2017, Page No-81, Item No-11(i)

14

2170

-

... More
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one. Ref:- PWD SOR(S&P) 2017, Page No-81, Item No-12(a)

3

1242

-

... More
Supplying, fitting and fixing shower of approved brand and make. (c) Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model -Tropical / Sumthing Special of ESSCO or similar). Ref:- PWD SOR(S&P) 2017, Page No-4, Item No-3(c)

14

17192

-

... More
Supplying, fitting and fixing shower of approved brand and make. (b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand). Ref:- PWD SOR(S&P) 2017, Page No-4, Item No-3(b)

11

15532

-

... More
Supplying, fitting and fixing shower of approved brand and make. (d) Chromium plated Hand shower with Flexible Tube & fittings (Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar). Ref:- PWD SOR(S&P) 2017, Page No-4, Item No-3(d)

8

19120

-

... More
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. (iii) 630 mm X 450 mm size. Ref:- PWD SOR(S&P) 2017, Page No-41, Item No-1 (iii)

11

26785

-

... More
Supplying, fitting and fixing pedestal of approved make for wash basin (white) Ref:- PWD SOR(S&P) 2017, Page No-41, Item No- 3

11

16467

-

... More
Supplying, fitting and fixing of CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent). Ref:- PWD SOR(S&P) 2017, Page No-45, Item No- 19 (C)

11

9427

-

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. Ref:- PWD SOR(S&P) 2017, Page No-36, Item No- 2

3

3045

-

... More
Supplying, fitting and fixing concealed cistern of approved make with flash plate Cute/Loop/Shell/Nova (Code No. concealo-H(80mm Body sap code 508179 of Hindware or equivalent). Matt/Gloss. Ref:- PWD SOR(S&P) 2017, Page No-36, Item No- 4

8

59520

-

... More
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (ii) 750 mm long. Ref:- PWD SOR(S&P) 2017, Page No-43, Item No-10(ii)

15

885

-

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long. Ref: PWD SOR(S&P) 2017, Page No-43, item No- 9(iii).

30

3210

-

... More
Supplying, fitting and fixing C.P. chain and stay with rubber plug. (ii) 32 mm dia. of plug. Ref:- PWD SOR(S&P) 2017, Page No-43, Item No- 11(ii)

11

550

-

... More
Supplying, fitting and fixing C.P. Extension Pipe Ref:- PWD SOR(S&P) 2017, Page No-46, Item No- 20

20

2120

-

... More
Supplying, fitting and fixing C.P. Wall Flange. Ref:- PWD SOR(S&P) 2017, Page No-46, Item No- 22

20

1280

-

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately). PVC Pipes .(a) For Exposed Work. (i) 20mm dia Ref:- PWD SOR(S&P) 2017, Page No-12, item No- 19(I)

30

3870

-

... More
(iii) 50mm dia

60

23040

-

... More
(b) For Concealed Work. (i) 20mm dia

150

23700

-

... More
(ii) 25mm dia

40

8200

-

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes. (i) 50mm dia Ref:- PWD SOR(S&P) 2017, Page No-12, Item No- 19(II)

30

12090

-

... More
(ii) 65mm dia

20

13040

-

... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity Ref: PWD SOR(S&P) 2017, Page No-37, Item No- 6(d)

2

20868

-

... More
Labour for hoisting plastic water storage tank. Above 1500 litre upto 5000 litre capacity. Ref:- PWD SOR(S&P) 2017, Page No-37, Item No- 10(ii)(a)+(b)

2

740

-

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia. Ref: PWD SOR(S&P) 2017, Page No-38, Item No- 13

8

152

-

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Concealed Work CPVC Pipes Class-1,SDR-11). 20 mm Ref: PWD SOR(S&P) 2017, Page No-29, Item No- 1(b)(i)

60

10260

-

... More
Supply of UPVC pipes (B Type) conforming to IS-13592-1992.(i) Single Socketed 3 Meter Length 160mm dia Ref: PWD SOR(S&P) 2017, Page No-68, Item No- 23(A)

60

32760

-

... More
(ii) Double Socketed 3 Meter Length 160 mm dia

50

29900

-

... More
(iii) Single Socketed 1.8 Meter Length 110mm dia

40

11720

-

... More
(iv) Double Socketed 1.8 Meter Length 110mm dia

25

7925

-

... More
Supply of UPVC fittings conforming to IS-13592-1992.(i) Coupler.(a)110mm dia Ref: PWD SOR(S&P) 2017, Page No-70, Item No- 23(B)

20

1700

-

... More
(i) Coupler (b)160mm dia

25

6525

-

... More
(ii) Plain Tee (a)110mm dia

20

1700

-

... More
(ii) Plain Tee (a)160 mm dia

30

7860

-

... More
(iii) Door Tee (a)110mm dia

25

4875

-

... More
(iii) Door Tee (b)160mm dia

30

15420

-

... More
iv) Plain Y (a)110mm dia

30

6180

-

... More
iv) Plain Y (b)160mm dia

20

11660

-

... More
v) Bend 87.5º (a)110mm dia

30

3600

-

... More
v) Bend 87.5º (b)160mm dia

25

8450

-

... More
vi) Vent Cowl (a)110mm dia

12

396

-

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. (A) Above ground. (i) 110mm dia Ref: PWD SOR(S&P) 2017, Page No-74, Item No- 24(A)

20

1140

-

... More
(ii) 160mm dia

20

1320

-

... More
Labour for fitting and fixing U.P.V.C. pipes for below ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. (B) Under ground. (i) 110mm dia Ref: PWD SOR(S&P) 2017, Page No-74, Item No- 24(B)

45

3780

-

... More
(ii) 160mm dia

90

8370

-

... More
Supplying fitting fixing of peet's valve fulway gunmetal standard pattern best quality of approved brand bearing IS-Marking with fittings complete. (i) 20 mm dia medium quality Ref: PWD SOR(S&P) 2017, Page No-4, Item No- 4

20

13140

-

... More
ii) 32 mm dia medium quality

5

6290

-

... More
iii) 50 mm dia medium quality

15

35430

-

... More
Supplying fitting fixing of chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) Ref: PWD SOR(S&P) 2017, Page No-6, Item No- 7(a)(ii)

22

14498

-

... More
Supplying fitting fixing of chromium plated Bib Cock with wall flange (Equivalent to Code No. 5047 & Model - Florentine of Jaquar or similar brand). Ref: PWD SOR(S&P) 2017, Page No-6, Item No- 7(c)(ii)

22

18942

-

... More
Supplying fitting fixing of chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). Ref: PWD SOR(S&P) 2017, Page No-6, Item No- 7(d)(i)

25

20375

-

... More
Supplying fitting fixing of chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). Ref: PWD SOR(S&P) 2017, Page No-6, Item No- 7(d)(ii)

15

14295

-

... More
Supplying, fitting and fixing of Chromium plated Turn type single lever concealed Diverter with lever, tip ton knob and flange of approvedbrand and make. (i) Exposed Part:- (Model Code No.F2004703 of CERA or equivalent) Ref: PWD SOR(S&P) 2017, Page No-7, Item No- 7(h)(i)(ii)

8

8432

-

... More
(ii) Concealed Part:- (Model Code No. F4010105 of CERA or equivalent)

8

16272

-

... More
Supplying fitting fixing of approved quality CP. Over brass grating complete. 50mm dia. Ref: PWD SOR(S&P) 2017, Page No-46, Item No- 23(ii)

22

5588

-

... More
Supplying, fitting & fixing of liquid soap container of approved make a) Chromium plated Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 17(a)

11

4323

-

... More
Supplying, fitting and fixing soap holder. (b) Fibre glass Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 18(b)

11

638

-

... More
Supplying fitting fixing of towel rail. 25mm dia. And 750 mm long Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 22(iii)

22

10450

-

... More
Supplying, fitting and fixing glass shelf with aluminium guard rails. (a) Ordinary type with 5.5 mm sheet glass. (ii) 600 mm X 125 mm Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 16(a)(ii)

11

5280

-

... More
Supplying, fitting and fixing Tooth brush and Tumbler holder of approved make of size 140 mm X 65 mm . Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 20

11

3971

-

... More
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm Ref: PWD SOR(S&P) 2017, Page No-82, Item No- 19

11

6743

-

... More
Supplying, fitting and fixing of Chromium plated double coat Hook(Equivalent to Code No. 35761 & Model - KUBIX of Jaquar or similar). Ref: PWD SOR(S&P) 2017, Page No-4, Item No- 3(e)

22

11352

-

... More
Supplying, fitting and fixing SS toilet paper holder of approved make with wooden spindle as necessary. (iii) Recess roll type size 150 mm X 150 mm Ref:- PWD SOR(S&P) 2017, Page No-83, Item No- 23(iii)

11

4224

-

... More
Supplying fitting fixing C.I. Round grating. 150mm Ref: PWD SOR(S&P) 2017, Page No-67, Item No- 18(ii)

12

1020

-

... More
Supplying fitting fixing C.I. Round grating. 100mm Ref: PWD SOR(S&P) 2017, Page No-67, Item No- 18(i)

8

496

-

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. (i) With Pakur variety. Ref: PWD SOR(S&P) 2017, Page No-87, Item No- 1(i)

20

139740

-

... More
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i) 900 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make. (A) With Pakur variety. Ref: PWD SOR(S&P) 2017, Page No-87, Item No- 2(i)

3

34083

-

... More
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. For 100 users. A) With Pakur variety. Ref: PWD SOR(S&P) 2017, Page No-89, Item No- 3(v)(A)

1

108891

-

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. Ref: PWD SOR(S&P) 2017, Page No-89, Item No- 4

1

16137

-

... More
18% GST

18282615

3290870

-

... More
1% CESS

21573486

215735

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.