Gorkhaland Territorial Administration Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Gorkhaland Territorial Administration Tender

Works
Eprocure
Opening Date18 Aug 2020
Closing Date8 Sep 2020
Tender Amount₹ 23,17,151 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 32A, DP Legrand

6

-

414.74

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP Legrand

24

-

244.72

... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required

-

-

-

... More
a)2x1.5sqmm +1x1.5sqmm

490

-

131.38

... More
b)2x2.5sqmm + 1x1.5sqmm as ECC

300

-

153.27

... More
c) 2x4sqmm+1x2.5sqmm as ECC

270

-

191.91

... More
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes

-

-

-

... More
a) 2.5sqmm

96

-

7.73

... More
b) 4sqmm

48

-

9.02

... More
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish Average run 8 Mtr

74

-

1093.51

... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish

-

-

-

... More
a) On board

24

-

86.3

... More
b) Average run 7.5 mtrs.

24

-

998.2

... More
Supply & Fixing only LED T8 28W 4' light fitting directly on wall ceiling as to GS. Philips or sililar make with lamp etc as required.

24

-

928

... More
Supplying and fixing 250 V 5 Star Aeroking 50 1200mm Ceiling Fan,including supplying and fixing fan regulator, Havells make.

2

-

3613

... More
S&F decorative LED based wall bracket incl lamp and all accessories incl lamp 9 W LED retrofit as per choise of EIC

48

-

1600

... More
Earthing with 50mm dia Galvanised iron pipe 3.64mm thick x3mts long and 1x4SWG GI wire (1Mts long) 13mmx80mm dia GI bolts, double nuts, double washers incl. S&F 15mm dia GI pipe protection as to GS. By TATA Medium GI pipe for soft soil.

6

-

1962.91

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe

6

-

1178.52

... More
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.

6

-

683.93

... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages a) No 4 SWG

200.7

-

23.18

... More
PV Module Supplying, fixing, commissioning and testing solor Photo Voltaic Module 250Wp each 156mm Monocrystalline Silicon solar cells laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3mm tempered glass. connforming to IEC 61215(revised) specifications or equivalent National or International Standards . The power output of the module(s) under STC should be a minimum of 250 W. The operating voltage corresponding to the power output mentioned above should be 16.4 V. The open circuit voltage of the PV modules under STC should be at least 21.0 Volts. The terminal box IP 65 Protection level on the module should have a provision for opening for replacing module. Power Conditioning Unit (PCU). Supplying, fixing, commissioning and testing power conditioning unit consisting with PCU Switching elements MOSFET Type of Charger PWM with MPPT technology from Normal AC Output Power: 2.5KW; Maximum AC Output Power:2.5KW;;AC Output Voltage Range: 220V ~ 240V AC; AC Output Frequency 50Hz+3% DC Input Voltage Range ( Voc ): 22V ~ 50V DC;Peak Inverter Efficiency: 92%; Standby Power consumption: 1W Features:MPPT Function/Over Current Protection/Over Temperature Protection/Reverse Polarity Protection/Island..Package Includes: Power inverter and Power cord. (APC/Sukam/SMA/KACO/Exide) make

6

-

307485

... More
1% Labour Cess

1

-

22942



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.