Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Gorkhaland Territorial Administration Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date18 Jul 2024
Closing Date31 Jul 2024
Tender Amount₹ 23,56,409 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(II) Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety(a) 1:3:6 proportion

22.52

123675

5491.81

... More
Plumconcreteworkwith40%cement concretewith30mmdowngraded stonemetal and60%stoneboulderof size150mmandabove, placedin position as directed excluding shuttering if any. (i) (1:3:6) proportion

81.05

319130

3937.7

... More
Rubblemasonry incement (1:6)withharddressed stones fromapproved quarries and clean, coarse and washed sand including carriage of all materials to site(b) In building works

37.98

181737

4785.08

... More
OrdinaryCement concrete (mix1:1.5:3) withgraded stonechips (20mm nominal size)excludingshutteringandreinforcement ifany, ingroundfloor as per relevant IS codes.(ii ) River Bazree

21.6

155280

7188.93

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removalof looserust (ifnecessary),cuttingtorequisitelength,hookingand bending tocorrect shape, placing inproperpositionandbindingwith16 gaugeblackannealedwireat every intersection, completeasperdrawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel.I. SAIL/ TATA/RINL

2.03

155470

76586.26

... More
Hireandlabourchargesforshutteringwithcenteringandnecessarystaging upto4musingapprovedstoutpropsandthickhardwoodplanksofapproved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a)25mmto30mmthickwoodenshutteringasperdecision&directionof Engineer-In-Charge.

269.93

107448

398.06

... More
125mm. Thick brick work with1st class bricks in cement mortar (1:4) in ground floor.

141.28

145646

1030.91

... More
Brick work with 1st class bricks in cement mortar (1:4) (b) In superstructure, ground floor

3.8

31439

8273.48

... More
Plaster(towall, floor, ceilingetc.)withsandandcementmortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar. (a) 20 mm thick plaster

182.46

44795

245.51

... More
(a) M.S.or W.I. Ornamental grill of approved design joints continuouslyweldedwithM.S, W.I. Flats and bars of windows, railingetc. fittedandfixedwithnecessaryscrewsandlugsinground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.

2.52

30892

12258.85

... More
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974withnon-friction projectingtype,boxtypehinges,glazingclips, lugslockingbracket, handle plate etc, including hoisting in position, straightening if required, fixinglugsincementconcrete(1:2:4)withstonechips20 mmdowncuttingholesandmendinggooddamages tomatchwith existing surface complete in all respect excluding glazing. (b)Openablesteelwindowsasper ISsizeswithsidehungshutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]

15.75

41295

2621.96

... More
Woodwork in door andwindow frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exludingcostofconcrete,IronButtHingesandM.Sclamps.(Thequantumshould be correted upto three decimals). (c) Sal : Siliguri.

0.08

7812

97657.32

... More
Supplying, fittingandfixingM.S.clampsfordoorandwindowframemadeofflat bentbar,endbifurcatedwithnecessaryscrewsetc.bycementconcrete(1:2:4)as per direction. (Cost of concrete will be paid separately) (b) 40mm X 6mm, 200mm Length

12

371

30.99

... More
Panel shutters of door and window,as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (Incaseofnon-supply of single plank,penal rate of reduction of 20% wil be made) (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.

2.52

8640

3428.81

... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iii) 75 x 45 x 2.5mm.

12

758

63.17

... More
Anodised aluminiumbarrel / tower / socket bolt (full covered) of approved manufactured fromextrudedsectionconforming to I.S. 204/74 fittedand fixed with cadmium plated screws: (iii) 100mm long x 10mm dia. bolt.

4

262

65.54

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded sectionconforming to I.S. specification (I.S. 230/72) fittedand fixed complete: (v) 125 mm grip x 12 mm dia rod.

4

595

148.98

... More
Anodised aluminium Aldrop / Slidingbolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fittedand fixed complete. (i) 250mm x 16mm dia bolt.

2

560

280.07

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968&IS: 1161-1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabricationwithnecessarymetalarcweldingconformingtoIS:8161969&IS: 9595 using electrodes of approvedmake and brand conforming to IS:814-2004, haulage, hoisting and erection all complete. Therateincludes thecostof rolledsteel section, consumablessuch aselectrodes,gasandhirechargeofalltoolsandplantsandlabour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment tobemadeonthebasisofcalculatedweightof structural tubularmemebrsas specified inrelevent IScode in finishedwork. Payment forgusset,bracket,cleatmaybemadebyaddingtheactual weightofsuchitemswithweightof finishedstructuralmembers.The ratesareconsideredforaheightof erection8m. /2ndfloor level fromtheground.Add1.5%extraover therateforeachadditional floor or 4m. beyond the initial 8 m. or part thereof. i) For trusses spanning up to 12.00 m

2.34

208937

89289.66

... More
Galvanised corrugated iron sheet work (excluding the supportingframework)fittedandfixedwith10mm.diaJor Lhook-bolts, limpetandbitumenwashersandputtycomplete with150mm.endlapandonecorrugationminimumsidelap. (Payment tobemadeonareaof finishedwork)(GCIsheet to be supplied by contractor) (i) In Roof: b) With 0.63 mm thick sheet

164.41

133045

809.23

... More
Galvanised iron sheet ridging fittedwith necessary bolts, screws, washers etc complete.(225mm end lapping) (A) 300 mm lapping each way(b) With 0.63 mm sheet

15.51

7375

475.53

... More
Galvanised iron sheet eaves gutter fitted and fixed with necessary50mmX6mmM.Sflatbarclampsbent todesign, bolts,nuts,washersetc.complete.Eavesguttermadeof0.63 mm. sheets.(300mm End lapping) (a) 225 mm. wide gutter

31.02

12902

415.94

... More
G.I.Rainwaterspout75mm.Dia.And 600 to 750mm.Long supplied fitted and fixed complete with two coats of paint to both exposed portion.

8

1392

174

... More
Supplying, fitting & fixing UPVC pipe sA-Type and fittings conforming to IS:13592-1992withall necessary clamps nails, includingmakingholes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc ifnecessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete A) UPVC Pipes:(i) 75 mm. Dia.

14.91

3518

235.98

... More
Supplying, fitting & fixing UPVC pipe sA-Type and fittings conforming to IS:13592-1992withall necessary clamps nails, includingmakingholes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc ifnecessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) completed) Shoe (i) 75 mm. Dia.

4

390

97.73

... More
Wooden eaves board as per design, fitted and fixed complete: In ground floor Wooden eaves board as per design, fitted and fixed complete: In ground floor(b) 25mm thick

13.06

43254

3312.01

... More
ProvidingFalseCeilingmadewithframeworkofsteel tubeof40mmx20mmof not lessthan18gauge,thelongandcrosssectionwillbeweldedwitheachother 1000mm to 1200mmapart the entire frameworkwill be fixed inwall using rawlplug or gutties or screws etc. and suspended fromceilingwithM.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATEDP.V.CSection150mmx12mmx1.00mm(+/-0.01mm) of approvedquality and colourwill be fixedon the frame so that the entire frameworkwill not bevisible frombelowP.V.CSectionwill be fixedwith the framewiththehelpofselftappingsteelscrewsincludingallmaterialsandlabour charges including fitting,fixing the same andhoisting includingmending the damagesinallrespectandcostofpaintasrequiredasperdirectionofEngineerin-Charge . In ground floor.

99.2

172137

1735.26

... More
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)

182.46

26529

145.4

... More
Supplying and laying true to line and level Anti-Skid,FullBody,Homogeneous & Granula finish Vitrified Tiles conformingtoIS:15622-200 6&IS4457-2007 and testing shall be made in accordance withIS:13630[Non-modular sizes for tiles with Skid resistance0.5,Mohr's hardness5.0, Staining resistance: Class-1,Water Absorption:E0.5%],MOR35N/sq.mm in Internal area of building e.g.Toilet Block, Passage,Corridor,Accessible OpenTerraceetc.set in20 mm sand cement mortar(1:4) and 2 mm thick cement slurry at backside of tiles using cement@2.91Kg./Sqm o using Polymerised Adhesive (6mmthick layer applied directly ove rfinished artificial stone floor/Mosaic etc without any backing course) laid afte rapplication slurry using1.75Kg of cement per Sqm below mortar only, joints grouted with admixture o fwhite cement and colouring pigment to match with colour of tiles/epoxygroutmaterialsofapprovedmakeas directedandremovalofwaxcoatingof topsurfaceof tileswithwarmwaterand poa) InGroundFloor:Sizes-300mmx300mmx10mmwithbreakingstrength 1200 Nlishingthetilesusingsoftanddryclothuptomirrorfinishcompleteincluding thecostofmaterials,labourandallotherincidentalchargescompletetruetothe manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).

105.55

113969

1079.77

... More
B)Supplying & laying of approvedmakeandbrandofscratch proof, flexible & homogeneous P.V.C. Vinyle flooring conforming to IS:3462-1982 in required finish, fixedwith syntheticacrylicadhesiveafterpreparingthefloor, levelling& smothaningwhennecessarywith suitable putty, as per the design & instruction of the Engineer-in-charge. (ii) 1.5 mm thick (with stud / checkered)

32.53

19152

588.75

... More
Supplying, fitting&fixing1st qualityCeramic tiles inwalls and floors tomatchwith theexistingwork&4nos. of key stones (10mm) fixedwitharalditeat thebackof each tile& finishing the jointswithwhite cementmixedwithcolouring oxide if required to match the colour of tiles including rougheningof concrete surface, if necessaryorby synthetic adhesive & grout materials etc. (B) Wall WithSandCementMortar (1:3) 15mmthick&2mmthick cement slurry at back side of tiles using cement@2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative

47.61

71607

1504.05

... More
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/Acrylic emulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(b) Two Coats (b) Two Coats

120.95

6501

53.75

... More
Applying ExteriorgradeAcrylicprimerofapprovedqualityandbrand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsionpaint includingscrapingandpreparingthesurfacethroughly, completeaspermanufacturer'sspecificationandasperdirectionofthe EIC.(b) Two Coats

139.81

7664

54.82

... More
(b)Priming one coat on timber or plastered surface with syntheticoil boundprimerofapprovedqualityincludingsmootheningsurfacesbysand papering etc.

16.63

753

45.29

... More
(a)Primingonecoat on steel or other metal surface with synthetic oil bound primerofapprovedqualityincludingsmootheningsurfacesbysand papering etc.

40.95

1463

35.75

... More
(A)Paintingwithbest quality synthetic enamel paint of approved make and brandincludingsmootheningsurfacebysandpaperingetc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : (iv) Two coats (with any shade except white)

16.63

1625

97.73

... More
(A)Paintingwithbest qualitysyntheticenamel paint of approvedmake andbrandincludingsmootheningsurfacebysandpaperingetc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :(iv) Two coats (with any shade except white)

40.95

3904

95.34

... More
AcrylicDistemper to interior wall,ceilingwithacoatofsolventbased interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats

120.95

10234

84.62

... More
Protective and Decorative Acrylic exterior emulsionpaintofapproved quality, as permanufacturer's specification and as per direction of Engineer-in-Chargetobeappliedoveracrylicprimerasrequired.The rate includes cost ofmaterial, labour, scaffoldingandall incidental charges but excluding the cost of primer.b) Premium 100% Acrylic Emulsion

139.81

14162

101.3



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.