Gorkhaland Territorial Administration Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Gorkhaland Territorial Administration - GTA Tender
Civil And Construction
Building Construction
Eprocure
Opening Date8 Mar 2024
Closing Date21 Mar 2024
Tender Amount₹ 15,03,426
Costs
EMD
₹ 30,069Document Cost
₹ 1,005Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GTA_682523_2Bid Award Id
ViewTender No
. GTA/EE/BED/NIeT-48/2023-24 Dated-08.03.2024Tender Authority
Gorkhaland Territorial Administration ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work))with earth obtain from excavation of foundation..
16.6
1534
92.41
... More
(II) Cement concrete with 30 mm. down graded shingles excluding shuttering.N.B. VarietyIn ground floor .(a) 1:3:6 proportion.
18.17
119743
6590.18
... More
Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor).(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge.
242.34
97129
400.8
... More
Plum Concrete work with 40% cement concrete with 30mm down graded stone metal and 60% stone boulder of size 150mm and above, placed in position as directed excluding shuttering if any.
30
118944
3964.8
... More
Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
40
6198
154.97
... More
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes.(ii) River bazree.
18.17
156747
8626.73
... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.(a) For works in foundation, basement and up to roof of ground floor/up to 4m. Tor steel/Mild steel.SAIL/ TATA/RINL
2.14
203584
95132.81
... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
88.37
109321
1237.09
... More
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface].(ii) With 1:4 cement mortar .(b) 15 mm. thick plaster.
246.01
61923
251.71
... More
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals).(d)(f) Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak.
0.57
59471
104335.89
... More
Panel shutters of door and window, as per design (each panel consisting of single plank with out joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, panel rate of reduction of 20% will be made).(iii) 35mm.thick shutters with 19 mm. thick panel of size 30 to 45cm. (b) sishu,gamar,Champ,badam,bhola, mogra,Hallak,
19.29
44168
2289.69
... More
Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grill
10.8
33980
3146.35
... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete (In all floors for internal wall & upto 6m height for external wall ).(i) 3 mm. thick (weighing 7.4 kg/sq.m.).
9
5986
665.15
... More
(a) M.S or W.I. Ornamental grill of approved design joints continuously welded ii) Grill weighing above 10 Kg./sq.m. and upto 16 Kg./sq.m.
0.85
12504
14710.63
... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design, direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considere
1.1
121570
110518.47
... More
Galvanized corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugaion minimum side lap. ( payment to be made on area of finished work). (GCI sheet to be supplied by contractor). (b) With 0.63 mm.thick sheet. .
76.5
86917
1136.18
... More
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c )consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value 0.65 should be placed in the Grid module to form a False Ceiling. All
complete as per the drawing & directions of Engineer-in-charge.a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U-
In ground floor.
55.76
109730
1967.9
... More
supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately).(a) 40mm x 6mm, 250mm Length
4
171
42.9
... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(ii) 50 mm x 40 mm x 2.5 mm.
4
268
67.22
... More
Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:.(iii) 100 mm long x 10 mm dia. bolt.
4
314
78.66
... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.(a) With continuous plate base (hexagonal/round rod).(ii) 100 mm grip x 10 mm dia rod .
2
294
147.31
... More
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S.205/66) and fitted and fixed with cadmium plated screws:.
4
303
75.8
... More
Supplying and laying true to line and level vitrified tiles of
approved brand (size not less than 600 mm X 600 mm X 10
mm thick) in floor, skirting etc. set in 20 mm sand cement
mortar (1:4) and 2 mm thick cement slurry back side of tiles
using cement @ 2.91Kg./sqM(B) Light Colour
7.8
14434
1850.63
... More
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
37.08
1803
48.63
... More
Wooden eaves board as per design, fitted and fixed complete:In ground floor (i) Plain eaves board (Local Sal)(b) 25mm thick
5.4
13955
2584.3
... More
Pre- painted Galvenized iron sheet ridging 300 mm lap each way and fitted with necessary bolts , screws , washers etc complete. a) with 0.63 mm sheet
12.26
6995
570.63
... More
Galvanized iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm.M.S.flat bar clamps bent to design, bolts. Nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping).(a) 225 mm. wide gutter.
24.52
12238
499.13
... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete.(A) UPVC PIPES.(ii) 110mm Dia.
25.2
9406
373.27
... More
(A) UPVC Fittings (ii) 110mm Dia.Bend 87.5
4
840
210.23
... More
(A) UPVC Fittings (ii) 110mm Dia.Bend 87.5
5
872
174.48
... More
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
4.2
228
54.35
... More
((A) Painting with best quality synthetic enamel paint of approved make and brand including smothning surface by sand papering etc. including using of approved putty etc on gthe surface , if necessary.(a) On timbered or plasterd surfaces , two coats.
4.2
474
112.98
... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
10.8
463
42.9
... More
(A) Painting with best quality synthetic enamel paint of approved make
and brand including smoothening surface by sand papering etc. including
using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface :iv) Two coats (with any shades except white)
10.8
1266
117.27
... More
Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)
191.48
33409
174.48
... More
Arcylic Distemper to interior wall ceiling with a coat of solvent based interior grade acrylic primer including cleaning and smothening of surface.(a) Two coats
191.48
19442
101.54
... More
Protective and decorative Acrylic exterior emulsion paint of approved quality , as per manufacture specification as per direction of EIC to be apply over Acrylic primer as required. the rate included cost of material , labour scaffoldic and all incidential charges but excluding the cost of primer.In ground floor ( two coat).(a) Normal Acrylic emulaion.
147.04
14304
97.28
Evaluation Notes How It Works ?