Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Gorkhaland Territorial Administration Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 Oct 2024
Closing Date8 Nov 2024
Tender Amount₹ 28,99,530 
Notes
Download

Costs

Summary

Gta/dwo/ Bcw/ Niet-04(sl No 14)/2024-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(a) With earth obtained from excavation of foundation.

15.44

77

1197.22

... More
Stone Boulder 150mm of N. Bengal variety

26.19

1272

33313.68

... More
Laying 150 mm. to 200 mm. boulder soling including rough dressing hand packing and ramming down small pieces in the interstics without rolling but including ramming.

102.47

50

5123.5

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or infoundation or in foundation trenches.

30.42

28

876.1

... More
(I) Cement concrete with graded stone ballast (40 mm size) excluding shuttering.In ground floor.

-

-

-

... More
(B) With N.B variety stone metal.(a) 1:3:6 proportion.

14.24

5971

85029.89

... More
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes.

-

-

-

... More
(ii) River bazree.

24.41

7238

176689.34

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.

-

-

-

... More
(a) For works in foundation, basement and up to roof of ground floor/up to 4m. Tor steel/Mild steel.SAIL/ TATA/RINL

1.92

79822

153259.78

... More
Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams, columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor).

-

-

-

... More
(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge. .

139.23

400

55803.38

... More
100 mm thick Autoclave aerated concrete block Work with size 625 mm x 250mm x 100 mm- Grade-I, having drying Shrinkage less than 0.05%conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS:3812-1981, with permissible loss on ignition upto 6%), lime , cement and laidin Cement Mortar (1:6) complete in all respect as per direction &satisfaction of Engineer-in-Charge .a) laid in Cement Mortar (1:6)-In Super Structure, Ground Floor.

147.72

727

107421.98

... More
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface].

-

-

-

... More
(ii) With 1:4 cement mortar .(a) 20 mm.thick plaster.

144.6

247

35745.12

... More
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface].

-

-

-

... More
(ii) With 1:4 cement mortar .

158.91

211

33561.79

... More
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.

14.31

40

583.85

... More
Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grill

-

-

-

... More
(b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only]

7.68

2640

20275.2

... More
(a) M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S., W.I. flats and bars for windows ,railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @1% for each addl. floor up to 4th floor and @1.25% for each addl. floor above 4th floor).

-

-

-

... More
(i) Grill weighing above 10 kg./sq.m.and up to 16kg/sq.m.

0.1

12343

1234.32

... More
(A) Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts,paints but including the cost of nails, screw etc.) (The quantum should be corrected up to three decimals).

-

-

-

... More
(ii) Sal :Local.

0.09

87622

7886.05

... More
supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately).

-

-

-

... More
(b) 40mm x 6mm, 200mm Length .

6

31

187.2

... More
Panel (made of single plank) of door and window shutters to design as directed:.in ground floor ( payment to be made on area of exposed new work ). ( in case of non-supply of single plank panel rate of reduction to a maximum of a 30% will be made).

-

-

-

... More
(iii) 25 mm thick panel of 30cm to 45cm width.(b) Ordinary Teak wood.

3.6

2055

7400.16

... More
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.

-

-

-

... More
(iv) 75 mm x 47 mm x 1.70 mm.

3

38

115.2

... More
Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:.

-

-

-

... More
(iii) 100 mm long x 10 mm dia. bolt.

2

66

132

... More
Anodise aluminium Aldrop/Sliding bolts of approved quality manufactured form extruded section conforming to I.S. specifictation (I.S.2681/66) fitted and fixed complete.

-

-

-

... More
(i) 250 mm x 16 mm dia. bolt .

1

282

282

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.

-

-

-

... More
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.(v) 125 mm grip x 12 mm dia rod.

2

150

300

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete (In all floors for internal wall & upto 6m height for external wall ).

-

-

-

... More
(i) 3 mm. thick (weighing 7.4 kg/sq.m.).

14.04

588

8255.52

... More
(b) Priming one coat on timber or plastered surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand papering etc. Door

3.6

45

164.16

... More
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

14.04

36

505.44

... More
Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)

303.51

146

44433.86

... More
Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to received distemper /Acrylic emulsion paint including scraping and preparing the surface thoroughly , complete as per manufactured specification and as per directions of the EIC.In ground floor.

-

-

-

... More
(a) one coat.(i) water based interior grade Acrylic primer.

303.51

37

11436.26

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same throughly (plastered or concrete surface) as per manufacturer's specification. In ground floor.

-

-

-

... More
(iii) Two coats.

303.51

58

17846.39

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.

-

-

-

... More
(a) On timber or plastered surface: (1) With super gloss (hi-gloss).(iv) Two coats (with any shade except white).

3.6

98

354.24

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.

-

-

-

... More
(b) On steel or other metal surface: (b) On steel or other metal surface: (iv) Two coats (with any shade except white).

14.04

86

1213.06

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design, direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considered for a height of erection 8m./ 2nd. floor leves from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part ther of.

-

-

-

... More
(i) For trusses spanning up to 12.00 m.

4.77

89904

428842.08

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150grams per sq. metre (followed by colour coated on both side) steel sheetwork having minimum yield strength of 550 Mpa of trapizoidal profile ofapproved make as per IS: 15965: 2012 and IS: 14246: 2013 (excludingthe supporting frame work) fitted and fixed with 55 mm & 25 mm selftapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc.complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work). In roof With .5mm thick sheet.

244.95

1087

266309.64

... More
Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way

-

-

-

... More
(b) With 0.91 mm sheet

9.5

576

5472

... More
Galvanized iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm.M.S.flat bar clamps bent to design, bolts. Nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping).

-

-

-

... More
(a) 225 mm. wide gutter.

31.8

418

13317.84

... More
P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm ofnot less than 18 gauge,the long and cross section will be welded with each other1000mm to 1200mm apart the entire framework will be fixed in wall usingrawlplug or gutties or screws etc. and suspended from ceiling with M.S flat19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm)of approved quality and colour will be fixed on the frame so that the entireframework will not be visible from below P.V.C Section will be fixed with theframe with the help of self tapping steel screws including all materials and labourcharges including fitting,fixing the same and hoisting including mending thedamages in all respect and cost of paint as required as per direction of Engineerin-Charge .In ground floor.

60.8

1747

106229.76

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete.

-

-

-

... More
(A) UPVC PIPES.

20

313

6264

... More
Construction of Kitchen and Toilet

-

-

-

... More
Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.

-

-

-

... More
(a) Depth of excavation not exceeding 1.500 mm.

27

119

3220.29

... More
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc.layer by layer complete .(payment to be made on the basis of measurement of finished quantity of work).

-

-

-

... More
(a) With earth obtained from excavation of foundation.

9

77

697.86

... More
Laying 150 mm. to 200 mm. boulder soling including rough dressing hand packing and ramming down small pieces in the interstics without rolling but including ramming.

34.59

50

1729.5

... More
Stone Boulder 150mm of N. Bengal variety

6.02

1272

7657.44

... More
(I) Cement concrete with graded stone ballast (40 mm size) excluding shuttering.In ground floor.

-

-

-

... More
(B) With N.B variety stone metal.(a) 1:3:6 proportion.

3.1

5971

18510.72

... More
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes.

-

-

-

... More
(ii) River bazree.

11.35

7238

82155.84

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction.

-

-

-

... More
(a) For works in foundation, basement and up to roof of ground floor/up to 4m. Tor steel/Mild steel.SAIL/ TATA/RINL

0.89

79822

71042.29

... More
Hire and labour charge for shuttering with centreing and necessary staging up to 4 m. using approved stout props and thick hard wood planks of approved thick ness with required bracing for concrete slabs, beams, columns, lintels curved or staight including fitting fixing and striking out after complection of works. (up to roof of ground floor).

-

-

-

... More
(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge. .

84.3

400

33787.44

... More
100 mm thick Autoclave aerated concrete block Work with size 625 mm x 250mm x 100 mm- Grade-I, having drying Shrinkage less than 0.05%conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS:3812-1981, with permissible loss on ignition upto 6%), lime , cement and laidin Cement Mortar (1:6) complete in all respect as per direction &satisfaction of Engineer-in-Charge .a) laid in Cement Mortar (1:6)-In Super Structure, Ground Floor.

52.09

727

37879.85

... More
100 mm thick Autoclave aerated concrete block Work with size 625 mm x 250mm x 100 mm- Grade-I, having drying Shrinkage less than 0.05%conforming to IS: 2185 (Part-3)-1984 made up of fly ash (conforming to IS:3812-1981, with permissible loss on ignition upto 6%), lime , cement and laidin Cement Mortar (1:6) complete in all respect as per direction &satisfaction of Engineer-in-Charge .a) laid in Cement Mortar (1:6)-In Super Structure, Ground Floor.

-

-

-

... More
(i) with 1:6 cement mortar.(b) 20 mm. thick plaster.

54.75

223

12220.2

... More
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface].

-

-

-

... More
(ii) With 1:4 cement mortar .(b) 15 mm. thick plaster.

54.82

211

11577.98

... More
M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design, direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considered for a height of erection 8m./ 2nd. floor leves from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part ther of.

-

-

-

... More
(i) For trusses spanning up to 12.00 m.

0.75

89904

67428

... More
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150grams per sq. metre (followed by colour coated on both side) steel sheetwork having minimum yield strength of 550 Mpa of trapizoidal profile ofapproved make as per IS: 15965: 2012 and IS: 14246: 2013 (excludingthe supporting frame work) fitted and fixed with 55 mm & 25 mm selftapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc.complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work). In roof With .5mm thick sheet.

19.67

1087

21385.22

... More
Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping).(A) 300 mm lapping each way

-

-

-

... More
(b) With 0.91 mm sheet

6.45

576

3715.2

... More
Galvanized iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm.M.S.flat bar clamps bent to design, bolts. Nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping).

-

-

-

... More
(a) 225 mm. wide gutter.

22.04

418

9230.35

... More
P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm ofnot less than 18 gauge,the long and cross section will be welded with each other1000mm to 1200mm apart the entire framework will be fixed in wall usingrawlplug or gutties or screws etc. and suspended from ceiling with M.S flat19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm)of approved quality and colour will be fixed on the frame so that the entireframework will not be visible from below P.V.C Section will be fixed with theframe with the help of self tapping steel screws including all materials and labourcharges including fitting,fixing the same and hoisting including mending thedamages in all respect and cost of paint as required as per direction of Engineerin-Charge .In ground floor.

2.99

1747

5224.13

... More
Supplying,Fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.

-

-

-

... More
(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20 Kg/Sq.m.

-

-

-

... More
(a) Area of each tile up to 0.09Sq.m.(ii) Other than Coloured decorative including white.

2.99

950

2841.7

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.Two Coats

54.82

85

4670.66

... More
Protective and decorative Acrylic exterior emulsion paint of approved quality , as per manufacture specification as per direction of EIC to be apply over Acrylic primer as required. the rate included cost of material , labour scaffoldic and all incidential charges but excluding the cost of primer.In ground floor ( two coat).

-

-

-

... More
(b) Premium 100% Acrylic emulsion.

55.38

102

5648.76

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.

-

-

-

... More
(a) On timber or plastered surface: (2)With other than hi gloss of approved quality.(iv) Two coats (with any shade except white).

5.67

90

510.3

... More
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.

-

-

-

... More
(b) On steel or other metal surface: (2)With other than hi gloss of approved quality.(iv) Two coats (with any shade except white).

6.48

86

559.87

... More
Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing).

-

-

-

... More
580 mm X 440 mm.

2

2129

4258.32

... More
Wash basin white vitreous china of approved make (without fittings) supplied, fitted and fixed in position on 75mm X 75mm X 75mm wood blocks and C.I. Brackets including two coats of painting of C.I. Brackets.

-

-

-

... More
630 mm x 450 mm size.

2

3214

6428.4

... More
Supplying, fitting and fixing PVC pipes of approved make of of Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pi;es as per IS:1239 (Part-I) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting piles, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials. Payment for painting will be made seperately).

-

-

-

... More
For Exposed Work PVC Pipes.

10

311

3115.2

... More
Supplying, fitting and fixing PVC pipes of approved make of of Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI Pi;es as per IS:1239 (Part-I) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting piles, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials. Payment for painting will be made seperately).

10

208

2085.6

... More
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soiling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside( outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including, supplying, fitting and fixing one 560 mm dia. R.C.C. manhole cover of approved make with R.C.C slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary rreinforcement(upto 1%) and shuttering and necessary corbelling brick work(1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster(1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and remeval of surplus earth with all costs of labour and materials (excluding the cost of master trap only).

-

-

-

... More
900 mm X 750 mm(inside) chamber including fitting and fixing S.W. master trap of 150 mm dia. of approved make.With Bazree (N.B.Variety).(SAIL/TATA/RINL)

2

12372

24744

... More
Construction of Septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (4:1) including two 560 mm dia. R.C.C. manhloe cover of approved make supplied, fitted and fixied in the top slab with necessary fittings, 19 mm thick cement plaster(4:1) with neat cement finish to the internal surfaces and 12 mm thick plaster(4:1) to outside wall upto 200 mm below G.L. floor finished with 25 mm thick grey artificial stone including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavating earth in all sorts of soil, shoring, bailing and pumping out water as necessary, ramming, dressing the bed and refilling the sides of the tank with earth, removing spoils, fliing up the chamber with clear water, removing foreign materialsfrom the chamber and including constructing attached inspection pit as per approved dawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 5% by weight of cement, complete in all respect as per directon of Engineer-in-Charge.

-

-

-

... More
For 30 users.With Bazree (N.B.Variety).(SAIL/TATA/RINL)

1

67769

67769

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work(6:1) band all round and cement brick work(6:1) upto 0.90 metre from top with 19 mm thick cement plastering(4:1) to inside face upto the depth of cement brick work, 12 mm thick cement plaster(4:1) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal(50 mm to 63 mm size) including R.C.C. cover slab of designed thickness with cement concrete(4:2:1) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe conections, excavation of well including shoring, dewatering and remeving the excess earth from the premisis as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work(6:1) and 1.00 m. inside dia.(OTHER MANUFACTURES NOT SPECIFIED)

1

19008

19008

... More
Supplying fitting and fixing PVC pipes for underground work of apprpved of make Schedule 80(medium duty) conforming to ASTMD-1785 and threaded to match with G.I. Pipes as per IS:1239 (Part-I) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, long screw, reducing socket, reducing tee, short pkiece etc. fitted including cost of all materials, jointing materials cutting pipes, making threads, cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials. No separate payment will be made for accessories, specials.).

-

-

-

... More
PVC Pipes.

10

2423

24235.2

... More
Supplying, fitting and fixing Flat back urinal (half stall urinals) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.

-

-

-

... More
Corner urinal 440 mm X 345 mm X 250 mm.

1

1540

1540.44

... More
Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without integrated grill

-

-

-

... More
(b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only]

6.48

2640

17107.2

... More
(A) Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts,paints but including the cost of nails, screw etc.) (The quantum should be corrected up to three decimals).

-

-

-

... More
(ii) Sal :Local.

0.23

87622

20153.24

... More
supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately).

-

-

-

... More
(a) 40mm x 6mm, 250mm Length .

18

36

648

... More
Panel (made of single plank) of door and window shutters to design as directed:.in ground floor ( payment to be made on area of exposed new work ). ( in case of non-supply of single plank panel rate of reduction to a maximum of a 30% will be made).

-

-

-

... More
(iii) 25 mm thick panel of 30cm to 45cm width.(b) Ordinary Teak wood.

5.67

2055

11655.25

... More
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete (In all floors for internal wall & upto 6m height for external wall ).

-

-

-

... More
(i) 3 mm. thick (weighing 7.4 kg/sq.m.).

6.48

588

3810.24

... More
Add 18% GSt

1

405179

405179

... More
Add 1% labour cess

1

26561

26561

... More
Electrification Charges

1

216953

216953



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.