Food Corporation Of India Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Food Corporation Of India - FCI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Sep 2024
Closing Date3 Oct 2024
Tender Amount₹ 2,61,157 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required (a) 2 Module (75mmX75mm)

4

1192

298

... More
b) 8 Module (125mmX125mm)

1

454

454

... More
Supplying and fixing 25A modular AC motor statrer on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

2

1022

511

... More
Supplying and fixing of 3 pin 25A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

2

574

287

... More
Dismantling of 400 mm Wall fan cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers, reinstalling the same as required

10

2620

262

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 A switch

5

515

103

... More
(b) 3 pin 5/6 A socket outlet

7

854

122

... More
(c) 15/16 A switch

1

156

156

... More
S/I/T/C of (±) 100 mm cut out dia round recess mounted 6 watt LED down light luminaire with LED lamp illumination not less than 540 lumen, THD20%, PF 0.90, CRI 70% , 5700 CRT & Ingress Protection not less than 20 including driver in the existing opening of falls ceiling after removal of the existing fitting as per direction of Engineer-in charge.

8

7416

927

... More
Supply Installation Testing Commissioning of 400mm Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect.

2

6714

3357

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

1

393

393

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

2

738

369

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole

4

1024

256

... More
S/I/T/C of recess/Surface mounted 18 watt LED luminaire with LED lamp illumination not less than 3600 lumen, THD10%, PF 0.95, CRI 70%, 6500 CRT & Ingress Protection not less than 20 including driver in the existing opening of falls ceiling after removal of the existing fitting as per direction of Engineer-in charge.

17

43197

2541

... More
S & F of 240V 6 W LED strip light Driver often Removal of the exsisting fittings as per direction of engineer-in-charge.

5

2795

559

... More
Supply and fixing of220 V 5 metre length 6 watt per Metre LED strip light ingress protection IP65 with driver, connector fixed on wall/trass clour worm white, blue, red, green, CDL of engineer-in-charge.

10

19200

1920

... More
Supplying and installing following size of perforated Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(a) 225 mm width X 50 mm depth X 1.6 mm thickness

30

26850

895

... More
(b) 450 mm width X 50 mm depth X 2.0 mm thickness

25

33125

1325

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.(a) 225 mm width X 50 mm depth X 1.6 mm thickness

1

1694

1694

... More
(b) 450 mm width X 50 mm depth X 2.0 mm

2

5366

2683

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (a) 225 mm width X 50 mm depth X 1.6 mm thickness

1

1967

1967

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.(a) Upto 35 sq. mm (clamped with 1mm thick saddle)

105

4725

45

... More
(b) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS Metre flat clamp

105

9660

92

... More
(c)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm Metre MS flat clamp)

25

2875

115

... More
Dismantling and disconnection of PVC insulated old 3.5/4 core up to 150 sq. mm armoured cable from wall ceiling along with angle iron frame and reconnection the same as per direction of Engineer-in-charge

1

2689

2689

... More
Dismantling the 5.0 Hp 3 phase pump from base plate of the pump motor set,repairng with supplying and fixing of rubber bush,coupling etc,assembling the pump motor set,painting with 2 coats of synthetic enamalled paint,connection,testing & comissioning the same as per direction of Engineer-in-charge

2

10090

5045



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.