Eastern Railway Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Eastern Railway - ER Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date9 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 4,89,21,281 
Notes
Download

Costs

Summary

Provision Of Vrf Ac System And Replacement Of Overaged Ac Plant At Different Unit Brsh & Metro Building.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
"Drawing of LT cable in Concealed way through PF wall / structure / building wall etc.as per General specification. 'L' hook should be provided at approx. every half meter length. (L.T.Cable will be supplied by Railway)"

50

70

3500

... More
Cable laying through duct and refilling with sand and covering the duct as per General Specification.(L.T. Cable will be supplied by Railway)

150

77

11550

... More
"Cable laying upon existing cable tray with necessary binding/clamps etc. as per General Specification. (L.T. Cable will be supplied by Railway)"

150

35

5250

... More
"Supply of 4 core x 6 sq.mm., armoured, Copper cable, XLPE, FRLSH insulated, 1100V grade. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

460

1121

515660

... More
"Supply of 4 core x 10 sq.mm., armoured, Copper cable,FRLSH, XLPE insulated, 1100V grade. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

350

1815

635250

... More
Supply of 4 core x 16 sq.mm. , armoured, Copper cable, XLPE FRLSH insulated, 1100V grade.(PVC wire Make: Havells/Gloster/Polycab/RR Kabel/ KEI )

400

2798

1119200

... More
"Supply of 4 core x 25 sq.mm., armoured, Copper cable, XLPE FRLSH insulated, 1100V grade. ( Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

300

4569

1370700

... More
"Wiring of panel to outdoor unit connection using above Copper cables through suitable size PVC conduit pipes, bends, tees etc. and all other accessories. (Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

1510

195

294450

... More
"Supply, fixing and commissioning of 1 Ph. MCB DB 8 Way complete with MCB DP 32A, 12 B/Cap 10kA - 1 No. and MCB SP 10A, B/cap - 10kA - 6 nos. along with Incomming & Outgoing connection etc. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand)"

22

2299

50578

... More
"Supply of 1 Phase, [2+4] way Distribution Board (Single door, Prewired type) comprising of the following: a) MCB SPN 32A, B/Cap - 10 kA - 1 No. b) MCB SP 10/20A, B/Cap - 10 kA - 4 Nos. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand)" 14

6

2871

17226

... More
Fixing of the above 1 Ph. Distribution Board by necessary fixtures.

6

178

1068

... More
"Supply of MS fabricated, hinged type floor mounted LT cubicle panel board made of (14 SWG) MS sheet duly powder coated, comprising with the following :- a) MCCB 320-400A, 4 pole, b/cap 50KA - 2nos.(incomer) b) MCCB 160-200A,4 pole B/Cap-50kA-2 nos. c) MCCB 100-125A, 4 pole, 15 b/cap. 36KA - 6 nos., d)Copper busbar - 600A 4 bar type - 1 set, LT CT operated multifunction energy meter,3 ph,-2 nos. including internal electrical connection with suitable size of wire / bar and provision of digital type ammeters & voltmeters with CT and modular LED indicators etc. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) (Meter Make: Selec/Secure/Lauritz Knudsen/ HPL/ Schneider) "

3

371200

1113600

... More
Installation, commissioning and testing of the above panel board with transportation charges.

3

7671

23013

... More
"Supply of outdoor type Double door Pillar Box comprising of the following: a) MCCB 320-400A, 4 pole, b/cap 50KA - 2nos.(incomer) b)MCCB 160-200A,4 pole B/Cap-50kA-2 nos. c) MCCB 17 100-125A, 4 pole, b/cap. 36KA - 6 nos., d)Copper busbar - 600A 4 bar type - 1 set, Along with internal connection by suitable size copper bars /wires with copper socketing. MS Pillar box completed with 4 legs and RCC foundation including LED indication lamp etc. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) " 18

2

349820

699640

... More
Installation, commissioning and testing of Pillar box including transportation charges.

2

7664

15328

... More
"Wiring of main with 6 mm2. , PVC insulated 1100V grade FRLSH single core, M/Strand 19 copper wire through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way along with ECC of 1no. 2.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI )"

200

163

32600

... More
"Wiring of Sub-main with 4 mm2. , PVC insulated 1100V grade FRLSH single core, 20 M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way along with ECC of 1no. 2.5 sq.mm., PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

750

160

120000

... More
"Supply and installation of GI Standard Earth pipe, 40 mm dia, 2000 mm long ,medium 21 gauge complete with provision of Earth pit and there connection with 4 SWG GI wire as per Sr. DEE(G)/SDAH's Drg. No. SDAH/G/MISC/47 dt.21.11.2008(Alt-1). (G.I. Pipe Make: TATA/ Jindal / Bansal ) "

21

837

17577

... More
"Supply,installation of medium duty GI Earth pipe 50mm dia,3 mtr long including connection with 8 SWG GI wire. (G.I. Pipe Make: TATA/ Jindal / Bansal ) "

9

1007

9063

... More
Supply of G.I. strip of size 40 mm x 6 mm (thick) and fixing the same with the walls of building by grouting of suitable size bolts with nuts at 450 mm interval for earthing with necessary connection. G.I. strip to be separated from the wall with provision of suitable size insulator with the bolts.

-

-

23

... More
Supply of G.I. strip of size 25 mm x 3 mm (thick) and fixing the same with the walls by grouting of suitable size bolts with nuts at 450 mm interval for earthing with necessary connection. G.I. strip to be separated from the wall with provision of suitable size insulator with the bolts.

200

120

24000

... More
Supply, Installation, Testing & Commissioning of VRF outdoor unit equipped with Full Inverter driven highly efficient Top Discharge Air cooled Type Outdoor units equipped with Variable refrigerant flow unit ( Cooling Only ), comprising compressor DC inverter driven Scroll/Twin Rotary compressors with fully factory charged Eco friendly refrigerent gas, running at 415V±10% - 3 Ph - 50 1 Hz with wide ambient operating range of -15 to 52 degrees(approx) Celsius in cooling mode. ODU's should have minimum 2 compresors above 18HP ODU in each module with backup option. The distance between Each Outdoor and furthest Indoor can able to handle piping length of 1000 meters total pipe length of Refrigerent pipe and height difference of 90 metre. Each VRF Indoors should have cordless/corded remote should have system automatically adjusts the evaporating temperature to match the room load, thereby optimizing both comfort and energy efficiency. (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

-

-

3696000

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended Medium pressure Static duct type Units 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 2 cordless remote ,blower section with blower suitable for cooling coil section with aluminium finned copper tubes cooling coil, filter sections with washable synthetic type air pre-filters, complete drain connection, inbuilt drain pump etc. complete of following capacities:- minimum 2.4 TR capacity (minimum cooling capacity minimum 8.4 KW, air flow not less than 790 CFM, sound pressure level will be maximum 37 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

14

40800

571200

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended Medium pressure Static duct type Units 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 3 cordless remote ,blower section with blower suitable for cooling coil section with aluminium finned copper tubes cooling coil, filter sections with washable synthetic type air pre-filters, complete drain connection, inbuilt drain pump etc. complete of following capacities:- minimum 3.2 TR capacity (minimum cooling capacity 11.2 KW, air flow not less than 1120 CFM, sound pressure level will be maximum 52 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

2

45921

91842

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 4 cordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 5.7 TR capacity (minimum cooling capacity 22.4 KW, air flow not less than 2500 CFM, sound pressure level will be maximum 62 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

2

80040

160080

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 5 cordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 16 TR capacity (minimum cooling capacity 56KW, air flow not less than 4940 CFM, sound pressure level will be maximum 61 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

4

190118

760472

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic 6 expansion valve, tubes,fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 0.8 TR capacity (minimum cooling capacity 2.8KW, air flow not less than 240 CFM, sound pressure level will be maximum 43 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

4

26550

106200

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic 7 expansion valve, tubes,fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 1.0 TR capacity (minimum cooling capacity 3.6KW, air flow not less than 349 CFM, sound pressure level will be maximum 45 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

4

27350

109400

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic 8 expansion valve, tubes,fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:-minimum 1.2 TR capacity (minimum cooling capacity 4.0KW, air flow not less than 349 CFM, sound pressure level will be maximum 45 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

2

27600

55200

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic 9 expansion valve, tubes,fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 1.5 TR capacity (minimum cooling capacity 5.6KW, air flow not less than 435 CFM, sound pressure level will be maximum 48 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

8

29390

235120

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic 10 expansion valve, tubes,fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 2.0 TR capacity (minimum cooling capacity 7.1KW, air flow not less than 660 CFM, sound pressure level will be maximum 49 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

4

30940

123760

... More
Supply, Installation, Testing & Commissioning of wall mounted High wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless 11 remote for sequential starting of blower fan / runner,coils, thermostat, pulse modulating electronic expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrossion. Minimum capacities of each Evaporative units are as follows complete of following capacities:-minimum 2.3 TR capacity (minimum cooling capacity 8KW, air flow not less than 700 CFM, sound pressure level will be maximum 47 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

2

38066

76132

... More
Supply, Installation, testing and commissioning of central controller (I-manager) / I. Touch central controller for monitoring & controlling all indoor & outdoor units centrally and can capable to control from Computer.

2

98000

196000

... More
Supply, Installation, Testing & Commissioning of Refrigeration Network (Refnet) joints per sets , Linear expansion valve with all necessary accessories. (1 set = 1 no. each for Gas + 1 no. each for liquid line) for Indoor Unit joints

40

4484

179360

... More
Supply installation of Interconnecting refrigerant pipe copper piping work with 14 thickness of (19mm/13 mm thick) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units & specifications, al l piping inside the room shall be properly supported with MS hanger / angle etc. as required.

-

-

758031

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 15 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 20 mm dia [RM = Running Meter]

72

121

8712

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 16 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 25 mm dia [RM=Running Meter]

96

126

12096

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 17 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 32 mm dia [RM=Running Meter]

150

148

22200

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 18 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 40 mm dia [RM=Running Meter]

40

170

6800

... More
Supply, installation, testing and commissioning of communication control wiring between indoor and outdoor unit (For VRV unit), as per the approved drawings and specifications. shielded communication cable size 3 Core X 1.5 mm2 [RM=Running Meter]

725

148

107300

... More
Supply, installation, balancing and commissioning of sheet metal GI site fabricated rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter dampers, 20 vanes, hangers, supports etc necessary supports using threaded road and anchor bolts, supply air collars, vanes, splitters grilles as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 24 Gauge GI Sheet

258

836

215688

... More
Supply, installation, balancing and commissioning of sheet metal GI Hand Made site fabricated rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter 21 dampers, vanes, hangers, supports etc necessary supports using threaded road and anchor bolts, supply air collars, vanes, splitters grilles as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 22 Gauge GI Sheet

86

1075

92450

... More
Thermal insulation material for Duct shall be non polar closed cell Elastomeric Nitrile 22 Rubber. It should be CFC free. Adhesive used for sealing the insulation shall be modified neoprene contact adhesive. It should have high water vapour resistance, good weathering properties and self extinguishing once dried strictly as per manufacturer's recommendations. Insulation material will be 13 mm thick Nitrile Sheet class-O

270

625

168750

... More
Providing and fixing of Duct acoustic lining with 10 mm thick open cell Nitrile Rubber sheet complete with adhesive and all accessory as required.

90

1136

102240

... More
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section supply air grills / square diffuser with volume control dampers as requied.

7

10752

75264

... More
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section return air grills / square diffuser without volume control dampers complete as required.

8

10154

81232

... More
Supplying, fixing, testing & commissioning of fresh air arrangement with volume control duct dampers, bird screen etc complete as required.

3

8850

26550

... More
Supply, erection, testing & commissioning of MS duct damper for controlling and balancing of air distribution.

3

7080

21240

... More
Supply, erection, testing & commissioning of MS non return damper in mouth connection for working and standby operation

4

10030

40120

... More
Supply, fabrication, installation and testing the flexible Canvas connections constructed of fire resistance flexible double canvas sleeve at Duct mouth.

16

1600

25600

... More
Refrigerant charge in entire VRF system including Nitrogen Flushing, charging of R410A or any eco friendly Gas for Topping Up, including Pressure testing & Vacuumizing . etc.

120

1000

120000

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 31 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 150 mm Wide & 50 mm Deep 1.6 mm thick. [RM=Running Meter]

250

330

82500

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 32 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 200 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

80

450

36000

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 33 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 300 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

155

688

106640

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 34 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 450 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

30

1010

30300

... More
"Supply, Installation, Testing & Commissioning of VRF outdoor unit equipped with Full Inverter driven highly efficient Top Discharge Air cooled Type Outdoor units equipped with Variable refrigerant flow unit ( Cooling Only ), comprising compressor DC inverter driven Scroll/Twin Rotary compressors with fully factory charged Eco friendly R-410A refrigerent gas, running at 415V±10% - 3 1 Ph - 50 Hz with wide ambient operating range of -15 to 54 degrees Celsius in cooling mode. ODU's should have minimum 2 compressors above 18HP ODU in each module with backup option. The distance between Each Outdoor and furthest Indoor can able to handle piping length of 1000 meters total pipe length of Refrigerent pipe and height difference of 90 metre. Each VRF Indoors should have cordless/corded remote should have system automatically adjusts the evaporating temperature to match the room load, thereby optimizing both comfort and energy efficiency. (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)"

-

-

11370788

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended Medium pressure Static duct type Units 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 2 cordless remote ,blower section with blower suitable for cooling coil section with aluminium finned copper tubes cooling coil, filter sections with washable synthetic type air pre-filters, complete drain connection, inbuilt drain pump etc. complete of following capacities:- minimum 2.4 TR capacity (minimum cooling capacity 8.4 KW, air flow not less than 790 CFM, sound pressure level will be maximum 37 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

45

40870

1839150

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended Medium pressure Static duct type Units 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 3 cordless remote ,blower section with blower suitable for cooling coil section with aluminium finned copper tubes cooling coil, filter sections with washable synthetic type air pre-filters, complete drain connection, inbuilt drain pump etc. complete of following capacities:- minimum 3.2 TR capacity (minimum cooling capacity 11.2 KW, air flow not less than 1120 CFM, sound pressure level will be maximum 52 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

1

45921

45921

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 4 cordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 6.4 TR capacity (minimum cooling capacity 22.4 KW, air flow not less than 2600 CFM, sound pressure level will be maximum 62 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

1

39200

39200

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 5 cordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 8.0 TR capacity (minimum cooling capacity 28KW, air flow not less than 2700 CFM, sound pressure level will be maximum 64 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

5

87100

435500

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure 6 Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible withcordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 11.4 TR capacity (minimum cooling capacity 40KW, air flow not less than 4400 CFM, sound pressure level will be maximum 66 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

16

181383

2902128

... More
Supply, Installation, Testing & Commissioning of Ceiling suspended High pressure Static duct type units, 230v / 1ph / 50 Hz, complete with microprocessor based panel, compatible with 7 cordless remote ,blower section with blower suitable for heating & cooling coil section with aluminium finned copper tubes cooling coil including filter sections with washable synthetic type air pre-filters, complete drain connection, drain pan etc. complete of following capacities:- minimum 16 TR capacity (minimum cooling capacity 56KW, air flow not less than 4940 CFM, sound pressure level will be maximum 68 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

6

190119

1140714

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic 8 expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:-minimum 0.8 TR capacity (minimum cooling capacity 2.8KW, air flow not less than 240 CFM, sound pressure level will be maximum 43 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

9

26550

238950

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic 9 expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 1.0 TR capacity (minimum cooling capacity 3.6KW, air flow not less than 349 CFM, sound pressure level will be maximum 45 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

14

27350

382900

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic 10 expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:-minimum 1.2 TR capacity (minimum cooling capacity 4.0 KW, air flow not less than 349 CFM, sound pressure level will be maximum 45 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

2

27600

55200

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic 11 expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 1.5 TR capacity (minimum cooling capacity 5.6KW, air flow not less than 435 CFM, sound pressure level will be maximum 48 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

10

29400

294000

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic 12 expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:-minimum 2.0 TR capacity (minimum cooling capacity 7.1KW, air flow not less than 660 CFM, sound pressure level will be maximum 49 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

16

30940

495040

... More
Supply, Installation, Testing & Commissioning of wall mounted Hi-wall units, 230v / 1ph / 50 Hz, complete with comprising of micro processor based side panel, compatible with cordless remote for sequential starting of blower fan / runner, coils, thermostat, pulse modulating electronic expansion valve, tubes, fins with specially factory coated hydrophilic treatment for heat & rust corrosion. Minimum capacities of each Evaporative units are as follows complete of following capacities:- minimum 2.3 TR capacity (minimum cooling capacity 8KW, air flow not less than 700 CFM, sound pressure level will be maximum 47 dB) (Make: Hitachi/ Daikin/ O General/ Mitsubishi / Carrier)

-

-

13

... More
Supply, Installation, Testing & Commissioning of Celing Suspended / Floor mounted Double skin construction Air Handling Unit with Mixing Chamber, Combination Filter at Suction (Pre filter, Fine Filter & Hepa Filter), Copper Cooling Coil Section with 6/8 RD DX Cooling Coil and SS304 14 Drain Tray, Fan Section with DIDW Centrifugal Blower with Backward Curved Impeller, Fan-Motor Mounting Base, Drive Motor with V-Belt Drive Package, Vibration Isolators and Fire Retardant Flexible Canvas Connector. Air Handling Unit shall have 50 mm thick Sandwich Insulated Panels with Thermal Break Profile with 0.6 MM thick Pre-Coated GSS Outer Skin and 0.6 MM Thick Plain GSS Inner Skin and with Extruded Aluminium Frame Structure. 15

-

-

2248396

... More
Supply & Fixing of Inline Fan for fresh air arrangement in AHU for OT & Cath Lab 16

-

-

18467

... More
Supplying, installing, testing and commissioning of 3 Stage Strip Heaters in AHU. 17

-

-

16200

... More
Supply & fixing of flow switch (AirStat) for heater safety in duct 18

2

4477

8954

... More
Supply & Fixing of Temperature & RH sensor with controller for OT/CATH Lab. 19

2

2980

5960

... More
Supply & Fixing of Temperature & RH display unit at OT/CATH Lab. 20

2

2980

5960

... More
Supply & Fixing of Magnehelic Guage for differential pressure at OT/CATH Lab

2

9263

18526

... More
Supply, Installation, testing & commissioning of centrifugal cabinet type fan section with Pre-filter (MERV 7), Microvee filter (MERV 13) for Fumigation facility

-

-

63460

... More
Providing & fixing of Electrical Starter Panel with VFD and Bypass starter arrangement 22 for AHU with suitable weather proof enclosure. The starter panel should have the facility for power supply & controlling to the Inline Fan, strip heater etc. Controller for auto changeover of DX ODU (1W+1S) operation. 23

3

55685

167055

... More
Supply & laying of copper flexible cable

-

-

31420

... More
Supply & Installation of Laminar flow plenum box with 16gauge aluminium boxing & 18gauge SS capsul shape perforation of follwing size along with Hepa filter section - 10 Nos.Plenum Size: 2400 x 1800 x 350mm Depth Filter: 90-100mm mini pleat filter

1

65805

65805

... More
Installation, testing and commissioning of central controller (I-manager) / I. Touch central controller for monitoring & controlling all indoor & outdoor units centrally and can capable to control from Computer.

2

59000

118000

... More
Supply, Installation, Testing & Commissioning of Refrigeration Network (Refnet) joints per sets , Linear expansion valve with all necessary accessories. (1 set = 1 no. each for Gas + 1 no. each for liquid line) for Indoor Unit joints

116

4484

520144

... More
Supply installation of Interconnecting refrigerant pipe copper piping work with 27 thickness of (19mm/13 mm thick) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor & outdoor units & specifications, al l piping inside the room shall be properly supported with MS hanger / angle etc. as required .

-

-

2179783

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 28 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 20 mm dia [RM=Running Meter]

220

121

26620

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required 25 mm dia [RM=Running Meter]

480

127

60960

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 30 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required - 32 mm dia [RM=Running Meter]

500

148

74000

... More
Supply, installation, testing and commissioning of PVC condensate drain pipes 31 wrapping with 9 mm thick nitrile rubber insulation. Drain water piping with Insulation, clamping, fitting, accessories, bends, elbows, tees, flanges, tappings, hangers, supports, accessories wherever required 40 mm dia [RM=Running Meter]

220

172

37840

... More
Supply, installation, testing and commissioning of communication control wiring between indoor and outdoor unit (For VRV unit), as per the approved drawings and specifications. shielded communication cable size 3 Core X 1.5 mm2 [RM=Running Meter]

1900

148

281200

... More
Supply, installation, testing and commissioning of communication control wiring between AHU and Panel, as per the approved drawings and specifications. shielded communication cable size 6 Core X 2.5 mm2 [RM=Running Meter]

200

224

44800

... More
Supply, installation, balancing and commissioning of sheet metal GI site fabricated 34 rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc necessary supports using threaded road and anchor bolts, supply air collars, vanes, splitters grilles as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required.Size 24gauge GI SHEET

1150

836

961400

... More
"Supply, installation, balancing and commissioning of sheet metal GI Hand Made site fabricated rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter 35 dampers, vanes, hangers, supports etc necessary supports using threaded road and anchor bolts, supply air collars, vanes, splitters grilles as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 22 Gauge GI Sheet"

250

1075

268750

... More
Supply, installation, balancing and commissioning of sheet metal aluminium site fabricated rectangular duct complete with al. flanges, neoprene rubber gaskets, elbows, splitter 36 dampers, vanes, hangers, supports etc necessary supports using threaded road and anchor bolts, supply air collars, vanes, splitters grilles and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 22 Gauge Aluminium Sheet

300

1741

522300

... More
Thermal insulation material for Duct shall be non polar closed cell Elastomeric Nitrile 37 Rubber. It should be CFC free. Adhesive used for sealing the insulation shall be modified neoprene contact adhesive. It should have high water vapour resistance, good weathering properties and self extinguishing once dried strictly. Insulation material will be 13 mm thick Nitrile Sheet class-O

1500

625

937500

... More
Thermal insulation material for Duct shall be non polar closed cell Elastomeric Nitrile 38 Rubber with anti microbial coating. Adhesive used for sealing the insulation shall be modified neoprene contact adhesive. It should have high water vapour resistance, good weathering properties and self extinguishing once dried strictly . Insulation material will be 19 mm thick Nitrile Sheet class-O and GC cloth pasted with UV protactive paints should be applied in outside exposed duct.

180

1547

278460

... More
Thermal insulation material for Duct shall be non polar closed cell Elastomeric Nitrile 39 Rubber with anti microbial coating. Adhesive used for sealing the insulation shall be modified neoprene contact adhesive. It should have high water vapour resistance, good weathering properties and self extinguishing once dried strictly. Insulation material will be 13 mm thick Nitrile Sheet class-O for inside duct.

220

872

191840

... More
Providing and fixing of Duct acoustic lining with 10 mm thick open cell Nitrile Rubber sheet complete with adhesive and all accessory as required.

300

1136

340800

... More
Supplying, fixing, testing & commissioning of powder coated extruded aluminium 41 section supply air grills / square diffuser with volume control dampers as requied.

36

10752

387072

... More
Supplying, fixing, testing & commissioning of power coated extruded aluminium section return air grills / square diffuser without volume control dampers complete as required.

40

10255

410200

... More
Supplying, fixing, testing & commissioning of fresh air arrangement with volume control duct dampers, bird screen etc complete as required.

20

8850

177000

... More
Supply, erection, testing & commissioning of MS duct damper for controlling and balancing of air distribution.

13

7080

92040

... More
Supply, erection, testing & commissioning of AL. duct damper for controlling and balancing of air distribution.

3

11210

33630

... More
Supply, fabrication, installation and testing the flexible Canvas connections constructed of fire resistance flexible double canvas sleeve at Duct mouth.

120

1770

212400

... More
Supply, erection, testing & commissioning of Motorised - Spring return type GI duct dampers

2

13570

27140

... More
Supply, fabrication, installation and testing of actuator - motorised spring return type for duct damper for controlling On/Off and power wiring. Control module shall be provided in each AHU. The entire damper & actuator assembly shall be tested.

3

17700

53100

... More
Refrigerant charge in entire VRV system including Nitrogen Flushing, charging of R410A ny eco friendly Gas for Topping Up, including Pressure testing & Vacuumizing . etc. .

425

1000

425000

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 50 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 150 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

700

338

236600

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 51 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 200 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

150

466

69900

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 52 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 300 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

450

690

310500

... More
Supply, fabrication, laying & fixing in positions with suitable GI angle supports of G.I. 53 perforated type Cable Tray for the entire HVAC workwith necessary bends, tees and clamps/couplers for fixing. All material shall be Hot dip galvanized as per Specifications. Size : 450 mm Wide & 50 mm Deep 1.6 mm thick [RM=Running Meter]

65

1033

67145

... More
"UNDER DECK INSULATION Supply & fixing of underdeck insulation in lower floor of OT to prevent sweating the floor with 19 mm thick Nitrile Sheet class-O Insulation. Adhesive used for sealing the insulation along with GI washer and nut bolt." [RM=Running Meter]

65

885

57525

... More
SITC of 4 body Modular Mortuary Cabinet , SS304 body, corrosion resistant, stainless 1 steel. The wall, ceiling & floor will be fabricated modular panels of 100% foamed polyurethane insulation , the blowing agent will be Cyclopentane which is zero ODP and foaming process should comply TUV standards & CCOE certification. Internal lighting will be waterproof CFL lamps, insulated multi doors are molded and stainless steel and externally locked, situated up front. Mortuary unit should be equipped with microprocessor based digital control panel to control temp between (+) 2 Deg. C to (+) 6 Deg C. The mounting in such, it necessarily breaks and conductivity of and between the inside evaporating and outside condensing unit is housed in an insulated compartment outside the chamber, factory assembled, pre- charged and tested for ready field installation. Capacity - 6000 BTUH appx, evaporator fan-800 cfm, evaporator coil-inner grooved copper tubes, 4 row, 8 FPI,Suitable eco-friendly Refrigerant gas.

2

971140

1942280

... More
"Supply of integrated LED tube light 4ft. luminaire, 1X20 W approx. (Extruded Aluminium LED Batten) (IP:20) (Indoor type) complete with tube and all accessories as per General Speciifcation. (LED Luminaries Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic)"

50

430

21500

... More
"Supply of LED luminaire 4ft., 2X18W or above (indoor type) including batten complete with all accessories as per General Speciifcation. (LED luminaires should conform to min IP:20 ) (LED Luminaries Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic)"

130

883

114790

... More
"Supply of Round Surface / Recess mounted LED Luminaire 12W complete with all accessories as per General Speciifcation. (LED Luminaries Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic)"

80

1112

88960

... More
Fixing, connection and commissioning of indoor LED tube light fittings/ round surface/recess mounted LED luminaires etc. with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc.

260

112

29120

... More
Supply of 2'X2' Surface/Recess mounted Luminaire 36W(approx) complete with all accessories as per General Speciifcation. (LED Luminaries Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic) 6

100

4505

450500

... More
Fixing charges for LED recess light fittings by necessary fixtures.

100

500

50000

... More
"Supply of LED Night lamp fittings with lamp complete with all accessories. (LED Luminaries Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic)"

30

582

17460

... More
"Supply of star rated BLDC Ceiling fan, 1200mm sweep, 3 blade (Blade material :High 8 grade Aluminium alloy),Service value:Minimum 7.5, 230V, 50 c/s,complete with all accessories as per General Specification.(Without Remote) (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/ Bajaj/Atomberg)"

60

2867

172020

... More
"Supply of mini Fan Regulator, rotary step,240V,50Hz,100W. (Make: Roma/ Panasonic/ Anchor/ GM Modular/ Legrand/ Havells )" 10

60

194

11640

... More
Fixing of Ceiling Fan & regulator with suitable clamping arrangement &'S' hook etc.

60

122

7320

... More
"Supply of AC Wall Bracket Fan,3 blades, 400mm sweep, approx 55W, 230V, 50Hz complete with all accessories. (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/ Bajaj)" 12

25

1663

41575

... More
Fixing of AC Bracket Fan with suitable G.I clamping arrangement.

25

126

3150

... More
"Wiring of Light, Fan points with 1.5 sq.mm., PVC insulated 1100V grade FRLSH single 13 core, M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/concealed way along with ECC of 1no. 1.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI ) (Switch & Plug Socket Make: Roma/ Panasonic/ Anchor/ GM Modular/ Legrand/ Havells)"

470

404

189880

... More
Extra over wiring cost for providing modular switches in Light / Fan point wiring.

-

-

14

... More
Wiring of 6 Amp Plug points with 1.5 sq.mm. , PVC FRLSH single core, M/Strand copper 15 wire through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way along with ECC of 1no. 1.5 sq.mm. PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI ) (Switch & Plug Socket Make: Roma/ Panasonic/ Anchor/ GM Modular/ Legrand/ Havells) 16

100

183

18300

... More
Extra over wiring cost for providing modular switches in 6A plug point wiring.

100

215

21500

... More
"Wiring of 16A / 6A power plug point with 4mm2 copper wire through PVC conduit pipe/casing/ concealed way. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI ) (Switch & Plug Socket Make: Roma/ Panasonic/ Anchor/ GM Modular/ Legrand/ Havells)"

50

512

25600

... More
Extra over wiring cost for providing modular switches in 16A/6A power plug point wiring.

50

251

12550

... More
"Wiring of Sub-main with 4 mm2. , PVC insulated 1100V grade FRLSH single core, 19 M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way along with ECC of 1no. 2.5 sq.mm., PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI )"

2500

160

400000

... More
"Wiring of Main/Sub-main with 6 mm2. , PVC insulated 1100V grade FRLSH single core, 20 M/Strand copper wire through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way along with ECC of 1no. 2.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI )"

500

163

81500

... More
"Supply of multi plug 16 modular board consisting of i) 10A multi plug socket-4nos,ii) 21 10A switch-4nos,iii)16A Multi plug socket-1no,iv) 16A switch-1nos,v) MCB SP 16A-1no. complete with all accessories including internal connection. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI ) (Switch & Plug Socket Make: Roma/ Panasonic/ Anchor/ GM Modular/ Legrand/ Havells) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) " 22

50

2596

129800

... More
Fixing and connection of above board alongwith switches etc. by necessary GI fixtures.

50

260

13000

... More
"Supply, fixing and commissioning of 1 Ph. MCB DB 8 Way complete with MCB DP 32A, B/Cap 10kA - 1 No. and MCB SP 10A, B/cap - 10kA - 6 nos. along with Incoming & Outgoing connection etc. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

5

2299

11495

... More
"Supply of 3 Phase,4 way distribution board (double door,IP:43, TP&N vertical type) comprising of the following : a) MCCB 50-63A,4 pole, B/cap:25KA - 1 no., b) MCB SP 6-32A B/cap - 10 KA - 12 nos. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

6

14466

86796

... More
"Supply of 3 Phase, 4 way distribution board (double door, IP:43, TP&N vertical 25 type)comprising of the following : a) MCCB 80-100A,4 pole, B/cap:25KA - 1 no., b) MCB SP 32A B/cap - 10 KA - 12 nos. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) " 26

8

18859

150872

... More
Fixing of the above 3 Ph. Distribution Board by necessary G. I. fixtures.

14

230

3220

... More
"Supply of star rated Geyser 10 ltrs complete with all accessories. (Make - Bajaj/ Venus/ Crompton/Havells/V-Guard/ AO Smith)""" 28

8

5165

41320

... More
Fixing of A. C. Geyser complete with necessary G.I. fixtures.

8

257

2056

... More
"Supply of MCCB 160-200 Amp., 4 pole, B/Cap. 36 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

2

26397

52794

... More
"Supply of MCCB 80-100 Amp., 4 poles, B/Cap. 25 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

2

10501

21002

... More
"Supply of MCCB 80-100 Amp., 3 poles, B/Cap. 25 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

-

-

31

... More
"Supply of MCCB 50-63 Amp., 3 poles, B/Cap. 25 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

2

7980

15960

... More
Supply of MCCB 250-320 Amps. 4 pole, B/Cap. 36 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand)

1

34945

34945

... More
"Supply of MCCB 320-400 Amps. 4 pole, B/Cap. 36 KA, 415 V. in metal enclosure. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ C&S/ Havells/ Legrand) "

1

34945

34945

... More
Survey, Planning, Design, Drawing and submission of layout of AC ODU & IDU etc prior to supply of materials and execution of work and after execution of work with energy audit report.

1

236000

236000

... More
2 Nos. 150 tr screw chiller complete with condenser/ chiller pump- motors , MS pipelines, valves, ceiling suspended AHU'S 12 nos, cooling tower 2 nos, electrical panel, cables etc (Location: Metro Building.) [Set = Lot]

1

-1103300

-1103300

... More
"Burn unit VRF - 2 Nos. 32 HP Outdoor Unit & connected Indoor Unit complete with its copper pipelines, & all accessories. (Location: Burn Unit /3rd Floor/OPD Bldg)" [Set = Lot]

1

-153400

-153400

... More
"Burn unit ductable complete 12 TR (1 no) indoor/outdoor complete with its copper pipelines, cables & all accessories. (Location: Burn Unit /3rd Floor/OPD Bldg)" [Set = Lot]

1

-53100

-53100

... More
"Eye OT: 8 nos 8.75 TR ductable AHU with its indoor/outdoor complete with its copper pipelines, cables & all accessories. (Location: Eye OT/1st Floor/Metro Bldg)" [Set = Lot]

1

-224200

-224200

... More
"Eye OT: 2 nos 8.75 tr ductable split LG make with its indoor/ outdoor complete with its copper pipelines, cables & all accessories. (Location: Eye OT/1st Floor/Metro Bldg)" [Set = Lot]

1

-53100

-53100

... More
"Central medical stores: Old 16 HP *3 outdoor complete with its 21 nos indoor complete with its copper pipelines, cables & all accessories. (Location: Medical Store)" [Set = Lot]

1

-177000

-177000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.