Eastern Railway Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Eastern Railway - ER Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date11 Feb 2025
Closing Date4 Mar 2025
Tender Amount₹ 43,53,155 
Notes
Download

Costs

Summary

Electrical General Work For Replacement Of Old & Overage Panel Interlocking Stations T

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Refrigerant Gas ( R410a ) Charging as per site requirements including installation, testing and commissioning.

18

870

15660

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 19.05 OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger and exposed piping shall be properly supported in cable tray. ( Make : Rajco / Mandev / Royku )

-

-

5

... More
Supply, installation, testing and commissioning of Interconnecting refrigerant pipe 6 work with 9.52 OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger and exposed piping shall be properly supported in cable tray. ( Make : Rajco / Mandev / Royku )

45

437

19665

... More
Supply of Copper Flexible cable of size 4.0 sq.mm. for control cabling between outdoor 7 and indoor units as per OEM specification bundled properly and neatly aligned with the refrigerant piping with well supported at specific intervals with fasteners including erection, testing and commissioning . ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton )

45

317

14265

... More
Supply of Copper Flexible cable of size 2C x 1.5 sq.mm. for control cabling between 8 outdoor and indoor units as per OEM specification bundled properly and neatly aligned with the refrigerant piping with well supported at specific intervals with fasteners including erection, testing and commissioning. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton )

90

127

11430

... More
Supply of Fabricated 22G GI ducting complete with gasket, supporting arrangement, hanger, nut, bolts with all other accessories including installation and commissioning of GI duct.

40

1182

47280

... More
Supply of Fabricated 24G GI ducting complete with gasket, supporting arrangement, hanger, nut, bolts with all other accessories including installation and commissioning of GI duct.

120

1182

141840

... More
Supply of Duct thermal insulation with 9mm thick aluminium foilfaced Nitrile Rubber pasted with adhesive including installation, testing and commissioning.

160

874

139840

... More
Supply of Duct acoustic lining with 12mm thick rigid board wrapped with RP tissue paper and finally with 26G Aluminium perforated sheet including installation, testing and commissioning.

60

966

57960

... More
Supply of Extruded Aluminium powder coated Supply & Return Air Grill / diffusers with GI Coller damper including installation, testing and commissioning.

1

9661

9661

... More
Supply of GI Duct damper made of 18 SWG GI Sheet including installation, testing and commissioning. 15

2

5705

11410

... More
Supply of Fuseable link Fire Damper including installation, testing and commissioning.

2

8557

17114

... More
Supply of Canvas connection at machine mouth including installation, testing and commissioning. 17

2

920

1840

... More
Supply of Back Draft Damper including installation, testing and commissioning.

2

3220

6440

... More
Supply of Sequential Timer Box for ductable units, consists with supply and fixing of 3 phase timer suitable to above mentioned AC Machine alongwith Double door TPN DB with 1 no. 32A 18 TP MCB as incomer and 1 no. 32A TP Power contractor with 2 NO + 2 NC auxiliary contact, 1 no. 24 Hrs. digital timer switch, 2 way auto manual bypass selection switch and 2 nos. indicating lamp with 1 no. 6A SP MCB for control circuit including necessary inter connection and earthing attachment for 3 phase AC machine ( For AC machines ) ( Make of MCB, Contactor, Timer etc. and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S / Havells )

1

12881

12881

... More
Minor Civil works like wall cutting, carpentry work such as enclosure for system components, PCC / RCC slab for outdoor units etc.

1

18402

18402

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Light point / Fan point / Call Bell point / Indication point / Glow Sign point by two nos. single core, HRFR / 20 FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase andneutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, ceiling rose and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

94

347

32618

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for 6A/5 pin plug point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, 21 PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

20

260

5200

... More
Conceal wiring on wall / ceiling / floor through PVC pipe of suitable diameter for 16A/6 pin plug point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS 22 grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

10

439

4390

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Window AC / Split AC / Water Cooler Point by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm., 1100V grade for 23 Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and each board comprising with one power unit which includes one double pole modular MCB, one single phase starter and one 25A socket and plug with indicating light similar to NORTH-WEST Cat.No.- ACPU 6M-BT or equivalent and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

4

894

3576

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for modular type Multi plug board consisting with three nos. 6A/5 pin modular plug socket, three nos. 6A modular switch, one no. 16A / 6 pin modular plug socket, one no.16A modular switch, one no.10A modular type MCB by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 24 2.5 sq.mm., 1100V grade for phase and neutral along with one no.single core, HRFR / FRLS 'grade, PVC insulated, copper conductor cable of size 1.5 sq.mm., 1100V grade for Earth Conti- nuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe, 'junction / circular box, modular switch, modular plug socket and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

10

1062

10620

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Submain by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one no. single core HRFR / FRLS grade, PVC insulated, 25 copper conductor cable of size 2.5 sq.mm., 1100V grade for Earth Continuity conductor including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

500

65

32500

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Main line 26 by two nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10.0sq.mm., 1100V grade for phase and neutral along with one no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

150

168

25200

... More
Conceal wiring on wall/ceiling/floor through PVC pipe of suitable diameter for Main line by 4 nos. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10.0 sq.mm., 1100V grade for 3 phases and one neutral along with one no. single core, HRFR / FRLS grade, PVC 27 insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for Earth Continuity Conductor ( ECC ) including supply of cable, GI concealed box with modular cover plate, PVC pipe and all other associated work along with make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / Bonton ) ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) )

100

791

79100

... More
Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway )

60

80

4800

... More
Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall ( LED Street light fitting will be supplied by Railway )

8

252

2016

... More
Fixing, connection and commissioning of BLDC Ceiling fan with suitable arrangement ( BLDC Ceiling Fan will be supplied by Railway )

20

64

1280

... More
Supply of Modular BLDC Exhaust Fan As per IS: 2312 (latest) Sweep Size - 250 mm, 31 White Colour, With Louver Shutter, Plastic Fiber body and all other accessories suitable for operation on 1Ph, 230V, 50Hz supply system. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj )

6

2946

17676

... More
Fixing, connection and commissioning of AC Exhaust Fan with suitable size and shape GI clamps / GI nut & bolts including necessary masonry work

6

223

1338

... More
Laying of cable underground through 100 mm diameter HDPE pipe by Micro Tunneling cable laying method including supply and jointing of HDPE pipe. ( Cable will be supplied by Railway )

1000

1593

1593000

... More
Trenching and laying of cable under ground by soil cutting with covering of cable by sand and bricks alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway )

400

160

64000

... More
Trenching, laying under road / track through 100 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway )

50

521

26050

... More
Drawing of cable on wall / structure with suitable size and shape GI clamps and commissioning of cable ( Cable will be supplied by Railway )

50

43

2150

... More
Supply of Auto Change Over Control and Distribution Panel Board of rating 60A, 1Ph, 37 240V, 50 Hz in 25 KV AC Traction System as per RDSO's specification no. - TI / SPC / PSI / CLS / 0023 or latest including installation, connection and commissioning of above panel alongwith terminal cable connection. ( Make : RDSO approved sources )

1

44463

44463

... More
Supply of Junction Box made of 14 SWG GI sheet of size 450 mm x 300 mm x 250 mm consisting with 2 nos. 63A porcelain fuse units (kitkats) conforming to IS:2086 -1993 complete with 38 hinged door with locking arrangement duly painted with two coats of paint after one coat of anti- corro- sive Red Oxide paint as per Sr. DEE/G/HWH's Drawing No. MISC / E / 2 / 05 including fixing, connection and commi- ssioning of above Junction Box on AT Mast with GI clamps made of GI flat of size 40mm x 6mm with GI nuts-bolts.

2

1198

2396

... More
Supply of MCCB, 4 Pole, ( 40 - 100 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short 39 Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication including metal enclosure, internal wiring, fixing, testing and commissioning. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S )

3

19472

58416

... More
Supply of SPN DB ( Metal Enclosure with Metal Door - IP 43 ), 6 way, 1Ph, 240V, 50Hz, 40 complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per require- ment of load and 1 no. DP RCBO of current rating 40A, 100mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribu- tion Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S / Havells )

4

5204

20816

... More
Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement.

4

132

528

... More
Supply of TPN MCB DB ( Metal Enclosure with Metal Door - IP43 ), 3Ph, 4 way per 42 phase, 415V, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz per phase as per requirement of load and 1 no. FP RCBO, of current rating 63A, 100mA, 10kA, 415V, 50Hz. ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S / Havells )

2

12652

25304

... More
Fixing, connection and commissioning of above TPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement.

2

131

262

... More
Supply of LT Wall Mounted/ Floor Mounted Cubical type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items : a) MCCB, 4 Pole, ( 63 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 2 nos. b) MCCB, 4 Pole, ( 25 - 63 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above mentioned features - 4 nos. c) Tinned Copper Busbar (4 44 Bar) each of capacity 200 Amps., 415V, 50 Hz. - 1 set. d) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 communication port having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 6 nos. e) CT of suitable ratio for MFM - 18 nos. f) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 12 nos. g) complete with petty stores, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Stelmec / HPL / Socomec / Anchor )

1

268732

268732

... More
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement.

1

13436

13436

... More
Supply of LT Wall Mounted/ Floor Mounted Cubical type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items : a) MCCB, 4 Pole, ( 63 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 1 no. b) Power contactor 4 pole, 415V, 100A similar to L&T model MCX22 or equivalent - 2 nos. c) Astro Time Switch, 2 module similar to L&T cat. AUTS02AST00 or equivalent - 2 nos. d) Tinned Copper Busbar (4 Bar) each of capacity 200 Amps., 415V, 50 Hz. - 1 set. e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 communication port having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. f) CT of suitable ratio for MFM - 3 nos. g) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 12 nos. h) Petty Store for cable gland, socket, fuse etc. - 1 job complete with all other accessories, internal wiring and fabrication work for above panel board. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Stelmec / HPL / Socomec / Anchor )

-

-

46

... More
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement.

1

17234

17234

... More
Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - 49 Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) 50

2

2737

5474

... More
Goods & Services Tax ( at present @ 18% )

1

664041

664041



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.