Eastern Coalfields Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Eastern Coalfields Limited - ECL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date16 Jan 2025
Closing Date1 Feb 2025
Tender Amount₹ 18,59,801
Costs
EMD
₹ 23,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ECL_325852_1Bid Award Id
ViewTender No
SLN/GM/AE(C)/E-Tender/24-25/76 dated 14.01.2025Tender Authority
Eastern Coalfields Limited ViewPurchaser Address
-Website
http://http://www.easterncoal.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
P/L damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
4.92
331
1626.87
... More
P/L in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
11.77
7386
86918.12
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
3.54
8764
31062.1
... More
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to foor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
7.93
9272
73480.6
... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
16
305
4880
... More
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
34.81
725
25248.13
... More
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
70.68
573
40516.74
... More
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
50.3
750
37750.15
... More
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
10.78
740
7986.97
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
1059.03
98
104738.07
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
1182.34
98
116933.43
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
10.55
7871
83071.11
... More
Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
50.33
892
44894.93
... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
0.08
66505
5320.44
... More
P/F ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
3.48
2718
9471.25
... More
P/F M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
223.26
187
41905.9
... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
74.87
491
36803.63
... More
P/F on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
14.6
287
4198.96
... More
P/F on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
4
112
450.8
... More
P/F on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
4
98
395
... More
P/F unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm
8
288
2307.6
... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
313.46
265
83112.59
... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
13.6
341
4645.75
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
70.56
150
10639.84
... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
127.8
146
18761.63
... More
P/F ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
2
341
682.5
... More
P/F ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
2
342
684.1
... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
2000
8
16400
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
392.94
134
53026.98
... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
40
527
21096
... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300 mm dia
50
1273
63670
... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 300 mm dia
50
1410
70515
... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
36.5
828
30231.13
... More
Supply & fixing of 4 SQMM 3 core PVC insulated copper wire
161
214
34503.91
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
6
2400
14400
... More
Wiring for circuit/submain wiring.....2x4sqmm+1x4sqmm earth wire
35
198
6940.5
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A
12
730
8760
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
6
317
1902
... More
Supplying and fixing 20W Tube light
8
400
3200
... More
Supply of nylon rope of dia 20 mm.
138
76
10521.12
... More
Supply and fixing submersible pump of 3 hp with specification of KSP4-3012 , kirloskar or other similar brand
1
38378
38378.84
... More
Supplying, fitting and fixing of UPVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTM D 1785 and threaded to match with G.I. Pipes as per IS:1239(part-1) with all necessary accessories and specials ( including cutting, making threads, fitting, fixing, trenching and refilling ect. complete in all respects as per the instructions of EIC)-Above Ground Works. 20mm dia
35
247
8674.05
... More
Supplying, fitting and fixing of UPVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTM D 1785 and threaded to match with G.I. Pipes as per IS:1239(part-1) with all necessary accessories and specials ( including cutting, making threads, fitting, fixing, trenching and refilling ect. complete in all respects as per the instructions of EIC)-Above Ground Works. 25mm dia
15
281
4217.55
... More
Supplying, fitting and fixing of UPVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTM D 1785 and threaded to match with G.I. Pipes as per IS:1239(part-1) with all necessary accessories and specials ( including cutting, making threads, fitting, fixing, trenching and refilling ect. complete in all respects as per the instructions of EIC)-Under Ground Works. 25mm dia
25
231
5775.5
... More
Supplying, fitting and fixing of UPVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTM D 1785 and threaded to match with G.I. Pipes as per IS:1239(part-1) with all necessary accessories and specials ( including cutting, making threads, fitting, fixing, trenching and refilling ect. complete in all respects as per the instructions of EIC)-Under Ground Works. 40mm dia
134
344
46181.76
... More
Providing & installation of solar DC pump 2HP with 6 nos Solar panels of not less than 325 watts, controller, sensor etc.
1
206400
206400
... More
Supplying and fixing Sheet steel 30/32 A Main Switches on flat iron frame on wall (240V DP with fuse on L&N) Havells
2
1277
2554
... More
Providing & laying polythene sheet 400 G
45.46
15
690.96
... More
Total impact of GST for the purpose of CTC
1
283698
283698.52
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements