Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Eastern Coalfields Limited - ECL Tender

Eprocure
Opening Date26 Sep 2019
Closing Date17 Oct 2019
Tender Amount₹ 3,99,385 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

3.38

18720

5538.6

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

4.84

28378

5863.25

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

14.41

101346

7033.1

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

5.8

41794

7204.7

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.

8.27

330

39.95

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars

580.13

43335

74.7

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform

39.76

22287

560.5

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)

86.32

17734

205.45

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)

54.32

13620

250.75

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

28.35

5298

186.9

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)

24.15

6534

270.6

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

7.5

1342

179

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

3.68

18809

5118.2

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate

27.5

10928

397.4

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

88.2

6072

68.85

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

12.43

1180

94.95

... More
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces

5.36

17487

3262.65

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

13.94

1346

96.65

... More
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)

64.52

4716

73.1

... More
Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime

72.77

2255

31

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

6.8

1609

236.65

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

6

1471

245.25

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend

2

190

95.4

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

14.4

6658

462.4

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

1.2

6050

5042.2

... More
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20 mm size PVC rigid conduit 'FR' (Precision make) including necessary fittings as required. 2x36/0. (2.5 sqmm) +1x22/0.3 (1.5 sqmm) ECC in 20 mm rigid conduit

40

5450

136.25

... More
Distribution wiring in 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20 mm size PVC rigid conduit 'FR' (Precision make) with 1x22/0.3 (1.5 sqmm single core stranded 'FR') for ECC including necessary fittings to light/fen/call bell point with piano key type switch (Anchor make) fixed on MS CRC sheet metal 16 SWG fabricated switch board cum JB with Perspex/bakelite top cover on wall in/c necessary connections and making earthing attachment and mending good damages to building works (PVC casing-capping and switch board both on surface) Average run 5 mtrs.

4

2590

647.5

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20 mm size PVC rigid conduit 'FR' (Precision make) with 1x22/0.3 (1.5 sqmm single core stranded 'FR') for ECC including necessary fittings to 5A 3 pin flush type plug socket & with piano key type switch (Anchor make) fixed on MS CRC sheet metal 16 SWG fabricated switch board cum JB with Perspex/bakelite top cover on wall in/c necessary connections and making earthing attachment and mending good damages to building works (PVC casing-capping and switch board both on surface) On Board

2

320

160

... More
Supply and fixing 205V 3 Pin 15A flush type Plug socket and 15A piano key type (Anchorbmake) switch on sheet metal box with baklite top cover and earthing attachment including S & F sheet metal box of size 175 mm x 100 mm (16 SWG) with 3 mm thick bakelite top cover.

2

704

352.35

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs long and 1x4 SWG GI (Hot Dip) wire (4 mtrs long) 13 mm dia x 80 mm long GI bolts, double nuts, double washers in/c S & F 15 mm dia GI pipe protection ( 1 mtr long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtr below the ground level & restoringb surface duly rammed as below For moorum soil by ISI - Medium GI Pipe

1

1777

1777.2

... More
Total impact of GST for the purpose of CTC

1

71896

71896.61



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.