District Magistrate Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
District Magistrate - DM Tender
Energy, Oil and Gas
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date31 Jan 2025
Closing Date14 Mar 2025
Tender Amount₹ 6,82,361
Costs
EMD
₹ 14,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_DMB_809658_1Tender No
18/2024-25/PS.Tender Authority
District Magistrate ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
ACDB Alternative current distribution box) ACDB box shall contais
a)Ambient-10 to 60 degree b) Type of enclosure:- IP66 poly carbonate materials
c) Input/Outputs- Single phase ACDB, 3 Phase DCDB
d) AC switching -MCCB/MCB based AC disconnection
e) Sugar protection- AC SPD type 2 Fuse with or without idication
f) Box/top cover- Opaque/transparent
1
18700
18700
... More
Supplying and fixing double door horrizontal TPN MCB distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good damages to original finish incl. inner connection with suitable size of copper wire and neutral link & provision for earthing attachment a) 4 way enclosure (607715)
1
2937
2937
... More
Supplying and fixing 240/415 V 63A MCB Isolator on din rail of existing DBs and necessary connection. For TPBN
1
870
870
... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
12
196
2352
... More
Supplying and fixing 240/415 V 125A MCB Isolator on din rail of existing DBs and necessary connection. For VTPBN
1
1135
1135
... More
Wire & cable (ISI standard)- Cables are designed for connecting photovoltic power supply system. Cable shall contain
a) Capacity- according to requiremments for Solar PV System
b)Rated Voltage- 0.6/1 Kva AC
c) Rated DC Voltage- 1.5KV
d) Working Voltage-DC 1000V
e) Insulation Resistance
f) 6mm cable single core (ISI Standard)
35
121
4235
... More
Wiring in 1.1 KV grade single core stranded FR PVC insulated & unsealthed copper wire of approved brand of following sizes in 25mm PVC casing-capping (Precision make) incl necessary PVC clips, fittings etc. a) 2X56/0.3 (10swmm) + 1X36/0.3 (2.5 sqmm) ECC (for AC machine)
10
360
3600
... More
Power conditioning unit:-
As SPV array produce direct current electricity, it is necessary to convert this direct current into alternating current and adjust the voltage levels to match the grid voltage. Conversion shall be achieved using an electronic inverter and the associated control and protection devices. All these components of the system are termed the "Power Conditioning Unit (PCU)". In addition the PCU shall also house MPPT (Maximum Power Point Tracker). Inverter output should be compatible with the grid frequency. Typical technical features of the inverter shall be as follows:-
Rated Power-230V 1 Phase 50Hz, Maz supported Panel Power-8000WP/*KW, Charge controller- MPPT, Nominal bank battery voltage-96V (supports 8/16 batteries) minimum batteries bank 1200 AH
Intelligent system with 32 bit DSP controller which enables it to handle multiple algorithms efficiently. Inbuilt MPPT charge controller extracts upto 30% more power from panels. Inbuilt isolation transformer to protect from grid surge and noise. Selectable source priority- Choose source priority from solar, battery and grid Userfriendy informative LCD display for time charging, supply etc. Dual MCB protection against short circuit protection for AC & DC. Safe for your home with comprehensive protection features such as short circuit, reverse polarity, battery over-charge and battery deep-discharge. Pure sine wave output for safety and noisless operation of connected appliances. withstand ambient temperature range 0 deg to 55 deg. withstand ambient humidity range 5% to 90% condensing. Includes system for surge protection. Lighting protection, earthing protection etc.
(Compliance to most of the National & International standars for safety and efficiency and reliabilty e.e. IEC 61683, IEC60068-1,2,14,30, IEC 60529 Microtech, Exide, Luminous)
1
108824
108824.7
... More
Battery- 12 V 100 AH Imla technology battery @C10 with futer DOD80% warranty 36 months the battery should be of 600 cycle life @60% DOD. Operating temperature 22-40 degree celcious as per IS 13369, 1992 standard ratings. Battery manufactured-supplied by the reputed Indian company.
12
8826
105912
... More
Earthing Installation – with Pipe Electrode :
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
4
1400
5600
... More
Thunder arrester-Lightning arrestor-0
The thunder or surge arrestor should be Gapless Metal Oxide type for outdoor purpose. It shall -
a) Rating (KV rms)-9
b) Degree protection-IP67
Arrestoe Rating- 4.5 Kv
Lighting impulse withstand voltage- 75KVP
1
6000
6000
... More
Distribution /layout junction box
1
3400
3400
... More
Add GST @ 18% (It 1-15)
1
103058
103058.39
... More
Add Cess @ 1% (It 1-16)
1
6756
6756.05
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%