Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
District Magistrate Tender
Civil And Construction
Building Construction
Eprocure
Opening Date6 Sep 2024
Closing Date13 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 5,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Emergency Repair And Renovation Of Ashram Hostel Building Attached To Maharajahat High School (hs) At Raiganj Block Under Uttar Dinajpur District
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DMUD_745757_1Bid Award Id
ViewTender No
32 of 2024-25Tender Authority
District Magistrate ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
4
-
-
Supplying, fitting and fixing towel rail with two brackets
(b) Aluminium
(ii) 25 mm dia. and 600 mm long
3
-
-
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.
(iii) 630 mm X 450 mm size
1
-
-
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
1
-
-
(e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent)
15 mm
12
-
-
Supply of UPVC pipe fittings:
(i) Coupler - 110 mm.
1
-
-
(ii) Bend 87.5º - 110 mm.
1
-
-
(iii) Vent Cowl - 110 mm.
1
-
-
(iv) W.C. Connector (450 mm long) W / lipring - 75 mm.
1
-
-
g) PTMT overhead shower ( Prayag or equivalent)
(ii) 150 mm round
4
-
-
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).
(A) PVC Pipes (Dia)
i) 15 mm
1
-
-
ii) 20 mm
10
-
-
iii) 40 mm
10
-
-
iv) 50 mm
30
-
-
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface]
Switch - Crabtree/ Havells/ Legrand make
Wire- KEI/ Havells/ Standard/ Polycab/ Finolex Make as per EIC
Average run 6 mtr
52
-
-
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on
surface]
Switch - Crabtree/ Havells/ Legrand make
Wire- KEI/ Havells/ Standard/ Polycab/ Finolex Make as per EIC
On Board
8
-
-
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
6
-
-
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
2
-
-
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI-Medium GI pipe
1
-
-
Supplying and fixing Sheet steel Main Switches on
flat iron frame on wall
30/32 A
240V DP with
fuse on L&N
Make- Havells
1
-
-
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
MAKE- HAVELLS/ STANDARD/ LEGRAND
2+6 way
1
-
-
2+12 way
1
-
-
Supplying and fixing 240/415 V MCB Isolator on
din rail of existing DBs and necessary connection.
MAKE- HAVELLS/ STANDARD/ LEGRAND
40A
2
-
-
Supplying and fixing 240/415 V MCB of Breaking
capacity 10kA & C characteristics on din rail of
existing DBs and necessary connection
SP- 6-32A
16
-
-
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
199.2
-
-
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
30
-
-
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works
20x10mm Size
229.2
-
-
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
26
-
-
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling
12
-
-
Fixing only lamp
12
-
-
Supply & Delivery of 9W Bulb
Make- Havells/ Crompton/ Bajaj
Model- NU Bulb Plus 9 W 865 B22 3 Star
12
-
-
Supply TMC501 Conventional industrial batten Philips/ Havells/ Crompton/ Bajaj industrial batten LED tube , model no:IGP161LT8-16 & LT8-20-865-(2))/ Philips (TMC 501 P 1xT-LED 22W P3242 & Mas LEDtube 18W, 2100lm 865 T8 (VE))
22
-
-
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl.
painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
10
-
-
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
10
-
-
Supply and delivery of Ceilling fan 48” Sweep
Orient Make/ USHA
10
-
-
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
30 cm (12")
4
-
-
Supply and delivery of 230V,50Hz Heavy duty Metal
12"exhuast fan.
4
-
-
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping
arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc
3
-
-
Supply & fixing 60 watt LED security light including necessary connection & accessories (40 mm dia GI pipe 1.5 mtr. Long with necessary clamp) Make- Philips/ Crompton TRP-409-60-57-SL-GL-NSG
3
-
-
Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1”X1” aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories
12
-
-
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and
painting
30
-
-
Supply and delivery of 2core 16sqmm aluminium armoured cable
30
-
-